Electronic Timing Official Training Clinic. Agenda Introductions Role of ET Official Certification Process Equipment Setup Operating the Console Paperwork.

Similar presentations


Presentation on theme: "Electronic Timing Official Training Clinic. Agenda Introductions Role of ET Official Certification Process Equipment Setup Operating the Console Paperwork."— Presentation transcript:

1 Electronic Timing Official Training Clinic

2 Agenda Introductions Role of ET Official Certification Process Equipment Setup Operating the Console Paperwork – Determining the official time Worked Examples Questions

3 OSI Officiating Philosophy Fair and equitable conditions of competition are maintained and uniformity in the sport is promoted so that no swimmer has an unfair advantage over another

4 What does that mean? Success of every meet depends on the official’s integrity, knowledge, concern and regard for the competitive interest of the swimmer One set of rules applies to all swimmers Swimmers get the benefit of the doubt Demonstrate impartiality and professionalism on deck

5 Professionalism on Deck Wear standard uniform Typically white polo over blue shorts Long pants/skirts for championship finals Sometimes khaki instead of blue No team logos or advertising Wear credentials and name tag Be in position on time. Do not vacate position until replacement in place

6 The ET Official Why? No swimmer shall be required to re-swim a race due to equipment failure which results in unrecorded or inaccurate time or place. (USA Swimming Rule 102.16.4D) What? Part of a larger officiating crew Operate electronic timing equipment Determine official time Instruct timers in proper timing procedures

7 Certification Process Register through Oregon Swimming as non-athlete member of USA Swimming Must pass a background check through USA Swimming Must attend USA Swimming online Athlete Protection Training Attend ET Clinic before working on deck Begin volunteering at meets After minimum 20 hours of training & 5 sessions, obtain 2 positive recommendations from certified ET’s Forward training record and recommendations to ET chair Await confirmation to take online test. Take and pass on-line open-book test

8 Minimum Training Requirements Attend ET Clinic At least 2 of the first 6 hours must be with a designated ET Trainer 10 observed hours on timing console 10 observed hours on time verification Complete a Deck Tour with Referee Work a minimum of 5 ET sessions Work two sessions at sanctioned 12 & under meet Work at least one session at a non-home meet Work one session with the Hy-Tek operator Be familiar with both Colorado and Daktronics and their setup Successfully complete a heat and lane malfunction calculation (by hand) Receive two consecutive positive recommendations from two different trainers

9 Proper Timing Procedures Instructions for Head Timers & Timers Timer operates one watch and one button. No timer can operate both watches or both buttons Start watch at strobe flash rather than sound if possible Raise hand if you fail to start watch – head timer should have a backup Stop watch and button when touch is seen Record times legibly on supplied event sheet to 100ths of a second Head timer will collect event sheets Ring bell on long events

10 Set Up Timing Equipment Be familiar with Colorado and Daktronics systems Know how to set up and operate the equipment Allow time before the meet to set up and diagnose problems Home crew will often set up equipment, but you still need to check it over Ensure starting unit connected Ensure buttons and pads in place and connected using harness or deck plates Perform test start and then reset for first race

11 Typical ET Setup Scoreboard Timing Console Results Computer Starting Console Pads Buttons

12 Operate Timing Equipment Ensure ET console set for correct event and heat ET Console should start timing when starting unit sounds If ET console fails to start, start it manually & write “manual start” on ET heat sheet Check for No Shows/Lanes turned on/off Mark No Shows on ET heat sheet with NS and strike through Write race number on ET heat sheet When ET unit on deck avoid making console beep just prior to the start Check for intermediate pad touches. Add/Delete touches as required Finish arm lane(s) if necessary Store-Print; Reset; Advance to Next Heat or Next Event FOCUS ON DRIVING THE CONSOLE WHEN TASKED TO DO SO ET TIP: Delay manual start for 10 sec so all know there was a timing problem

13 Determining the Official Time Automatic / Semi-Automatic / Manual Primary / Secondary / Tertiary times What is the official time?

