Presentation is loading. Please wait.

Presentation is loading. Please wait.

Mass hierarchy using medium baseline detector Yoshitaro Takaesu KIAS/KNRC In collaboration with S.F. Ge, N. Okamura and K. Hagiwara arXiv: 1210.8141.

Similar presentations


Presentation on theme: "Mass hierarchy using medium baseline detector Yoshitaro Takaesu KIAS/KNRC In collaboration with S.F. Ge, N. Okamura and K. Hagiwara arXiv: 1210.8141."— Presentation transcript:

1 Mass hierarchy using medium baseline detector Yoshitaro Takaesu KIAS/KNRC In collaboration with S.F. Ge, N. Okamura and K. Hagiwara arXiv: 1210.8141

2 Introduction Reactor Experiments can determine the Neutrino Mass Hierarchy. The sensitivity is studied for determining the Mass Hierarchy is measured. ・ Can determine MH independently from CP phase and matter effects ・ free and well-studied source of neutrino Advantages of reactor neutrino experiment

3 How to distinguish Mass Hierarchy ? Mass Hierarchy difference Max: vanish:

4 MH difference in spectrum

5 analysis The theoretical prediction is fitted to the Data, assuming NH or IH. Fitting parameters are Penalty term

6 analysis We define Naively, the significance of this rejection is, but… NH IH Not appropreate for the MH determination c.f.) Qian et.al. arXiv: 1210.3651 Evslin et.al. arXiv: 1305.5150 NH is true: tends to be Positive. IH is true: tends to be Negative. IH is rejected NH is rejected NH is true case

7 IH is true Interpretation of When we perform many pseudo-experiments, the approximately follows a Normal distribution. 0 NH is true When we perform an experiment and get a, we reject the IH assumption with the confidence of ( 1 – p ).

8 Interpretation of Dashed: Solid: There are studies based on Bayesian approach. This is a frequentist approach to interpre t. Qian et.al. arXiv: 1210.3651 Evslin et.al. arXiv: 1305.5150

9 Sensitivity to the Mass hierarchy 16.5 GW 10 kton 5 yrs Current value NH

10 Effect of Energy Resolution 2 16.5 GW 10 kton 5 yrs Sensitivity is reduced by ~ 40 % Optimized L is shortened by ~ 5 km b = 0 % b = 1 % a = 2 % a = 3 %

11 Parameter measurement < 0.5 % accuracy can be measured accurately @ L ~ 50 km L = 50km 1%1% 1%1% 1%1% 1%1% After mass hierarchy determination

12 Multi-reactor interference L1 L2 E. Ciuffoli, J. Evslin, X. Zhang: 1302.0624 Y-F. Li, J. Cao, Y. Wang, L. Zhan: 1303.6733 Baseline difference should be small. ΔL = L1 – L2

13 Multi-reactor interference 1 Other reactor sites influence the sensitivity. All Reactors 16.5 GW 10 kton 5 yrs a = 3 %, b = 0.5 % YongGwang only

14 Multi-reactor interference 2 All Reactors Distributions of Each Reactors considered The direction to RENO50 strongly affects the sensitivity. 16.5 GW 10 kton 5 yrs a = 3 %, b = 0.5 %

15 Summary We have discussed the sensitivity of RENO50-like Experiment for MH determination. With 16.5 GW 10 kton, a < 3% (2%) b < 0.5 % (1%) of Energy Resolution is required for > 80% probability of > 2-sigma (3-sigma) determination within 5 years. Interference among reactor sites and reactor cores significantly affects the sensitivity.

16 Back Up Slides

17 Reactors in South Koreahttp://world- nuclear.org/info/Country- Profiles/Countries-O-S/South- Korea/#.UYzutiv24hx from World Neuclear Association http://world-nuclear.org/info/Country-Profiles/Countries-O-S/South-Korea/#.UYzutiv24hx

18

19 PMT Reactor neutrino experiment Reactor Detector Inside Detector Inverse Beta Decay (IBD)

20 Energy Distribution @ Detector near far

21 Fourier Analysis has sensitivity for small. Don’t need accurate knowledge of or flux.

22 Pull Factors of fitting parameters

23 Effects of to the sensitivity L = 30 km L = 50 km Baseline should be long enough

24 Effect of Energy Resolution a = 0 a = 6 % Evergy Resolution affects the sensitivity significantly. How good should be the energy resolution ?


Download ppt "Mass hierarchy using medium baseline detector Yoshitaro Takaesu KIAS/KNRC In collaboration with S.F. Ge, N. Okamura and K. Hagiwara arXiv: 1210.8141."

Similar presentations


Ads by Google