Presentation is loading. Please wait.

Presentation is loading. Please wait.

Technische Universität München Status report on SADC feature extraction.

Similar presentations


Presentation on theme: "Technische Universität München Status report on SADC feature extraction."— Presentation transcript:

1 Technische Universität München Status report on SADC feature extraction

2 Technische Universität München Outline Feature extraction fitting pulses –General idea –Parameter sets –Implementation AC noise suppression Performance (comp. to std. alg.) –Energy spectrum for e - calibration – 0 mass spectrum Conclusion

3 Technische Universität München Feature extraction using functional parameterization Describe pulses by analytic function (Silicon, J. Friedrich) Fix function parameters (calibration) Fit/Calculation of time and amplitude

4 Technische Universität München Typical pulse and its description

5 Technische Universität München Result of fit (first parameter) Using three parameter sets for ECAL02 Parameter sets depend on shaper not on cell type!!

6 Technische Universität München Signals on two different channels Analytic calculation of function variables due to large amplitude error not desirable

7 Technische Universität München AC coupling

8 Technische Universität München AC Coupling suppression (ACS) AC coupling signals have amplitude independent length Remove all signals with a half-width 5 Problems for small signal introduce threshold to apply cut

9 Technische Universität München 40 GeV e - Beam – ECAL calibration (std: green, pf: red)

10 Technische Universität München 40 GeV e - Beam – ECAL calibration (std: green, pf: red)

11 Technische Universität München 40 GeV e - Beam – ECAL calibration (std: green, pf+acs: blue)

12 Technische Universität München M( 0 ) (PulseFit & AC suppresion) VS std. FE slightly improved energy resolution (~ 4%) slightly improved signal to bg ratio ~ (0.2%) reduced signal integral (~ 8%)

13 Technische Universität München Deeper analysis: Feature of shower reconstruction (instable against small changes ) M( 0 ) PulseFit VS std. FE increased signal integral (~ 4%) decreased energy resolution (~ 50%) decreased signal to bg ratio (~ 20%)

14 Technische Universität München Conclusion Alternative method for feature extraction available Electron beam performance (without calibration adaption) promising Reconstruction problems for 0 observed Improvement by adaption of shower reconstruction possible? Increased CPU usage (for physics runs 20% of total runtime) Fine tuning needed (dep. on shower reconstruction) For the moment std. reconstruction is the preferable option!!!

15 Technische Universität München Thank you.