1 Replacement for COROS LS-C ?

2 Starting situation Spare parts are not available
Invest „los Engineering" ? Alternative „new control system„ Confine teeth with automation Complete new project engineering, there no conversion of project engineering data (e.g. after WinCC) available Different control concepts Performance losses possible

3 The Solution ! new control system migration on WINCC COROS LS-C ME

4 Replacement for COROS LS-C ?
new control system migration on WINCC (cemat V5) COROS LS-C ME

5 new control system Exchange and new project engineering of the control station hardware Exchange and new project engineering of the PLC New project engineering of all communications and Subcontrols Coupling of existing inputs/output periphery Restarting operation of the overall system

6 Replacement for COROS LS-C ?
New control system Migration to WINCC (Siemens) COROS LS-C ME

7 Migration on WINCC SIMATIC-suppostion expansion CPU 948
Engineering-Station control Station expansion SIMATIC S5 155U R I/O A D Graphic Color OS - AG COROS Master Server SIMATIC S7-400 SIMATIC-suppostion CPU 948 CP143 oder CP1430 30 kWorte = 60 kByte Profibus DP

8 Migration on WINCC Exchange and new project engineering of the control station hardware No costs on the automation side (PLC) for - New project engineering - New start-up - Wiring - Input/output periphery - Re-education of your service personnel Resembles control philosophy Minimum plant stop

9 Which costs a migration on WINCC ?
OS Client RT License per Client WINCC ca € OS Server RT License per Server WINCC, CP ca € Engineering Station License, 1x WINCC, CP1613 ca €

10 Which costs a migration on WINCC ?
Hardware Network components depending upon Personal computer depending upon desire Server computer depending upon desire Engineering Engineering expenditure after system size and version, approx men months Adjustment Subcontrols

11 Replacement for COROS LS-C ?
new control system migration on WINCC COROS LS-C ME

12 Example of a configuration COROS LS-C

13 Example of a configuration COROS LS-C ME

14 Advantages of LS-C ME (1)
Standard computer applicable Use of Windows 2000/XP Performance increase Use of current standard printers Integration into existing networks - Employment of modern safeguard methods - Use of net drive assemblies - Use of network printers

15 Advantages of LS-C ME (2)
Increase of the reliability possible, by - RAID CONTROLLER - high-available servers Simple data protection Over network possible Disaster Recovery, e.g. with Norton Ghost Remote maintenance, (e.g. pcAnywhere) Operator station at the same time also for other applications usable Multi-monitoring possible (not LS-C ME)

16 Transferred for LS-C ME
LS-C ME is compatible, i.e. no changes - in project engineering or - in the host system necessarily With necessary an on-line setting did not even transfer from LS-C V5,72 is Conversion of the disks (5¼ and/or 3½) IRMX format) takes place via third The old system remains unchanged, i.e. back stairs are at any time possible Projecting bar remains complete

17 Conditions for transferred
Starting point LS-C V evtl. Upgrade is possible on new platform Hardware-Plattform change CP-Cxx to CP-CLAN change OS-Cxx to Windows 2000 / XP computer LAN connection make Software Installation , is provided the appropriate Scriptfiles converts project engineering if necessary on 5.72 (V7.1)

18 Restrictions of LS-C ME
Light pen is not supported Touch screen does not implement at present Dissolution of diagram reduced, i.e. small differences in picture geometry possible Process control keyboards must be attached over converters CP printers must (to be allowed!) as network printers to be installed

19 Planned extensions for LS-C ME
exportfunction (in to csv-format) for Measure archive Annunciation archive PDO-file archive OPC server for the access to the measured values of the host (input/output of ranges) Migration path to WinCC

20 Software architecture LS-C
Simatic Simicro S MMC VDU-Kommunikation Hostkommunikation Bildaktuali-sierung Meßwert-bearbeitung Meldungs-bearbeitung Prozeß-Datenabbild CP-Cx Darstellung CP-Kommunikation Dialoge + Masken Meßwert-Archiv Meldungs-Archiv PDO Daten-haltung Editoren OS-Cx OT-Cx

21 Software architecture LS-C ME
Simatic Simicro S MMC Hostkommunikation Bildaktuali-sierung Meßwert-bearbeitung Meldungs-bearbeitung Prozeß-Daten-abbild CP-CLAN Darstellung Dialoge + Masken Meßwert-Archiv Meldungs-Archiv PDO Daten-haltung Editoren OS-C ME Host-Kommunikation TCP/IP

22 Migration path to WinCC
Simatic Simicro S MMC Hostkommunikation CP-CLAN Host-Kommunikation TCP/IP Prozeß-Datenabbild B+B-System z.B. WinCC OPC-Server

23 What costs transferred to LS-C ME?
Licencens OS-C ME Masterlizenz € ,- OS-C ME Slavelizenz € ,- Hardware CP-C ME € ,- netware component € ,- Industrial PC computer P4 € ,- 18“ Flat screen € ,- Engineering Engineering expenditure after system size and version, approx men days

24 When you can transfer ? Delivery release V 7.x April 2003
all function are avaliable and testet

25 Which use does COROS LS-C ME have ?
Solution of the spare part problems by standard hardware 10 years supply and to support warranty Simple administration by operation system (WIN2000/XP) up-to-date

26 with further question ? SAPI Software GmbH D-67346 SPEYER
Fon: +49 (0) Fax: +49 (0)