Presentation is loading. Please wait.

Presentation is loading. Please wait.

SFT2841 disconnected Prepare setting files Experts: L.GIGLI

Similar presentations


Presentation on theme: "SFT2841 disconnected Prepare setting files Experts: L.GIGLI"— Presentation transcript:

1 SFT2841 disconnected Prepare setting files Experts: L.GIGLI
Pedagogy: C.CAYLA Duration: mn

2 SFT 2841 expert UMI The UMI on the front panel of Sepam may be completed by an expert UMI comprising the SFT2841 PC software tool, which may be used for all Sepam functions parameter setting, local operation and customization. The expert UMI comes as a kit, the SFT 2841 kit, which includes: Sepam software CD CCA 783 cord Cable usb telemecanique

3 Sepam software CD Sepam software CD

4 Autorun After the CD is inserted, Autorun displays this screen.
Sepam software CD Overview of the software Parameter setting Autorun After the CD is inserted, Autorun displays this screen. You may choose: SFT2841 installation SFT2826 installation Presentation of the Sepam offer Sepam range application solutions documentation product implementation different specifications per application order form

5 Code entry SFT2841 may be installed in
Sepam software CD Généralités Parameter setting Code entry SFT2841 may be installed in demonstration version or full version Demonstration version no serial number requested connected mode disabled file saving disabled Full version enter the serial number on the label stuck on the back of the CD box format: XXXXXXX-XX

6 Sepam software CD Généralités Parameter setting Content SFT2841 v9 Readme.txt Lisezmoi.txt Install Demo SFT2826v0202 Disks Sepam_presentation Sepam v4.0_FR Sepam v4.0_E The Readme files give the required configuration for installation of the software The Demo directory contains the files used by the Sepams in Series 80 demo case

7 OVERVIEW OF THE SOFTWARE

8 Starting the application
Sepam software CD Overview of the software Parameter setting Starting the application Click on the icon Select the working language Choose the operating mode: connected point to point via the front panel via the network disconnected (according to Sepam) create a new file or edit an existing file Same access for SFT connected

9 Sepam software CD Overview of the software Parameter setting Screen organization Title bar: displays the Sepam file identification name Menu bar (contextual): provides access to all of the software functions Toolbar (contextual): Direct access to principal functions Work zone: contextual tab boxes available to the user Status bar: gives information on the active window

10 Toolbar Sepam parameter setting Matrix Function setting
Sepam software CD Overview of the software Parameter setting Toolbar Sepam parameter setting Matrix setup environment automation inputs / outputs Function setting disturbance recording mimic diagram Protection setting Logipam setting Guided navigation for logical sequencing of screens Equation editor

11 Guided navigation Linking of screens Hardware setup 1
Sepam software CD Overview of the software Parameter setting Guided navigation Linking of screens Series 20 Series 40 Series 80 Hardware setup 1 General characteristics 3 2 CT-VT sensors CT-VT circuit supervision 4 Particular characteristics 5 Control logic 6 Logic input/output assignment 7 Protection functions 8 Logipam 9 Logic equations 10 Matrix 11 Disturbance recording 12 Mimic-based UMI 13

12 Software help Series 20 & 40 Series 80
Sepam software CD Overview of the software Parameter setting Software help Series 20 & 40 Series 80 Opening of the Sepam operating manual The file opens up directly on the page that corresponds to the SFT2841 screen

13 Saving the file Saving by default in the Sepam directory
Sepam software CD Overview of the software Parameter setting Saving the file Saving by default in the Sepam directory Entry of the file name File extension series 20, rpg series 40 and 80, type of Sepam (e.g. M41)

14 Editing a report Enter the report identification information Print
Sepam software CD Overview of the software Parameter setting Editing a report Enter the report identification information Print

