Presentation is loading. Please wait.

Presentation is loading. Please wait.

FIT – Monash University High-Level Data Link Control

Similar presentations


Presentation on theme: "FIT – Monash University High-Level Data Link Control"— Presentation transcript:

1 FIT – Monash University High-Level Data Link Control
Topic 7 High-Level Data Link Control (HDLC) Reference: Chapter 7 – Stallings 7E, 6E

2 Introduction Widely used, and is the basis for many other important data link control protocols To satisfy a variety of applications HDLC defines: 3 types of stations 2 link configurations 3 data transfer modes of operations

3 Stations Primary station Secondary station Combined station
Responsible for controlling the operation of the link Frames issued by these stations are called commands Secondary station Operates under the control of the primary station Frames issued by a secondary are called responses Combined station Combines the features of primary and secondary. Issues both commands and responses

4 Link Configurations Unbalanced configuration Balanced configuration
Consists of one primary and one or more secondary stations and supports both full-duplex and half-duplex transmission Balanced configuration Consists of two combined stations and supports both full-duplex and half-duplex transmission

5 Transfer Modes Normal response mode (NRM)
Used with an unbalanced configuration The primary may initiate data transfer to a secondary, but a secondary may only transmit data in response to a command from the primary Asynchronous balanced mode (ABM) Used with balanced configuration Either combined station may initiate transmission without receiving permission from the other station Most widely used mode of the 3 Asynchronous response mode (ARM) Used with unbalanced configuration The secondary may initiate transmission without explicit permission of the primary

6 HDLC Frame Structure HDLC uses synchronous transmission
All transmissions are in the form of frames, and a single format suffices for all types of data and control exchanges The flag, address (identifies the secondary station that transmitted or is to receive), and control fields that precede the information field are known as a header The FCS and flag fields following the data field are referred to as a trailer

7 HDLC Frame Structure

8 HDLC Frame Structure The flag fields delimit the frame at both ends with the unique pattern A single flag may be used as the closing flag for one frame and the opening flag for the next The protocol allows the presence of arbitrary bit patterns, (in jpeg, mpeg, wav files), a property known as data transparency As a result, there is no guarantee that the flag pattern will not appear somewhere inside the frame, thus destroying synchronisation

9 Bit Stuffing Receiver hunts for flag sequence to synchronize on frame
Bit stuffing used to avoid confusion with data containing 0 inserted after every sequence of five 1s If receiver detects five 1s it checks next bit If 0, it is deleted If 1 and seventh bit is 0, accept as flag If sixth and seventh bits 1, sender is indicating abort

10 Pitfalls of Bit Stuffing
When a flag is used as both an ending and starting flag, a 1-bit error merges two frames into one Conversely, a 1-bit error inside the frame could split it in two

11 HDLC Frame Structure

12 Types of Frames Information frames Supervisory frames
(I-frames) carry data to be transmitted for the user Additionally, flow and error control data, using ARQ mechanisms, are piggybacked on an information frame Supervisory frames S-frames provide the ARQ mechanism when piggybacking is not used Unnumbered frames U-frames provide supplemental link control functions

13 HDLC Frame – Control Field
The first one or two bits of the control field serve to identify the frame type The remaining bit positions are organised into subfields as indicated in the next slide

14 HDLC Frame Structure

15 HDLC Frame – Control Field
All of the control field formats contain the poll/final (P/F) bit In command frames, it is referred to as P bit and is set to 1 to solicit (poll) a response frame from the peer HDLC entity In response frames, it is referred to as the F bit and is set to 1 to indicate the response frame transmitted as a result of a soliciting command

16 HDLC Frame – Control Field
Basic control field for S- and I-frames uses 3-bit sequence numbers An extended control field can be used for S- and I-frames that employs 7-bit sequence numbers U-frames always contain an 8-bit control field

17 HDLC Frame Structure Information field is present only in I-frames and some U-frames The length of the information field is variable up to some system-defined maximum The frame check sequence (FCS) field is used for detecting errors using a code calculated from the remaining bits of the frame, exclusive of flags

18 Operation HDLC operation consists of exchange of I-frames, S- frames, and U-frames between 2 stations The operation of HDLC involves three phases Initialisation Data transfer Disconnect

19 Operation - Initialization
One side or the other initialise the data link so that frames may be exchanged in an orderly fashion During this phase, the options that are to be used are agreed upon Initialisation is requested by issuing one of 6 set mode commands

20 Operation - Initialization
The set mode command Signals the other side that initialisation is requested Specifies which of the 3 modes (NRM, ABM, ARM) is requested Specifies whether 3- or 7-bit sequence number s are to be used If the other side accepts this request, the HDLC module on that end transmits an unnumbered acknowledgment (UA) frame back to the initiating side If the request is rejected, a disconnected mode (DM) frame is sent

21 Operation – Data Transfer
After initialisation, the two sides exchange user data and control information to exercise flow and error control To exchange data and control information, a logical connection is established. Both sides may begin to send user data in I-frames, starting with sequence number 0. Placed the sequence number in N(S) field.

22 Operation – Data Transfer
Flow Control S-frames are used for flow control The receive ready (RR) frame acknowledges the last I-frame received by indicating the next I-frame expected N(R) indicates which number I-frame it expects to receive next The RR frame is used when there is no reverse user data traffic (I-frames) to carry an acknowledgment Receive not ready (RNR) acknowledges an I-frame, as with RR, but also asks the peer entity to suspend transmission of I-frames

23 Operation – Data Transfer
Error control REJ initiates the go-back-N ARQ- it indicates that the last I-frame received has been rejected and that retransmission of all I-frames beginning with number N(R) is required SREJ is used to request retransmission of just a single frame

24 Operation – Disconnect
Finally, one of the 2 sides signals the termination of the operation Either HDLC module can initiate a disconnect, either on its own initiative if there is some sort of fault, or at a request of a higher layer user HDLC issues a disconnect by sending a disconnect (DISC) frame The remote entity must accept the disconnect by replying with a UA and informing its layer 3 user about the disconnection

25 Examples of Operation

26 Examples of Operation


Download ppt "FIT – Monash University High-Level Data Link Control"

Similar presentations


Ads by Google