Presentation is loading. Please wait.

Presentation is loading. Please wait.

DODO RESULTS: Campaign Averages & BAe-146 Nephelometer Findings Claire McConnell Ellie Highwood Acknowledgements: Paola Formenti, Met Office, FAAM.

Similar presentations


Presentation on theme: "DODO RESULTS: Campaign Averages & BAe-146 Nephelometer Findings Claire McConnell Ellie Highwood Acknowledgements: Paola Formenti, Met Office, FAAM."— Presentation transcript:

1 DODO RESULTS: Campaign Averages & BAe-146 Nephelometer Findings Claire McConnell Ellie Highwood Acknowledgements: Paola Formenti, Met Office, FAAM

2 DODO Flights DODO 1 Feb 2006 DODO 2 Aug 2006

3 DODO Average Properties DODO1DODO2 ObservationsMieObservationsMie ω 0 550 0.98 ± 0.02 0.98 0.96 ± 0.03 0.96 Refractive index 1.53 - 0.001i1.53 - 0.0029i g 550 0.69 σ ext 550 /m -1 3.13E-03 ± 1.88E-03 1.15E-04 ± 1.02E-04 k ext 550/ m 2 g -1 0.881.15

4 Under-sampling in the Nephelometer Coarse particles are lost in the inlet of the nephelometer During SHADE (2000) AODs derived from scattering on the C-130 required multiplication of 1.5 to agree with AERONET AODs, implying an inlet cut-off between 1.3 and 1.9μm radius. (Haywood et al., 2003) Experiments on BAe-146 nephelometer: 1.The intercomparison between the BAe-146 and the NASA DC-8 during DODO2 allowed a comparison between the nephelometers 2.Size distributions measured during DODO & Mie code allow an analysis of the under-sampling 3.Under-sampling can be estimated through comparisons with ground-based sites These processes allow an estimation of the factor of sampling missed and of the cut-off radius on the BAe-146 nephelometer

5 Intercomparison with NASA DC-8 BAe-146 and DC-8 show same spatial variability in scattering –correlation coefficients vary between 0.93-0.96 Difference in absolute scattering measured –average ratio of DC-8/BAe-146 uncorrected scattering = 2.1 Hypothesis: The BAe-146 nephelometer is underestimating the total DODO dust scattering at 550nm by a factor of 2-3, and is only measuring submicron (diameter) scattering Uncorrected nephelometer scattering for 3 straight level runs – bold=BAe-146, light=DC-8

6 Correlation plots of 146 vs DC-8 uncorrected scattering for 3 wavelengths for 3 different SLRs performed wingtip- wingtip. Each panel has a different horiz/vertical scales, but has same range on both x & y axes. Black = 550nm with 146 data scaled by a factor of 2.1

7 Comparison with AERONET AODs for DODO2 calculated by integrating BAe-146 profile data AERONET AODs for the same times are a factor of 3.2 larger than those from the nephelometer profiles (but factor varies between 2 and 4.5) Results consistent with the DC-8 intercomparison FlightProfileUncorrectedAERONET τ 550 Correction factor τ 440, Level 2.0 B236P100.1120.2 B237P80.2320.5 B238P10.134.50.6 B238P90.153.30.5 B242P10.04100.4 B242P11/P120.1040.4 Average4.3 AODs from BAe-146 profiles and from AERONET station at Dakar

8 Estimation of Nephelometer Cut-off Radius The size distribution was measured by the PCASP and SEM sizing during DODO ‘Cut-off test’ – average size distribution successively ‘cut-off’ at decreasing radii to mimic the loss of the coarse mode Each size distribution run through Mie code to obtain scattering/absorption properties ‘Cut-off Factor’ (C) calculated – factor required to match the ‘cut- off’ scattering/absorption/extinction with that of the full size distribution Size distributions available for use in the cut-off test

9 Results from Cut-off Tests Submicron sampling (r<0.5μm) results in a scaling factor of 3 for the nephelometer ω 0 is considerably lower if the full size distribution is considered

10 Conclusions on Cut-off Radius on BAe-146 Nephelometer Submicron sampling on the 146 neph would result in a cut-off factor of 3 The AERONET-derived scaling factor suggests a cut-off of 0.5μm DC-8 intercomparison-derived scaling factor suggests a cut off of 0.8-1μm Suggested cut-off, around r=0.5μm, appears to be smaller than experienced for dust during SHADE 2000 Caveats Mie work assumes spherical particles Cut-off factors may change with different size distributions (e.g. more/less coarse mode present)

11 Future Work Observations Results from radiometers Results from Edwards & Slingo radiation code Chemistry –Iron Content, for deposition –Refractive indices, for comparison with derived values Specific case studies, comparison to remote sensing Modelling DODO – dust modelling, comparisons to observations, deposition estimates


Download ppt "DODO RESULTS: Campaign Averages & BAe-146 Nephelometer Findings Claire McConnell Ellie Highwood Acknowledgements: Paola Formenti, Met Office, FAAM."

Similar presentations


Ads by Google