14 Types of Timing Systems Rule 102.24.2 Automatic Automatic start. Finish on touch pads Semi-Automatic Automatic start. Finish on buttons Manual Watches

15 Timing System Designation Rule 102.24.3 Primary The most accurate system available Could be automatic, semi-automatic, or manual Normally automatic PADS Secondary Backup to primary system. Typically BUTTONS Tertiary At least one watch should be used as a back up for a automatic or semi-automatic system

16 Determination of Official Time Timing resolution in 100ths, not 1000ths of seconds. Thousandths are dropped with no rounding (102.24.1B) The time from the correctly operating primary system is the official time (102.24.4) Automatic: Pad time Semi-Automatic or Manual Middle time of 3 buttons/watches Average of 2 buttons/watches Time of single button/watch (not a good idea)

17 Primary Timing System Malfunction 102.24.4C A malfunction may have occurred if: The difference between the time obtained by the primary system and the back-up system(s) is approximately 0.30 second or greater, or The place judge(s) reports a different order of finish, or It is reported the swimmer missed the touchpad or had a soft touch.

18 Lane Malfunction 102.24.4D Effective May 1, 2016, back-up times do not need to be adjusted for timing differences. Use button time reported by timing console. Note that Colorado automatically deducts 0.15 seconds but Daktronics does not. Both are acceptable. Use watch time without adjustment.

19 Time Verification (Pad, Button & Watches) 5/1/16 At least one button confirms pad time Y Use pad time Watches confirm one button time and faster than pad Y Collect order of finish and coach’s time. Compare with pad/watch/button times. Use best judgment. Watches confirm each other and faster than pad Y Use watch average N At least one watch confirms pad time Y N N N Buttons confirm each other and faster than pad Y N Use button average ET TIP: Calculate the adjusted button average, when the pad is not confirmed & 2 buttons agree, before watch times arrive to speed the process! Use button

20 Adjustment for Lane Malfunction 102.24.4D prior to May 1, 2016 Back-up times need to be adjusted for timing differences. The adjustment for timing system difference is determined by calculating the consistent average difference between the valid primary and valid backup systems used at that meet. A primary and backup time is considered “valid” if they are within approximately 0.30 seconds of each other. Note that High School and Masters rules still require adjustment of back-up times.

21 Adjustment for Lane Malfunction 102.24.4E prior to May 1, 2016 Back-up times shall be adjusted by calculating the average difference between valid primary and valid back-up times of the other lanes in that heat, or if necessary, using times from heats immediately preceding and/or following the heat. This shall be done by adding, or subtracting when appropriate, that average difference to the valid back-up time of the lane where the malfunction occurred.

22 Automatic/Semi-Automatic/Manual Buttons & Watches are affected differently by human reaction time Start Human Delay Button Pad Watch Finish Colorado Timing Console automatically deducts 0.15 Human Delay

23 Adjustment for Lane Malfunction Button times and watch times need to be adjusted by “timing system difference” Check that there are 3 valid lanes for comparison Calculate average difference between pad and valid button (or watch) times in that heat

24 Finding consistent average If less than 3 valid lanes, look at previous and next heats of same stroke Progressively look at previous and next heats until a good average is found (3 or more valid lanes) Consider the opposite gender event of same age, distance, and stroke Only consider a different event if you have exhausted all valid heats in the current event.

25 Time Verification (Pad, Button & Watches) Pre May 2016 At least one button confirms pad time Y Use pad time Watches confirm one button time and faster than pad Y Collect order of finish and coach’s time. Compare with pad/watch/button times. Use best judgment. Watches confirm each other and faster than pad Y Calculate pad-watch average difference and use adjusted watch average N At least one watch confirms pad time Y N N N Buttons confirm each other and faster than pad Y N Calculate pad-button average difference and adjust the button average ET TIP: Calculate the adjusted button average, when the pad is not confirmed & 2 buttons agree, before watch times arrive to speed the process! Calculate pad-button average difference and adjust the one button

26 Adjustment for Lane Malfunction 102.24.4D Effective May 1, 2016, back-up times no longer need to be adjusted for timing differences. No need to look at the current, previous and next heats to provide a consistent average. Use button time reported by timing console. Use watch time without adjustment. Note that High School and Masters rules still require adjustment of back-up times.