15 Editing a report Series 20 & 40 Text file
Sepam software CD Overview of the software Parameter setting Editing a report Sepam xxxx (21/03/2006) Properties Customer: Training Project: Series 20, 40 & 80 Switchboard: File Cubicle: Series 20 Print date: 24/04/06 Sepam hardware configuration Type of application: Substation (S20) Sepam Type: Sepam xxxx Sepam model: UD model (with fixed advanced UMI) MES (Input / output module): MES114 (10I + 4O module) MSA141 (1 analog output module): Absent DSM303 (Remote advanced UMI module): Absent Interface de communication: Absent Synchronization mode: Network Set up outputs Used Shunt coil Undervoltage coil Pulse mode O1 Yes X O2 Yes X O3 Yes X O4 Yes X O11 Yes X O12 No O13 No O14 No Text file All the parameters are listed Series 20 & 40

16 Editing a report Word file Series 80 Cover page Contents
Sepam software CD Overview of the software Parameter setting Editing a report Word file Cover page Contents Series 80 Structure presentation of parameters

17

18 Customizing the label Enter the required label for each indicator
Sepam software CD Overview of the software Parameter setting Customizing the label Enter the required label for each indicator

19 Printing labels Print Sepam software CD Overview of the software
Parameter setting Printing labels Print

20 Advanced settings Series 40 & 80
Sepam software CD Overview of the software Parameter setting Advanced settings Series 40 & 80 Access to additional settings which are not compulsory but may be used on function operation

21 PARAMETER SETTING Parameter setting

22 Full parameter setting
Sepam software CD Overview of the software Parameter setting Full parameter setting Some operations may be done before others, which is why we propose the following sequence: Define Sepam hardware setup Define Sepam hardware environment Define automation functions used Assign inputs / outputs Set protection functions Create mimic diagrams (series 80) Create logic equations (series 40 & 80) Set up Logipam (series 80) Validate control matrix Define disturbance recording function

23 1. Define Sepam setup Series 20 Sepam name Sepam model
Sepam software CD Overview of the software Parameter setting 1. Define Sepam setup Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 20 Sepam name 20 characters max. Sepam model with or without fixed advanced UMI Optional modules optional inputs / outputs temperature acquisition analog output communication

24 1. Define Sepam setup Series 40 Sepam name Sepam model
Sepam software CD Overview of the software Parameter setting 1. Define Sepam setup Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 Sepam name Sepam model Optional modules

25 1. Define Sepam setup Series 80 Sepam name Sepam model
Sepam software CD Overview of the software Parameter setting 1. Define Sepam setup Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Sepam name Sepam model Optional modules

26 2. Define Sepam environment
Sepam software CD Overview of the software Parameter setting 2. Define Sepam environment Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 20 Frequency Active group of settings Remote setting enabling Sepam working language Sensors

27 2. Define Sepam environment
Sepam software CD Overview of the software Parameter setting 2. Define Sepam environment Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 Frequency Active group of settings Remote setting enabling Sepam working language Sensors Type of cubicle External counters

28 P+ 2. Type of cubicle Series 40 & 80 Incomer Feeder
Sepam software CD Overview of the software Parameter setting 2. Type of cubicle Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 & 80 Incomer Power supplied to the busbars is positive. Feeder Power exported by the busbars is positive. Direction of flow P+

29 2. Define Sepam environment
Sepam software CD Overview of the software Parameter setting 2. Define Sepam environment Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Frequency Active group of settings Remote setting enabling Sepam working language Type of cubicle External counters Phase rotation direction Supply voltage monitoring and …

30 2. Define Sepam environment
Sepam software CD Overview of the software Parameter setting 2. Define Sepam environment Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Sensors 2. as well as …

31 2. Define Sepam environment
Sepam software CD Overview of the software Parameter setting 2. Define Sepam environment Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Specific load characteristics transformer: SFT2841 calculates In and Ib according to rated voltage and power machines capacitor

32 3. Define automation functions used
Sepam software CD Overview of the software Parameter setting 3. Define automation functions used Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 20 CB control Protection units excluded from CB control Logic discrimination

