Presentation is loading. Please wait.

Presentation is loading. Please wait.

Integrating a Continuous Water Quality Monitoring Network into Texas’ Surface Water Quality Monitoring Program Jill D. Csekitz, Aquatic Scientist Texas.

Similar presentations


Presentation on theme: "Integrating a Continuous Water Quality Monitoring Network into Texas’ Surface Water Quality Monitoring Program Jill D. Csekitz, Aquatic Scientist Texas."— Presentation transcript:

1 Integrating a Continuous Water Quality Monitoring Network into Texas’ Surface Water Quality Monitoring Program Jill D. Csekitz, Aquatic Scientist Texas Commission on Environmental Quality Austin Texas Austin Texas

2 Disclaimer The use of firm, trade, or brand names is for identification purposes only and does not constitute endorsement by the TCEQ. The use of firm, trade, or brand names is for identification purposes only and does not constitute endorsement by the TCEQ.

3 What is Continuous Monitoring? A device that makes repeated measurements over time A device that makes repeated measurements over time Deployed over an extended length of time Deployed over an extended length of time Samples at high frequencies to identify trends or events Samples at high frequencies to identify trends or events Data is usually available in real-time over the internet Data is usually available in real-time over the internet

4 Total Area: 268, 581 sq. miles Water Area: 6, 784 sq. miles France: 211, 209 sq. miles 1754 Active Routine Surface Water Quality Monitoring Stations 23 Continuous Water Quality Monitoring Stations © 1998-2005 Texas and The Territories, Inc. All Rights Reserved.

5

6 The TCEQ Continuous Water Quality Initiative Upstream Dairies -Erath County -Cow Population: 50,000 -North Bosque River impaired -phosphorus -excessive algae Downstream drinking water -Lake Waco -Taste and odor -City of Waco -People Population: 117,464 TCEQ adds continuous monitoring in Bosque watershed to track improvements in water quality

7 TCEQ’s Existing Program 23 stations in TX 23 stations in TX 2 stations deployed in 2001 2 stations deployed in 2001 4.4 stations each year since 2001 4.4 stations each year since 2001 Partnerships with local, state and federal entities Partnerships with local, state and federal entities Parameters monitored Parameters monitored Physical parameters Physical parameters Nutrients – nitrate, ammonia, and total reactive phosphorus Nutrients – nitrate, ammonia, and total reactive phosphorus Depth profiling in reservoirs Depth profiling in reservoirs

8 Deployed Stations

9 Equipment

10 Costs of Establishing and Maintaining a Monitoring Site

11 How Does TCEQ Mitigate Cost of Network? Form partnerships with local, state, and federal entities Form partnerships with local, state, and federal entities 12 participating entities 12 participating entities Share resource burden Share resource burden Use existing infrastructure (USGS) Use existing infrastructure (USGS) Host data Host data

12 Data Record Produced Wow… 525, 600 data points! What do we do with them? Grab vs. Continuous: Why Compare? -Different monitoring objectives -Based on different scale of sampling

13 Uses of Continuous Monitoring Yield high resolution data Yield high resolution data Public display of data Public display of data Identify seasonal trends and daily variation Identify seasonal trends and daily variation Assess point and non-point impacts Assess point and non-point impacts Assess improvement after BMPs are in place Assess improvement after BMPs are in place

14 General Quality Assurance Continuous monitoring network - specific QAPP Continuous monitoring network - specific QAPP SOPs written for site deployment, equipment operation and maintenance, and data validation SOPs written for site deployment, equipment operation and maintenance, and data validation Technical Systems Audits Technical Systems Audits Pre-processed automatic validation Pre-processed automatic validation Suspicious values Suspicious values Instrument limits Instrument limits Database automatically “grades” multiprobe data according to calibration verification results Database automatically “grades” multiprobe data according to calibration verification results Data Validator manually validates all data Data Validator manually validates all data Only data that passes validation is publicly displayed Only data that passes validation is publicly displayed

15 How Do We Get the Most Out of Our Continuous Data? Variety of Data Users Variety of Data Users Identify data quality – let users decide what they need Identify data quality – let users decide what they need

16 Multiprobe Calibration Verification

17 Aqualab QC Daily calibration of Physicals and TRP Daily calibration of Physicals and TRP On-board laboratory control standards (ammonia, nitrate, and TRP) On-board laboratory control standards (ammonia, nitrate, and TRP) Dynamic calibration of ammonia and nitrate (every measurement) Dynamic calibration of ammonia and nitrate (every measurement) On-board standards are made and certified by a contract lab On-board standards are made and certified by a contract lab Output of all calibration data Output of all calibration data

18 Aqualab Conductivity QC

19 Aqualab NO 3 and NH 3 Diagnostics Shows sensor response to on-board standards

20 Aqualab Automated QC Actual LCS Concentrations -155 ppb - 40 ppb Instrument blanks

21 TCEQ’s Uses of Continuous Monitoring Data Water diversion from drinking water supplies Water diversion from drinking water supplies Characterizing golden algae blooms Characterizing golden algae blooms Targeting field investigations Targeting field investigations BMP effectiveness BMP effectiveness Effectiveness of salt cedar eradication Effectiveness of salt cedar eradication Trend analysis of specific conductance, pH and DO Trend analysis of specific conductance, pH and DO 305b reporting 305b reporting

22 Available Data Parameters Parameters DO* DO* pH* pH* Temp* Temp* Conductivity* Conductivity* Turbidity Turbidity Chlorophyll Chlorophyll Nitrate Nitrate Ammonia Ammonia Total Reactive Phosphorus Total Reactive Phosphorus Flow Flow Not all parameters available at every station Not all parameters available at every station Most Stations: only field parameters are measured Most Stations: only field parameters are measured

23 Data on the Web http://www.tceq.state.tx.us/compliance/monitoring/water/quality/data/wqm/swqm_realtime_swf.html Or… Search “continuous water data” on TCEQ home Page: www.tceq.state.tx.us

24

25 Questions? Jill Csekitzjcsekitz@tceq.state.tx.us 512.239.3136 Texas Commission on Environmental Quality MC – 165 PO Box 13087 Austin, TX 78711 – 3087 www.tceq.state.tx.us


Download ppt "Integrating a Continuous Water Quality Monitoring Network into Texas’ Surface Water Quality Monitoring Program Jill D. Csekitz, Aquatic Scientist Texas."

Similar presentations


Ads by Google