Presentation is loading. Please wait.

Presentation is loading. Please wait.

Date of download: 9/27/2017 Copyright © ASME. All rights reserved.

Similar presentations


Presentation on theme: "Date of download: 9/27/2017 Copyright © ASME. All rights reserved."— Presentation transcript:

1 Date of download: 9/27/2017 Copyright © ASME. All rights reserved. From: Optimization of Pool Boiling Heat Sinks Including the Effects of Confinement in the Interfin Spaces J. Electron. Packag. 2008;130(4): doi: / Figure Legend: Longitudinal rectangular plate fin heat sink geometry with nomenclature

2 Date of download: 9/27/2017 Copyright © ASME. All rights reserved. From: Optimization of Pool Boiling Heat Sinks Including the Effects of Confinement in the Interfin Spaces J. Electron. Packag. 2008;130(4): doi: / Figure Legend: Sample contour plot of the temperature solution for a 0.7mm thick 10mm high aluminum fin with a base temperature 14°C above saturation

3 Date of download: 9/27/2017 Copyright © ASME. All rights reserved. From: Optimization of Pool Boiling Heat Sinks Including the Effects of Confinement in the Interfin Spaces J. Electron. Packag. 2008;130(4): doi: / Figure Legend: Experimental boiling curves for EDM aluminum heaters in saturated FC-72 at atmospheric pressure

4 Date of download: 9/27/2017 Copyright © ASME. All rights reserved. From: Optimization of Pool Boiling Heat Sinks Including the Effects of Confinement in the Interfin Spaces J. Electron. Packag. 2008;130(4): doi: / Figure Legend: Total heat sink heat dissipation for various fin configurations, 20×20mm2 base and EDM aluminum surface, in saturated FC-72 at atmospheric pressure

5 Date of download: 9/27/2017 Copyright © ASME. All rights reserved. From: Optimization of Pool Boiling Heat Sinks Including the Effects of Confinement in the Interfin Spaces J. Electron. Packag. 2008;130(4): doi: / Figure Legend: Loci of maxima of 20mm wide aluminum heat sink performance curves

6 Date of download: 9/27/2017 Copyright © ASME. All rights reserved. From: Optimization of Pool Boiling Heat Sinks Including the Effects of Confinement in the Interfin Spaces J. Electron. Packag. 2008;130(4): doi: / Figure Legend: Total heat sink heat dissipation as a function of the fin height for the optimized aluminum heat sinks in Table

7 Date of download: 9/27/2017 Copyright © ASME. All rights reserved. From: Optimization of Pool Boiling Heat Sinks Including the Effects of Confinement in the Interfin Spaces J. Electron. Packag. 2008;130(4): doi: / Figure Legend: Fin thickness trends for polished silicon heat sinks with 0.3mm fin spacing and 20mm sink length

8 Date of download: 9/27/2017 Copyright © ASME. All rights reserved. From: Optimization of Pool Boiling Heat Sinks Including the Effects of Confinement in the Interfin Spaces J. Electron. Packag. 2008;130(4): doi: / Figure Legend: Maximum base heat flux for 20mm long silicon heat sinks and the optimum fin thickness as a function of fin spacing

9 Date of download: 9/27/2017 Copyright © ASME. All rights reserved. From: Optimization of Pool Boiling Heat Sinks Including the Effects of Confinement in the Interfin Spaces J. Electron. Packag. 2008;130(4): doi: / Figure Legend: Single fin heat dissipation for 0.29mm thick aluminum and silicon fins, with base temperatures at the superheat corresponding to an unconfined pool boiling heat flux of 45kW∕m2 for each surface