1 Turku PET Centre EXTRACTING ARTERIAL BLOOD CURVE FROM PET IMAGE - UPDATE Abdominal aorta in [ 15 O]H 2 O studies

2 1.3.2016Turku PET Centre Improved method Method contains –95% thresholding –Recovery coefficient User has to specify the range of planes Initial value for diameter is not needed

3 1.3.2016Turku PET Centre Thresholding For each frame –Find the pixel with maximum activity (inside the vessel) –Include all pixels where activity value is greater than 0.95*maximum activity (=thresholding) –Calculate mean => thresholded TAC

4 1.3.2016Turku PET Centre Recovery coefficient Estimate diameter of the vessel Calculate the recovery coefficient

5 1.3.2016Turku PET Centre Resulting input TAC RC * thresholded TAC

6 1.3.2016Turku PET Centre Diameter estimates (mm)

7 1.3.2016Turku PET Centre Result TACs

8 1.3.2016Turku PET Centre AUC correlations

9 1.3.2016Turku PET Centre Future plans Article dealing with input extraction Validation of diameter estimates with help of ultrasound results Comparisons with ICA