1 Smart heat for comfort and safety Our capabilities for the commercial construction industry

2 Tyco Thermal Controls Applications in the commercial construction industry Systems that meet the application’s requirements Why Tyco’s systems?

3 Smart heat for comfort and safety: Our promise, our philosophy Demands for safety & comfort increased significantly Powerfull systems needed to meet investor’s demand Easy-to-use systems need to reduce projects time for engineers and installers Tyco Thermal Controls Complete systems for all applications in heat-tracing

4 A variety of brands under one roof

5 A variety of heat tracing applications Frost Protection & Comfort heating for –Commercial & Residential buildings –New construction & Renovation projects –Industrial process plants

6 The right system for every frost protection application Snow melting of ramps, footsteps... Frost protection for gutters and downpipes Frost protection for pipes

7 The right system for every comfort application Electrical floorheatingHot water temperature maintenance

8 Tyco Thermal Controls Applications in the commercial construction industry –Frost protection and comfort Systems that meet the application’s requirements Why Tyco’s systems?

9 Raychem frost protection for pipes Energy-efficient solution –Smart control unit will monitor the temperature and only activate the self-regulating cable when and where necessary. Safe –Cables can be overlapped without any risk of overheating RAYSTAT-ECO-10 control unit RayClic- connections FS-A/B-2X heating cable The smart control unit calculates the optimum heat requirements as a function of the ambient or pipe temperature

10 Raychem frost protection for gutters and downpipes Energy-effcicient –self-regulating heating cable automatically increases its heat output in icy water and decreases its output in dry air. –Smart control unit EMDR-10 only switches the cable on when necessary: after detection of both low temperature and humidity EMDR-10 control unit RayClic- connections GM-2X heating cable The smart control only switches the heating cable on when necessary: after detection of both low temperature and humidity

11 Raychem snow melting for ramps, steps, footpaths and stairways Safe –Reduces the potential for delays, lost business and vehicle damage. Reliable –T2 cables are ruggedly constructed to resist tough installation conditions in the concrete slabs. –Cables can be cut-to-length for maximum design flexibility VIA-DU-20 control unit EM2-XR heating cable The heating cable has unrivalled resistance to potential damage during installation Combined moisture and temperature sensor

12 Raychem hot water temperature maintenance Easy to design and install –Meters of pipe = meters of cable you need to guarantee hot water at all levels. –Enables a single pipe system, no need for return pipe work, valves or pumps, nor for complex design and balancing work. Reliable and maintenance-free HWAT-ECO control unit RayClic- connections HWAT-L/M/R Heating cable The meters of pipe correspond to the meters of cable needed

13 Raychem electrical floorheating Provides gentle heat for interior floors from concrete, tiles, marble or wood. The system completes the existing heating installation and increases the overall comfort feeling Ideal for renovation T2DigiTemp thermostat T2Reflecta Insulation plates T2Red Heating cable

14 Tyco Thermal Controls Applications in the commercial construction industry –Frost protection and comfort Systems that meet the application’s requirements –Complete systems; designed for the application Why Tyco’s systems?

15 The heart of our solutions is often the self-regulating cable Adjusts power output to compensate for temperature changes Flexible and safe –The cables can be safely overlapped without overheating Easy to use –Parallel cables can be cut or spliced to length on site. Delivers the right amount of heat exactly where and when it is needed

16 It’s not only the cable Range of control systems that optimise the solutions Specifically designed for the application Easy to set-up and operate Energy-efficient Control units complete the heat-tracing systems - providing exactly the required heat output at any given time and place.

17 Ergonomic and performant control units Easy set-up and operation –Easy-to-access for fast wiring –Intuitive, menu-driven operation –Pre-installed programmes Versatile and easy to select –A small selection covering many applications Designed for easy set-up and performant operation. T2DigiTemp Calculates when the floor heating is to be switched on to obtain the right temperature at the set time

18 A complete Raychem system can result in energy savings up to 80% The self-regulating cable with a smart control unit allows for dynamic management of the heating cable’s power output in function of various parameters such as ambient temperature and moisture. RAYSTAT- ECO-10 controls the frost protection system based on the ambient temperature

19 Easy-to-use installation components The Rayclic connection system cuts installation time by 80% The T2Red cable can be simply fixed into the grooves of the insulated T2Reflecta plates. The thin floor heating mat T2QuickNet comes with a self- adhesive layer for fast installation

20 Safe during installation and operation Tested to highest standards in Europe, certified by most important European approval agencies Completely safe installation: cables cannot overheat Service life of 20 year Tripple warranty for floorheating cables –PVC free –12 year product warranty –Low electric and negligible magnetic fields during operation

21 Excellent Technical support & Proximity Complete support at several levels –Advice on design and installation –Website www.tycothermal.com product selection wizards downloadable technical literature Frequently Asked Questions –Training support Large stock & fast fulfillment –Shipping of standard products in Europe within 2 days –Available from a professional wholesaler near you.

22 A proven track record Over the past 20 years, more than 120 000km of cable installed HM Treasury London 1,5 km frost protection system Royal Opera House London Greater energy-efficiency of hot water maintenance system

23 Tyco Thermal Controls Applications in the commercial construction industry –Frost protection and comfort Systems that meet the application’s requirements –Complete systems; designed for the application Why Tyco’s systems? –Smart heat for comfort and safety Easy-to-use system components Energy-efficient and reliable Excellent service Thank you for your attention Your Name yname@tycothermal.com