Presentation is loading. Please wait.

Presentation is loading. Please wait.

IBL cooling branch layout and commisioning 6 febryuary 2014 Jan Godlewski, Bart Verlaat, Tomasz Blaszczyk, Eric Richards, Lukasz Zwalinski, Sven Vogt,

Similar presentations


Presentation on theme: "IBL cooling branch layout and commisioning 6 febryuary 2014 Jan Godlewski, Bart Verlaat, Tomasz Blaszczyk, Eric Richards, Lukasz Zwalinski, Sven Vogt,"— Presentation transcript:

1 IBL cooling branch layout and commisioning 6 febryuary 2014 Jan Godlewski, Bart Verlaat, Tomasz Blaszczyk, Eric Richards, Lukasz Zwalinski, Sven Vogt, Claudio Bortolin 1

2 34 DCS: TTa24 - TTn24 EH122 TS122 22 MVa24 - MVn24 04 06 FL018 ⅜” AV017 20 36 BD016 PT116 / PT316 TT116 / TT316 26 32 28 30 Tracking detectors Tile calorie meter LAR calorie meter MV018 MV036 14 IBL staves (a-g),(7 flow pairs) (7x A-›C flow / 7x C-›A flow) Detector boundary Junction box @ Muon Sector 5 (Accessible) Dry volume LAR Cryo area HX036 ½” ¾”x 5 / 16 ” ⅜” Dummy load (testing only) BD020 PT120 / PT320 TT120 / TT320 DCS: TTa28 – TTn28 DCS: TTa30 – TTn30 BD036 PT136 / PT336 TT136 / TT336 MV035 EH117 TT117 TS117 26 28 30 32 HX012 FL017 MV017 Manifold box (S5) 08 USA-15 USX-15 DN40 vacuum Vacuum system (LAR Cryo area) DN40 ⅜” ¼” ½” BV,28-01-2014 Transfer tubes (~92m) CO2: 10x1mm inside 21.3x2.11mm outside 16 A200 A100 B400 B300 C042 D012 Flow dir Stave # Flow dir a12C-A b13A-C c14C-A d1A-C e2C-A f3A-C g4C-A h5A-C i6C-A j7A-C k8C-A l9A-C m10C-A n11A-C TTz20 (DCS) 24 TTz36 (DCS)

3 Seen from C-side 3 Flow orientation A to C C to A A to C C to A Loop # Stave # Flow dir a12C-A b13A-C c14C-A d1A-C e2C-A f3A-C g4C-A h5A-C i6C-A j7A-C k8C-A l9A-C m10C-A n11A-C

4 Seen from A-side 4 Stave 1 Stave 2 3 14 6 11 12 Flex line A1…A7 7 6 5 4 3 2 1 Flex line #Stave #Flow A112Vapor 13Liquid A214Vapor 1Liquid A32Vapor 3Liquid A44Vapor 5Liquid A56Vapor 7Liquid A68Vapor 9Liquid A710Vapor 11Liquid Splitter box color Tube color Splitter box Designed by Lapp and lpnhe

5 Seen from c-side 5 Stave 1 Stave 2 3 14 6 11 12 Flex line #Stave #Flow C112Liquid 1313Vapor C214Liquid 1Vapor C32Liquid 3Vapor C44Liquid 5Vapor C56Liquid 7Vapor C68Liquid 9Vapor C710Liquid 11Vapor Splitter box color Tube color Flex line C1…C7 1 2 3 4 5 6 7 Splitter box Designed by Lapp and lpnhe

6 Flex line arrangement in manifold 6 To A-sideTo C-side A1, 12 in, 13 outA2, 14 in, 1 outA3, 2 in, 3 outA4, 4 in, 5 outA5, 6 in, 7 outA6, 8 in, 9 outA7, 10 in, 11 outC1, 13 in, 12 outC2, 1 in, 14 outC3, 3 in, 2 outC4, 5 in, 4 outC5, 7 in 6 outC6, 9 in, 8 outC7, 11 in, 10 out In= vapor in from stave Out=Liquid out to stave Manifold seen from C-side

7 Flex line commissioning Connection sequence: –Route lines –Connect rotatable connector to manifold box (both vacuum and CO2) –Leave IBL lines disconnected from detector but in vicinity. –Test vacuum system with lines attached. –Pressure test flex lines –Connect CO2 from junction box –Perform flow tests with warm CO2 (~15’C) using inter connects – Empty lines and connect to IBL –Fill with CO2 and ready for IBL cooling test 7

8 8

9 Back-up slides 9

10 Vacuum transfer line (From S5 to IDEP) 10 Super insulation 7x 1.6mmOD / 1.0mmID concentric inlet tube 7x 4mmOD / 3mmID outlet tube 7x 16mmOD vacuum hose We have to grasp the bundle from under- neath the muons and bend it in place 50mm PVC tube mock-up Ca. 11m long

11 Routing in IDEP Side A.

12 Routing in IDEP Side C.

13 IDEP Side A 13 A B B A IDEP cover fit check Mock-up tubes, may not be covered with cables or so.

14 IDEP Side C 14 B A B A IDEP cover fit check Mock-up tubes, may not be covered with cables or so.

15 Sector 5 area (Junction box and manifold) 15 Tomasz Blaszczyk To cooling plant in USA Junction box Manifold box Flex lines to IBL The junction box contains a dummy heater for commissioning and has valves to close off the IBL. Also accessible filters are present.

16 Junction box 16

17 17 Manifold box How to connect and disconnect a cooling line

18 flex line 18 11meterManifold box side IBL side Sven Vogt

19 flex line connection, IBL side 19

20 20 flex line connection, Manifold side


Download ppt "IBL cooling branch layout and commisioning 6 febryuary 2014 Jan Godlewski, Bart Verlaat, Tomasz Blaszczyk, Eric Richards, Lukasz Zwalinski, Sven Vogt,"

Similar presentations


Ads by Google