27 Time Verification (3 Watches) Two watches the sameUse watch time Collect order of finish and coach’s time. Use best judgment. If no valid time, use the middle watch time. One time not validated is not ideal, benefit of doubt to swimmer N Only two valid watch times available (both within 0.30 seconds) Take the average of the two watches N Middle watch within 0.30 seconds of the other two N Use middle watch time One of the 3 watches more than ±0.30 seconds from either of the other two valid watches (both within 0.30 seconds) Discard the outlier and take the average of the two watches N valid watch or button; def. having another time within approximately 0.30 seconds of that time Y Y Y Y

28 Time Verification For further confirmation, optionally check the Order Of Finish (OOF) to see that the adjusted time fits the place order Further investigation is needed when: Buttons slower than pad confirm each other Times validated “just barely” by approximately 0.30 seconds

29 Order of Finish Starter will provide the OOF, listing the lanes in order that they arrived at the finish Example: OOF of 4-3-2-5-6-1 would be: OOF LanePlace 1 st Lane 4 16 2 nd Lane 3 23 3 rd Lane 2 shown as: 32 4 th Lane 5 41 5 th Lane 6 54 6 th Lane 1 65 Do not confuse OOF with finish place Other notation suggests unsure or too close to call for lanes 2,5,6: 43 - - - 1 43 256 1 4 3 256 1

30 Order of Finish OOF can be used to determine that a timing malfunction may have occurred OOF is an aid when no clear validation between pads, buttons, and watches is clear OOF also useful in validating times when 3 watches are used as the primary timing system OOF is valuable, but is the least reliable piece of information available to the ET Official Reliability is subjective

31 Common Timing Consoles Colorado Data Systems 6 Colorado Data Systems 5 Daktronics Omni-sport 2000 or 6000

32 Colorado 6 Automatically calculates the lane timing adjustment on the buttons. Button times already have built-in subtraction of 0.15 seconds Colorado 6 correctly looks at individual button-pad differences and includes lanes where one button is valid. Observe the +/- sign for the Colorado 6 “backup delta” adjustment negative (-) adjust adds time to the average button positive (+) adjust subtracts time to the average button

33 Colorado 6 Need to turn off the built in averaging system after May 1, 2016 The built in averaging system will still be used for High School and Masters meets

34 Colorado 6 (continued) 1. Use the softkeys on the right to select “Setups” 2. Use Up/Down softkeys to select “Timing” 3. Use Up/Down softkeys to select “Automatic Backup Time Adjustment” 4. Use Off softkey to turn off

35 Colorado 5 A commonly used flow for the older Colorado-5 is to use the built-in 0.15 adjustment as the “consistent average”. Although widely used in the past, this is no longer recommended, however is considered “acceptable” by OSI for non-championship meets. It is recommended that lane timing adjustments are performed (using Hy-Tek Meet Manager) on all lanes with primary system malfunctions.

36 Colorado 5 It is acceptable to use the built-in 0.15 adjustment applied to the button times after May 1, 2016.

37 Daktronics Does not do any button adjustment Beware that button averages on the Daktronics printout may be rounded up instead of truncated (depending upon version) When using optional PC interface, keeps a running race log with all touches and buttons that can be retrieved.

38 Daktronics Prior to May 1, 2016 and for High School and Masters meets Lane timing adjustments are performed (using Hy-Tek Meet Manager) on all lanes with primary system malfunctions

39 Hy-Tek Meet Manager Software on the Results Computer Set up meets Manage entries Seed races with swimmers Prints heat sheets & psych sheets Captures the times from the timing console Assimilates the results Scores the meet Prints awards labels

40 Hy-Tek Meet Manager Run Menu highlights timing anomalies in color

41 Configuring Meet manager In Meet Manager 6 the timing adjustment method can be specified in the meet set up

42 Configuring Meet manager In Meet Manager 4 or 5 the timing adjustment method can be set in the run screen preferences for backup times.

43 Hy-Tek “Calc menu” Calculates the pad-button lane timing adjustment and applies it to the average button time Use for calculating lane timing adjustments with Daktronics and Colorado 5 when needed Print the Calc worksheet to attach to time printouts

44 Hy-Tek Lane Timing Print Shows how the adjustment was arrived Example: Used lanes 3,4,6,7,8,10 to find the difference and applied the average difference to Lane 5 where the button was faster than the pad Would use this time if at least one watch validated (within approximately 0.30) Lane 5, Button 1.

45 Hy-Tek Calc Known Problems May not use all the valid pad/buttons Example: Lane 9 Primary and Button 2 could have been used in determining adjustment average because both were ‘valid’ May or may not affect the final adjustment average

46 Hy-Tek Calc Known Problems May incorrectly use invalid buttons if the average of the buttons is valid Example: One obviously invalid button (Ln8 Btn 2), was used in the calculation of the adjustment average Lane 5’s official time was dropped by 0.05 seconds because of one invalid button!

