Presentation is loading. Please wait.

Presentation is loading. Please wait.

QPS Signal Analysis Case studies from MPP and QPS 04.09.2008 Bob Flora.

Similar presentations


Presentation on theme: "QPS Signal Analysis Case studies from MPP and QPS 04.09.2008 Bob Flora."— Presentation transcript:

1 QPS Signal Analysis Case studies from MPP and QPS 04.09.2008 Bob Flora

2 How do we Detect Quenches? Pressure Sensors Microphones Temperature Sensors Second Sound Fiber Optic Co-wound Cable Interferometer Bragg Diffraction Grating Backscatter Broadband Pulse Monochrome Pulse Sequence Electrical (Ohmic) Relative Balance Two Equal Elements (Los Vegas) Many Assorted Elements Absolute Current Measurement Differentiation dI/dt Inductive Model L(I) Voltage Measurement Missed Quenches must be pushed to Zero! False Quenches must be minimized.

3 Balance Detector (Analog) Two Equal Elements Main Dipoles B1 is balanced against B2 Main Quadrupoles half of one aperture is balanced against the other half U_QSO = -(U1+U2)

4 Dump Voltage +1V Diode Drop -1.2 Volts Entrance Voltage Exit Voltage Quench Signal (∑) x10 Heaters & Dump Fire! Diode Switches ON at -6 Volts

5 50˚K 433˚K 1.8˚K 77˚K 98˚K 147˚K 245˚K 18KW Peak Power

6 Quench Signal Test Ramp

7 Quench During Ramp Down

8

9

10 Hot Gas Quench

11 Imbalance During Quench Quench During Ramp Up

12

13

14

15

16

17 Tug of War

18 Vacillating Quench Signal

19

20 Typical Quench Behavior

21

22

23

24 Primary Quench Secondary Quenches

25

26 Symmetric Quench

27 Symmetric Quench Detail

28 Eddy Current Imbalance

29 Unquench Quench

30 Common Mode Error Switch Opens 30 Hz

31 First Beam Quench! Heater Quench Almost Collapses

32 Balance Detector (Digital) Two (almost) Equal Elements Individually Powered Magnets U_QSO = U1+U2

33

34

35 Quench While Ramping Up

36 Dipole Quench But Why Did the Heaters Fire???

37 Balance Error

38

39

40

41 Balance Detector (Distributed Digital) String against Reference Magnets Main Magnet Circuit Superconducting Bus

42 Balance Error

43 Balance Trip

44 Absolute Detector (Digital) Voltage and Current are Measured 600 Amp Circuits

45 QUENCH UQUQ U I R L R U L I+ R U dt d ( ) I+ R U U Q = U + L dt d ( ) I+ R U = U + L ( ) I+ R U Direct Quench Detection with Shunt Direct Quench Detection with Shunt SHUNT

46 Digianalog dI/dt Algorithm I (Hall Probe) I I dI/dt - - + + x 100

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69 Superconducting Link Quenches

70

71

72

73 Main Circuit Energy Extraction

74

75

76

77

78

79

80

81

82

83 600 Amp Energy Extraction

84

85

86

87

88 Quench Heater Discharge

89

90

91 Current Leads

92

93


Download ppt "QPS Signal Analysis Case studies from MPP and QPS 04.09.2008 Bob Flora."

Similar presentations


Ads by Google