Presentation is loading. Please wait.

Presentation is loading. Please wait.

A Semianalytical p/z Technique Abnormally Pressured Gas Reservoirs

Similar presentations


Presentation on theme: "A Semianalytical p/z Technique Abnormally Pressured Gas Reservoirs"— Presentation transcript:

1 A Semianalytical p/z Technique Abnormally Pressured Gas Reservoirs
SPE 71514 A Semianalytical p/z Technique for the Analysis of Abnormally Pressured Gas Reservoirs Ronald Gunawan Gan, VICO Indonesia and T. A. Blasingame, Texas A&M University

2 Objective To present a new technique that can be used to :
Calculate gas-in-place for an abnor- mally pressured gas reservoir using only average reservoir pressure and cumulative production data. Calculate pore volume compressibi- lity as a function of reservoir pressure.

3 Presentation Outline Introduction Overview of Existing Methods
New Method Field Examples Conclusions

4 p/z schematic for a normally-pressured
Introduction p/z schematic for a normally-pressured volumetric gas reservoir p/z Gp G

5 p/z schematic for an abnormally-pressured
Introduction p/z schematic for an abnormally-pressured gas reservoir p/z Gp Gapp G

6 Introduction Reasons for the non-linear p/z behavior:
Rock and water compressibility effects — "rock collapse theory" (Hawkins, 1969) Shale water influx (Bourgoyne, 1989)

7 Existing Methods Methods based on presumed knowledge of
system compressibility: Hammerlindl (Constant Compressibility), 1971 Ramagost & Farshad (Constant Comp.), 1981 Yale et al. (Variable Compressibility), 1993

8 Methods based on presumed knowledge of
system compressibility (continued) Fetkovich, Reese, and Whitson - Derived General Material Balance Eq. - Define cumulative effective compressibility, - ce represents the cumulative change in hydrocarbon PV caused by compressi- bility effects (and water influx).

9 Methods which do not require a prior
knowledge of system compressibility Roach - very sensitive to initial pressure. - method sometimes doesn’t exhibit a negative intercept (which is not possible). Bernard - using Least Squares approach. - very sensitive to data scatter. Ambastha : Type Curve Approach - non-uniqueness problems.

10 New Method Satisfies both "rock collapse" and
"shale water influx" theories Develops 2 new plotting functions: 1. 2. Requires production data only (p and Gp)

11 New Method Uses general material balance equation
(proposed by Fetkovich, et al.) Rearranging, we obtain

12 New Method Calculate the ce(pi-p) function for
each p/z versus Gp trend ce(pi-p) = ??? Gp p/z G Gapp ce(pi-p) = ???

13 New Method For early time data (1st straight line) :
For late time data (2nd straight line) : where: A is the inflection point

14 New Method Plot of log ce(pi-p) versus (p/z)/(pi/zi): log ce(pi-p)
inflection point G/Gapp=0.6 G/Gapp=0.7 G/Gapp=0.8

15 New Method Plot of log ce(pi-p) versus (p/z)/(pi/zi) : log ce(pi-p)
inflection point

16 New Method (p/z)/(pi/zi) Gp/G 1 Infl. Point: GpA/G, (p/z)A /( pi /zi )
1 Gp/G

17 New Method (p/z)/(pi/zi) Gp/G 1 G/Gapp=0.6 Inflection point h
1 Gp/G

18 New Method 1 G/Gapp=0.8 Inflection point h (p/z)/(pi/zi) 1 Gp/G

19 New Method Dynamic Type Curve Matching.
Automatic Matching using SOLVER m(Excel function for non-linear regression).

20 New Method Data required for analysis: Fluid property data
Initial Reservoir p and T p and Gp data

21 Easy to use - especially for analysis
New Method Computer program: Visual Basic Application in MS Excel Only requires MS Excel Easy to use - especially for analysis

22 Data Analysis Sheet

23 Example 1: G is too low

24 Example 1: G is too high

25 Example 1: Correct G

26 Example 2: Long transition period

27 Example 3: Early time data

28 Example 4: Synthetic Dry Gas Case

29 Example 4: Backcalculated cf
Procedure to calculate cf vs. p from production data: 1. Get from type curve matching 2. Use the following equation to calculate : 3. Calculate cf (p):

30 Example 4: Backcalculated cf

31 Conclusions We have developed a straightforward
approach for analyzing p/z versus Gp behavior for abnormally pressured gas reservoirs — the approach considers that two straight-lines must be ob- served on the p/z plot. The proposed method determines gas-in-place without using system compressibility data. Only p, Gp, and fluid property data are required.

32 Conclusions (continued)
Our approach of using ce(pi-p) versus (p/z)/(pi /zi) and (p/z)/(pi /zi) versus Gp/G as dynamic type curve matching func- tions has been shown to work extreme- ly well. Using our new method, it is possible to calculate rock compressibility as a func- tion of pressure from p and Gp data

33 Conclusions (continued)
The "dynamic type curve matching technique" used for calculating gas-in-place from production data is more representative (and more stable) than the non-linear optimization method provided by SOLVER.

34 A Semianalytical p/z Technique Abnormally Pressured Gas Reservoirs
SPE 71514 A Semianalytical p/z Technique for the Analysis of Abnormally Pressured Gas Reservoirs Ronald Gunawan Gan, VICO Indonesia and T. A. Blasingame, Texas A&M University


Download ppt "A Semianalytical p/z Technique Abnormally Pressured Gas Reservoirs"

Similar presentations


Ads by Google