47 Hy-Tek MM Issue Hy-Tek incorrectly uses the button average and not the individual button times The lane should be included in the calculation if one button is valid, and only valid buttons should be used in the calculation. Solve this by removing the invalid button times and re-run the calc again

48 Heat Malfunction Adjustment If automatic system subject to early or late start (manual start is pushed), need to adjust ALL times For each valid lane (pad validated by button), calculate average WATCH - PAD difference Discard any watch outliers that are more than 0.30 from the norm Adjust all automatic and semi-automatic times by average WATCH - PAD difference

49 Documenting Official Time Obtain heat printout from console Check correct race#, event#, heat# Check that times available for all lanes which had swimmers Document any no-shows Document any DQ’s (see next slide) Calculate official time. (may need to wait for watch times) Clearly identify official time with check mark and strike out invalid times Attach timing adjustment sheet if used Initial paperwork Pass paperwork to Hy-Tek when appropriate Hy-Tek may send paperwork back if discrepancies

50 Other Official Times Rule 102.24.1A Official times may be achieved in: Any heat A swim off A lead-off leg in a relay A split time recorded from the official start to the completion on an initial distance with a legal finish within a longer event, provided the swimmer completes the event or the lead-off portion of the relay in compliance with applicable rules A time trial or a record attempt

51 Other Official Times A lead off leg in a relay Relay lead off leg times are automatically entered into the SWIMS database and are available as official times. If there is reason to believe that the pad time for the lead off time is inaccurate it can be removed from the meet database in the splits window of the run screen. Splits can only be edited in the cumulative splits mode. If it is known that a relay lead off swimmer is attempting to achieve a time 3 watches to record the split time are recommended so that in the event of a pad failure the swimmer has a valid primary timing system.

52 Other Official Times A split time recorded from the official start to the completion on an initial distance Can be achieved in any swim. If it is known that a swimmer is attempting to achieve an initial distance time 3 watches to record the split time are recommended so that in the event of a pad failure the swimmer has a valid primary timing system. Initial distance split times are not automatically recorded in SWIMS as an official time. OSI SWIMS manager must be informed. Document the details. Meet director can note all details with the meet results submission Email to the OSI SWIMS manager

53 Handling DQ Slips Check DQ slip for correctness with ET heat sheet Swimmer/Team Name Event/Heat/Lane Signed by referee If any discrepancies, send DQ back to referee Strike out times for swimmer Denote DQ alongside strikeout Write the lane(s) and name(s) of those DQed Attach DQ slip to back of printout, facing backwards – enables easy review later if required Console operator can advise of potential DQs so that paperwork can be held back until DQ’s arrive Often DQ’s arrive after paperwork passed on and has to be recalled ET TIP: DQ notations written in red are not overlooked !

54 Working with Hy-Tek Before the meet starts: Meet info is downloaded from Hy-Tek to console Most current heat sheet is printed for ET Hy-Tek gets meet results from console Check for DQs before passing on paperwork, although DQs may arrive later anyway Often best to pass verified event paperwork over in one batch to Hy-Tek operator Keep console turned on until Hy-Tek operator confirms that ALL meet info has been transferred ET TIP: ET heat sheet printed 1 event per page is useful

55 Working with the Referee, Starter, Timers, & Coaches Console operator needs to get console ready for next heat in a timely manner Request order of finish from starter if doubt over time validation (wait for starter to acknowledge you) Obtain watch times from lane timers Obtain watch times from coaches If timing issues are consistently from one lane then observe timers in that lane and talk to them if necessary Get referee to sign off on any unusual timing circumstances

56 Problem Solving Often something will go wrong and the problem needs to be fixed quickly Pad not working Know where a backup pad is to swap Button not working Know where backup buttons are to swap Printer not working Extra paper? ink/toner? printer? Console not working Do you have three stop watches per lane? ET TIP: To swap pads & buttons, ask Ref to pause the meet between heats, even if unused lane

57 Worked Examples

58 Summary Role of ET Official Certification Process Equipment Setup Operating the Console Paperwork – Determining the official time Worked Examples Questions

59 Questions ?