1 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 5 August 2014

2 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Claim report & problem analysis

3 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved.

4 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 3 Review usage range & limitations Description SRK10CNVSRK10CNSSRK10CNS-2SRK13CNVSRK13CNSSRK13CNS-2SRK19CNSSRK25CNSSRK10YLV-SSRK13YLV-S Cooling capacity (Kw)2.8 3.6 5.37.22.5-2.73.5-3.7 Cooling capacity (BTU/h) 9,554 12,283 18,084 24,566 8,530.0-9,212 11,942.0- 12,624 Power input (W) 0.77 1.00 1.50 2.12 0.21 - 0.88 0.21 - 1.24 Running current (A) 3.50 4.70 7.00 9.80 ̴ 3.30 ̴ 4.50 Size of liquid pipe (mm)6.35 (1/4") Size of gas pipe (mm)9.52 (3/8") 12.7 (1/2") 15.88 (5/8") 9.52 (3/8") Indoor temp (CWB)19 °C Indoor temp (CDB)27 °C Outdoor temp (CWB)24 °C Outdoor temp (CDB)35 °C Refrigerant typeR-22 R-410a Q'ty of refrigerant (Kg)0.58 Kg 0.86 Kg 1.25 Kg1.05 Kg0.70 Kg0.95 Kg Standard charging (g/m)10 g/m -- Standard pipe length (m)7.5 m 7.0 m 15 m Max. of pipe length (m)15 m 25 m 15 m Max. of height (m)5 m 15 m 10 m Voltage (V)± 10 % Frequency of cycle10 times/h 4 times/h ON - OFF interval3 min.

5 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 4 Review usage range & limitations

6 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 5 Review usage range & limitations

7 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved.

8 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 7 Protective control function

9 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 8 Protective control function

10 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved.

11 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 10 Troubleshooting procedure 1. Analysis data from customer. 2. Check protection control function & usage limitation range 3. Check error code / stop code / service mode 4. Check installation condition. 5. Check power supply & usage style of user 6. Turn off & check flap when power on 7. Prepare service tools & probable damaged parts 8. Check fuse & varistor 9. Check battery of remote control 10. Check sound emitted when turn unit by remote control

12 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Refrigeration system condenser compressor evaporator saturated vapor Saturation liquid expansion valve saturation liquid saturated vapor Indoor Outdoor Hot gas Hot liquid Cool liquid Cool gas

13 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Logic of EEV

14 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 13 Error code

15 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 14 Error code

16 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 15 Stop code (For service mode)

17 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 16 Stop code (For service mode)

18 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 17 Stop code (For service mode)

19 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 18 Stop code (For service mode)

20 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved.

21 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 20 Service tools Manifold Gauge FOR R-22 FOR R-410a

22 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved.Superheat For example : The temperature is 10deg. at C and 5deg. at B. The superheat temperature is 10deg. - 5deg. = 5deg. Superheat degree = Saturated vapor temperature – Measuring temperature In the following diagram, when pressure inside the evaporator is 0.84 MPa, the temperature is 5deg. A saturation state is reached between A and B with a temperature of 5deg. However, it is gas only between B and C. Therefore, the 30deg. Surrounding air emits heat to the gaseous refrigerant, making the refrigerant temperature rise (sensible heat), e.g to 10deg. The outlet temperature is slightly higher than that in the evaporator. Usage range 3 ͦͦͦ C ≤ SH ≤ 7 ͦͦͦ C

23 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 22 Service tools Thermo Meter

24 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 23 Service tools Multi Meter / Clam Meter / Mega Ohm tester

25 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 24 Service tools Refrigerant tank / Weight scale / Vacuum pump

26 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved.

27 © 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved.


Download ppt "© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 5 August 2014."