Presentation is loading. Please wait.

Presentation is loading. Please wait.

A users viewpoint: absorption spectroscopy at a synchrotron Frithjof Nolting.

Similar presentations


Presentation on theme: "A users viewpoint: absorption spectroscopy at a synchrotron Frithjof Nolting."— Presentation transcript:

1 A users viewpoint: absorption spectroscopy at a synchrotron Frithjof Nolting

2 Bottom layer “pinned” Hard layer or Exchange coupling Top layer “free” can be switched MRAM Hard disk head Magnetic data storage and recording Low resistance high resistance GMR Element

3 FM AFM Interface - Different models for AFM/FM coupling exist. - Different assumptions on AFM structure lead to complete different results. - Spin arrangement at the interface is important High Spatial Resolution Elemental Sensitivity Ferromagnetic Contrast Antiferromagnetic Contrast Surface/Interface Sensitivity How? X-ray absorption spectroscopy (XAS) with spatial resolution Photoemission Electron Microscope (PEEM)

4 Photoemission Electron Microscope I (nA) h Energy E F ~ ~ h (x-ray) core level valence band 2p 3/2 2p 1/2 Magnetic lenses e-e- 16° analyzer 20 kV X-rays Sensitive to: elemental composition chemistry structural parameters electronic structure magnetic properties ELMITEC GmbH

5 Magnetic microscopy S E XMCD (X-ray Magnetic Circular Dichroism) XMLD (X-ray Magnetic Linear Dichroism) LaFeO 3 Co 5 µm J. Stöhr et al. Science 1993A. Scholl et al. Science 2000 F. Nolting et al. Nature 2000

6 Exchange biased Co/NiO multilayer EPU beamline 4 at ALS.... 3 nm Co 50 nm NiO 1.5 nm Ru 3 nm Co 30° Magnetic field Left and right circularly polarized light XMCD Hysteresis of Co and NiO XMCD spectra – switching polarization Pinned Moments ? H. Ohldag, A. Scholl, F. Nolting, E. Arenholz, S. Maat, A.T. Young, M. Carey, and J. Stöhr, Phys. Rev. Lett. 91(1), 017203/1-4 (2003).

7 Ratio of A/B Antoine Barbier et al User experiment at SLS, July 2004

8 SIM Beamline Layout Undulator T. Schmidt 2 Elliptical undulators Pure permanent magnet 95eV < h < 2000eV >10 19 photons/s/mrad 2 /mm 2 /400mA 100 % circular polarization [125 - 900 eV] reduced on higher harmonics Hor. & vert. linear polar. Optics U. Flechsig Plane grating monochromator E/  E > 8000 <5% 2 nd order light Switch helicity Focus 30x100  m 2 Endstation C. Quitmann & F. Nolting SLS endstation: –PEEM & LEEM  x~25 - 50nmspatial  E~150meV energy –Sample Prep chamber –User endstation Front end Prepchamber ID 1 ID 2 MonochromatorChopper Refocusing optics Microscope User endstation

9 TEY Reference signal Sample signal Magnet Sample = Norm Reference Moving gap and monochromator, stop, measure (1s – 1minute), moving … How do we measure

10 Change polarization and repeat Take difference of spectra Absorption spectrum requires frequent moving of gap and shift must not effect other beamlines transparent!

11 switching by moving phase switching by moving the gap tuneddetuned move up 56 mm move 2 mm move 0 mm detuned tuned circ plus circ minus chopper 120 s 1s - 8 s 100 Hz Modes for switching the polarization switching by using a chopper

12 Alignment of IDs - Horizontal 1. Horizontal overlap at Frontend ID1 ID2 Asymmetric bump 2D Frontend scan Closed bump using chicane magnets 2. Horizontal overlap at focus of experiment ID2 Intensity Horizontal position

13 Alignment of IDs - Vertical 3. Vertical (energy) overlap at focus of experiment ID1 ID2 not yet finished ! Photon energy Intensity ID2 Absorption spectrum schematic 778.3 eV source mono Exit slit

14 Beam variation - Noise horizontal movementintensity variation XAS normalization reduces it by a factor of 10-100 PEEM no normalization daysno problem hoursno problem sec - minutesbad mili secondsok vertical movementenergy variation no normalization! daysno problem hours bad secondsbad mili secondsok 10 μm about 2% 10 μm about 10 meV

15 Energy shift Energy shift of 10 meV Identical spectra 1 %

16 Orbit feedback Fast orbit feedback slow orbit feedback beam position in ID (Bergoz) X-ray position in beamline Shift and gap Orbit correctors?

17 Orbit feedback – effect on measurement Normalized signal, circular plus Difference circular plus and minus Increased noise!!!

18 Slow Orbit feedback Circular plus Circular minus beam position in ID (Bergoz) X-ray position in beamline Shift and gap Orbit correctors?

19 Slow Orbit feedback Not transparent ! 10 μm

20 Summary We can do great measurements at SLS  Transparent IDs are essential! Very difficult to make an EPU transparent. Have to rely on Orbit feedback  For the measurement “no” difference between slow and no Orbit feedback  Critical time scale second – hour (10 Hz – 0.0001 Hz) Intensity variation 0.1% 0.5 μm energy variation 1meV 1 μm  Slow Orbit feedback is not sufficient Fast Orbit feedback is great


Download ppt "A users viewpoint: absorption spectroscopy at a synchrotron Frithjof Nolting."

Similar presentations


Ads by Google