Presentation is loading. Please wait.

Presentation is loading. Please wait.

AMS TIM & General Meeting ACC Testbeam Performance & KSC Cosmic Data Ch Chung, A. Goerres, Th. Kirn I. Phys. Institute B, JSC Gilruth Center Houston, 24th.

Similar presentations


Presentation on theme: "AMS TIM & General Meeting ACC Testbeam Performance & KSC Cosmic Data Ch Chung, A. Goerres, Th. Kirn I. Phys. Institute B, JSC Gilruth Center Houston, 24th."— Presentation transcript:

1 AMS TIM & General Meeting ACC Testbeam Performance & KSC Cosmic Data Ch Chung, A. Goerres, Th. Kirn I. Phys. Institute B, JSC Gilruth Center Houston, 24th January 2011

2 2 2010 August Testbeam → ACC Inefficiency Studies Beam Rotation stand

3 3 2010 August Testbeam Configuration 4 positions for ACC-test (1) panel (8mm thickness), exchanged PMT(3) slit region (2x4mm thickness), shared PMT (2) panel (8mm thickness), original PMT(4) slit region (2x4mm thickness), separate PMT 180 GeV proton-beam Ø beamspot: ~ 3 cm

4 4 Event Selection Requirements: - Trigger from Upper TOF - Single reconstructed TRD-Track - TRD-Track matching beam config. - matching TOF-hit positions

5 5 TOF-hit matching TRD track TRD track – center of TOF panel good event

6 6 Event Selection Requirements: - Trigger from Upper TOF - Single reconstructed TRD-Track - TRD-Track matching beam config. - matching TOF-hit positions

7 7 Requirements: 7.661.060 - Trigger from Upper TOF 5.310.522 - Single reconstructed TRD-Track 2.994.861 - TRD-Track matching beam config. 705.926 - matching TOF-hit positions 528.643 Event Selection

8 8 Inefficiency (only TRD-Track) ACC inefficiency: I < 6.00 · 10 -6 (@ 95% CL) requirement: Idesign < 10-4 Missed Events Panel (8 mm thickness) (P1, P2): 0 out of259,245 → I < 1.16·10 -5 Slit region (2x4mm thickness), shared PMT (P3): 0 out of125,010 → I < 2.40·10 -5 Slit region (2x4mm thickness), different PMT (P4): 1 out of144,268 → I < 4.00·10 -5 ~6cm P4P1P2P3 8mm panel region: ~73% slit region: ~27%

9 9 Event Selection using Tracker Requirements: - Trigger from Upper TOF - Single reconstructed TRD-Track - TRD-Track matching beam config. - matching TOF-hit positions - Tracker information Tracker information (3 Tracker-layers below TRD)

10 10 Requirements: 7661060 - Trigger from Upper TOF 5310522 - Single reconstructed TRD-Track 2994861 - TRD-Track matching beam config. 705926 - matching TOF-hit positions 528643 - min. 2 matching TrCluster-hits on first 3 layers below TRD 415966 - linear fit / check for chi² 324826 - track predicts ACC-hit 322884 Event Selection 322,884 events after all cuts

11 11 TrCluster: - distance from all Cluster-hits to extrapol. TRD-track - x & y coordinate of nearest hit is within TRD-track- uncertainty (~1cm) Matching Tracker-hits

12 12 Matching Tracker-hits TrCluster: distance from all Cluster-hits (incl. multiplicity) to extrapol. TRD-track x & y coordinate of nearest hit is within TRD-track- uncertainty (~1cm) multiplicity

13 13 Fit Quality of Tracker track min. 2 matching hits on 3 Tracker-layers below TRD fit linear Track through points, not including bending in y-direction check for chi²

14 14 Dimensions panel width:22 cm beamspot Ø: 3 cm Slit region (nut & spring) width of slit region between panel: 0.6 cm Inefficiency Missed Events and Inefficiency Panel (8 mm thickness): 1 out of304,022 → I < 1.90·10 -5 Slit region (2x4mm thickness), shared PMT: 0 out of 9,450 → I < 3.17·10 -4 Slit region (2x4 mm thickness), different PMT: 0 out of 9,412 → I < 3.18·10 -4

15 15 ~97% ~3% of total scintillator-area ACC Inefficiency: I < 1.89 · 10 -5 (@ 95% CL) requirement: Idesign < 10-4 Inefficiencies Panel (8 mm thickness): I < 1.90·10 -5 Slit region (2x4mm thickness), shared PMT: I < 3.17·10 -4 Slit region (2x4mm thickness), different PMT: I < 3.18·10 -4 single inefficiencies weighted corresponding to area Dimensions panel width:22 cm beamspot Ø: 3 cm Slit region (nut & spring) width of slit region between panel: 0.6 cm Inefficiency

16 16 ADC-Spectra for 180 GeV p-Beam Typical ADC-spectra as input for MC-studies

17 17 TDC-Spectra for 180 GeV p-Beam Typical ADC-spectra as input for MC-studies

18 18 2010 KSC Cosmic Data Period → ACC Stability

19 19 - TRD-track for prediction of ACC-hit - only the center of panel is taken into account 2010 KSC Cosmic Data Period Wake Ram

20 20 2010 KSC Cosmic Data Period ACC Signal MOP / 10,000 events Zoom..

21 21 2010 KSC Cosmic Data Period ACC Stability ACC Signal MOP / 10,000 events In the same configuration period, all 16 PMTs are stable less than 2% level

22 22 2010 KSC Cosmic Data Period ACC Stability Wake +ZRAM +Z Wake -ZRAM -Z