Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF.

Similar presentations


Presentation on theme: "Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF."— Presentation transcript:

1 Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF

2 Leak tests 29.01.2004 Tests are based on using: AFS 1400 – Bidirectional Mass Flow Meter Characteristics of AFS 1400: - dynamic range: 0.03 – 400 sccm -Fast response time: 150 ms -Calibrated & Temperature compensated (for air & Nitrogen) -Digital output signal ( RS-232) (http://www.sensirion.com)

3 Leak tests 29.01.2004 Flow meter opened F1: 1.023e-6 l/s F2: -1.621e-7 l/s F3: -1.391e-7 l/s F4: 1.057e-7 l/s

4 Leak tests 29.01.2004 Flow meter shorted F1: 1.014e-6 l/s F2: -1.441e-7 l/s F3: -1.244e-7 l/s F4: 8.529e-8 l/s

5 Leak tests 29.01.2004 Flow meter Flow meter Temperatures

6 Leak tests 29.01.2004 Connection in series “Brooks” mass flow controller

7 Leak tests 29.01.2004 Leak test of Module 5012 (5m prototype) (N) Flow meter F1 Bubbler (8 mbar) closed Module 1 2 Steps: 0. Tap 2 is always closed. 1.Tap 1 is opened, gas is pumping the module in. 2.Tap 1 is closed, module is under 8 mbar overpressure, F1 is measuring. Leakage criterion: Leakage flow must be of the order (or less) of 1e-6 l/s.

8 Leak tests 29.01.2004

9 Flow meter F1 Module F2 Flow meter straw outer Gas Gas volumes (straw/outer) separation

10 Leak tests 29.01.2004 Gas volumes (straw/outer) separation Flow meter F1 Module F2 Flow meter straw outer Gas

11 Leak tests 29.01.2004 How to proceed ? -Better tubes & taps -Atmospheric pressure & temperature monitoring -Flow controller -Nitrogen/Argon