DIVISIONSPECIFICATION INPUT POWER DC 24V / 1.25A ※ Power supply from the floor distributor is not available. MAX POWER CONSUMPTION Max 30W VOICE CONVERSATION.

Similar presentations


Presentation on theme: "DIVISIONSPECIFICATION INPUT POWER DC 24V / 1.25A ※ Power supply from the floor distributor is not available. MAX POWER CONSUMPTION Max 30W VOICE CONVERSATION."— Presentation transcript:

1 DIVISIONSPECIFICATION INPUT POWER DC 24V / 1.25A ※ Power supply from the floor distributor is not available. MAX POWER CONSUMPTION Max 30W VOICE CONVERSATION TYPE HANDS FREE TYPE DATA COMMUNICATION TYPE RS-485 MONITOR SCREEN SIZE10.1 inch (COLOR DIGITAL LCD) LCD RESOLUTION800 (H) x 480(V) LCD BACK LIGHT LIFETIME 20000 HRS (LED type backlight) INTERFACETOUCH PANEL + SIDE BUTTON VIDEO OUTPUTNTSC / PAL TYPE INSTALLATIONFLUSH MOUNTED SHT-8610XM/EN Specification

2 SHT-8610XM/EN Magnetic sensor Door Camera Door lock Motion Detector Security Gas Sensor Fire Sensor Kitchen TVBathroom Phone Communication UTP 4P UTP 4P 2W 4W 3W 2W 4W Floor Distributor Building Distributor SHT-5181XL/EN SHT-552XS/EN Text Server UTP(4P) X2 UTP(4P) X 2 UTP(4P) X 2 2W Lighting Switch Air conditioner Gas valve controller Motorized Blind Control 2W Configuration CCTV 4W

3 SPEAKER USER INTERFACE CALL BUTTON MIC LED INDICATOR POWER STATUS COM. STATUS SECURITY MODE LED INDICATOR POWER STATUS COM. STATUS SECURITY MODE SIDE BUTTON 1.EMERGENCY CALL 2.STOP/RESTORE 3.AWAY/SECURE MODE 4.DOOR OPEN SIDE BUTTON 1.EMERGENCY CALL 2.STOP/RESTORE 3.AWAY/SECURE MODE 4.DOOR OPEN SHT-8610XM/EN Part name and Function

4 ※ This user interface and some functions can be changed. SHT-8610XM/EN Main Menu

5 ※ This user interface and some functions can be changed. Favorite : To select favorite menu Setting : To change setting values Time : This time is gained from Server Status : :MCU connection problem Status : :MCU connection problem Notice : Public notice or individual notice Visitor : To see the video of Visitor who visited when absent Memo : To see the memo left Elevator : Used to call the elevator (Optional) Door check : To monitor in front of the door Security : To set up the security mode Mute: Silent mode Delivery : To check the delivery arrival/receipt information (Optional) Help : To see the help SHT-8610XM/EN Sub Menu

6 6 zones Intrusion Detector Door Camera Air conditioner SHT- ESC1A1 Telephone Gas Valve Gas Sensor Emergency Switch Gas Valve Control module Lighting Switch Electric Curtain Kitchen TV Sub phone SDLGas Sensor Fire Sensor Motion Sensor Magnetic Sensor SHT-8610XM/EN Wiring Max 4 CCTV SHT-ZCT004/TW

7 1. Press the Setting incon on the start-up screen 2. Press [Reg No.] icon on the setting screen 3. Enter [#] + [*] + [0] + [0] in the Home Call No. section on the Registration Call number screen. 4. Network : Input home ID and Text noticer ID SHT-8610XM/EN SETTING

8

9 EZON Wiring Diagram (FD) UTP CAT5 x 1 * DATA & Voice Channel Floor Distributor 1st Floor 2nd Floor Main Controller Management & Guard Phone Lobby Phone Main Entrance VDA MODELSPEC SHT-ZFT04/CN 4 channel floor distributor SHT-ZFT10/CN10 channel floor distributor SHT-VD104 4 channel Video Distribution Amplifier SHT-VD110 10 channel Video Distribution Amplifier UTP CAT5 x 2 * 1 : Voice Channel & Lobby video * 2 : Data & ETC Coaxial Cable x 1 *Video channel Floor Distributor Overall Diagram #Voice: Max Wiring Distance 2km #Data: Max Wiring Distance 0.5Km 3nd Floor 4nd Floor

10 EZON Components CAMERA IR LED SPEAKER DISTANCE SENSOR 3.5” TFT LCD TOUCH KEY PAD 13.56MHz RF CARD READER MIC FUNCTIONSPECIFICATION COMMUNICATIONRS-485 POWERSHT-PS1250X, SHT-PS17X (DC12V, 2.5A) LCD3.5” Color TFT LCD (320x240) CAMERA 1/3 CCD, 270K PIXELS 6 IR LED FOR NIGHT AVAILABLE TO CHANGE THE ANGLE (15 DEGREE) CALL HOUSEHOLD CALL GUARDPHONE CALL AUTO-DOORNormal Open, Normal Close PASSWORDENTRANCE PASSWORD FOR EACH HOUSEHOLDS (max 1,000) CARD ACCESS13.56MHz RF CARD ACCESS CONTROL (max 4,000) Public Unit

11 EZON Components Public Unit ○ User Function FUNCTIONDescription Household Call 1.Press the unit number. (It is impossible to make a call to other building or blocks) 2.Press the call button 3.After receiving by the tenant, the call from lobby is accepted. 4.If the line is busy, the tenant is having a call with others. 5.If the tenant presses open button on the monitor, the door will be opened. 6.If the visitor presses [#] button, the call will be canceled. Guard room Call 1.Press the guard button. 2.Press the call button 3.After receiving by the guard, the call from lobby is accepted. 4.If the line is busy, the guard is having a call with others. 5.If the visitor presses [#] button, the call will be canceled. Self password authentication (For administrator) 1.Press [#] and [*] 2.Enter Password (Default : 1234) 3.Press [#], and then the door will be opened. Self password authentication (For Tenant) 1.Press [#] 2.Input unit number as 4 digits. 3.Enter the password that is registered from the household monitor. 4.Press [#] for completing the password.

12 EZON Components SHT-552XS FUNCTIONSPECIFICATION COMMUNICATIONRS-485(BUS) Wiring DistanceUTP CAT 5 : UPTO 500M ONE-TOUCH DIALSupport(max.18 dials) SELF-TESTSupport AWAY MODESupport COMMUNICATION CHECKSupport MMC SETUP INPUT HOUSEHOLD ID TABLE INPUT LOBBY ID TABLE INPUT NUMBER OF GUARDPHONE INPUT OUTSIDE GUARDPHONE CALL HOUSEHOLD CALL GUARDPHONE CALL LOBBYPHONE CALL SITUATION ALARM FIRE DETECT GAS DETECT BURGLAR DETECT EMERGENCY DETECT Public Unit Guardian Office Phone - UTP CAT 5 x 2EA (port) - Printer serial port included

13 EZON Components Public Unit

14 SHT-552XS/EN Setting – example Public Unit ○ How to register Building No, Main Control Unit, Households, and Lobby Phone 601 (06)602 (12) 501 (05)502 (11) 401 (04)402 (10) 301 (03)302 (09) 201 (02)202 (08) 101 (01)102 (07) LobbyGuard Office In-House Unit Lobby Phone Guard Office Phone Main Control Unit ItemsDescription Building No. 0101 Main Control Unit 01 In-House Unit (Household) 0101 ~ 0602 Lobby Phone 01 Lobby Entrance Password 1234 / 5678 Guard Office 01