3/02/2004 ab,az,ts Proto Front End Thermal Test Results 1 EFNI H K PACKAGED FRONT END COOLING TEST The Front Ends of the Outer Tracker are closely packed,

Similar presentations


Presentation on theme: "3/02/2004 ab,az,ts Proto Front End Thermal Test Results 1 EFNI H K PACKAGED FRONT END COOLING TEST The Front Ends of the Outer Tracker are closely packed,"— Presentation transcript:

1 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 1 EFNI H K PACKAGED FRONT END COOLING TEST The Front Ends of the Outer Tracker are closely packed, heat must be extracted with cooling water along the Aluminium cooling extension plate. For the test we use a cooling block with forced air Several sensors monitor heatup of components.

2 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 2 EFNI H K Good heat transport possible

3 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 3 EFNI H K Frame sideview

4 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 4 EFNI H K ASDBLR COOLING CONSTRUCTION

5 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 5 EFNI H K ASDBLR AS TEMPERATURE SENSOR ~750mV ~1.8mV/C We use a dummy input diode as temperature sensor (Not callibrated yet)

6 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 6 EFNI H K NTC 5K on Copper Surface Close to ASDBLR Each oard has a sensor Connection point

7 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 7 EFNI H K OTIS NTC NTC UNDER OTIS ON OPOSITE SIDE

8 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 8 EFNI H K NTC GRAPH

9 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 9 EFNI H K Proto Outer Tracker Front-End Tests 9 EFNI H K 35 C Otis 52 C ASDBLR NTC on copper 42C ASDBLR Input Diode 43C RESULTS AFTER SETTLING

10 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 10 EFNI H K 25 50 30 35 40 45 12 Hours COOLING BASE 6321 RED ASDBLR NTC ON Copper Board SURFACE 42C BASEPLATE THERMOMETER 35C t=0 >power on REMARKS: 1.forced air cooling base with regulators, shifts 10C 2.ASDBLR steps up 5C in 2 minutes, then settles to 7C above plate 3. OTIS settles 17C above cooling flap part of baseplate OTIS Copper NTC 52C BLUE ASDBLR DIODE ~43C ASDBLR 17C 8C FIRST IMPRESSION FROM PAPER RECORDERS AFTER POWER SWITCH ON

11 3/02/2004 ab,az,ts Proto Front End Thermal Test Results 11 EFNI H K FIRST CONCLUSIONS The ASDBLR has low temperature rise thanks to strong thermal coupling trough PCB Delta T=7 degrees C The maximum delta T is 17 degrees C for the Otis chip The regulators are mounted directly on the cooling plate, no internal sensor available, but adequate cooling is ok.


Download ppt "3/02/2004 ab,az,ts Proto Front End Thermal Test Results 1 EFNI H K PACKAGED FRONT END COOLING TEST The Front Ends of the Outer Tracker are closely packed,"