33 3. Define automation functions used
Sepam software CD Overview of the software Parameter setting 3. Define automation functions used Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 CB control Logic discrimination

34 3. Define automation functions used
Sepam software CD Overview of the software Parameter setting 3. Define automation functions used Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Switchgear control Logic discrimination And, according to applications Restart Load shedding De-excitation Genset shutdown Automatic transfer Capacitor step control

35 3. Define automation functions used
Sepam software CD Overview of the software Parameter setting 3. Define automation functions used Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 CT circuit supervision VT circuit supervision

36 3. Define automation functions used
Sepam software CD Overview of the software Parameter setting 3. Define automation functions used Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 CT circuit supervision VT circuit supervision

37 4. Assign inputs / outputs
Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 20 Inputs Outputs

38 4. Assign inputs / outputs
Sepam software CD Overview of the software Parameter setting 4. Assign inputs / outputs Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 Inputs Outputs Standard assignment of logic inputs according to the type of application described in the "Control and monitoring function" chapter of the documentation

39 4. Assign inputs / outputs
Sepam software CD Overview of the software Parameter setting 4. Assign inputs / outputs Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Inputs Outputs Assignment of other uses of logic inputs all "not used" inputs are assigned to "other use" if inputs are used in Logipam, they are assigned automatically The inputs/outputs used by Logipam are displayed in yellow

40 5. Set protection functions
Sepam software CD Overview of the software Parameter setting 5. Set protection functions Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 20 Choice of protection functions Activation Setting Control matrix

41 5. Set protection functions
Sepam software CD Overview of the software Parameter setting 5. Set protection functions Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 Choice of protection functions Activation Setting Control matrix Define whether the unit is latched affects CB control

42 5. Set protection functions
Sepam software CD Overview of the software Parameter setting 5. Set protection functions Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 This screen displays protection functions in service which sensors are used by the protection functions

43 5. Set protection functions
Sepam software CD Overview of the software Parameter setting 5. Set protection functions Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Choice of protection functions Activation Setting Control matrix Define whether the unit is latched affects CB control

44 5. Timer hold Definitions: Applications:
Sepam software CD Overview of the software Parameter setting 5. Timer hold Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Definitions: Timer hold: time added to reset time to: delay the return to the initial situation and activate a memory for the detection of recurrent faults. Reset time (of a protection function): time of return to the initial situation of a protection function after the disappearance of the fault (<50ms) Applications: definite time: detection of recurrent faults on networks earthed by a Petersen coil (for directional earth fault protection) IDMT: used to have a reset time similar that of a disc-type electromechanical relay for improved discrimination when the relay is situated upstream.

45 5. Timer hold Influence on tripping time 100% of tripping delay Time
Sepam software CD Overview of the software Parameter setting 5. Timer hold Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Influence on tripping time 100% of tripping delay Time I > Is timer hold = 0 IDMT timer hold definite-time timer hold

46 5. H2 restraint Stability upon transformer energizing
Sepam software CD Overview of the software Parameter setting 5. H2 restraint Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Stability upon transformer energizing This function should only be activated with Σ 3I earth fault protection upstream from a transformer Transformer energizing generates number 2 harmonics . This function restrains the protection if the harmonic is above the set 17% threshold. H2 > seuil I1 I2 I3 TC + CSH30 CSH120 ou 200 Tore + ACE990 Σ Signal "pick up" Sortie temporisée Io > Iso t 0 Schéma de principe protection 50N/51N

47 5. CT saturation caused by transformer energizing
Sepam software CD Overview of the software Parameter setting 5. CT saturation caused by transformer energizing Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording I1 I2 I3

48 5. Io = I1+I2+I3 Sepam software CD Overview of the software
Parameter setting 5. Io = I1+I2+I3 Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording

49 6. Create mimic diagrams Series 80
Sepam software CD Overview of the software Parameter setting 6. Create mimic diagrams Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Will be explained in the "Mimic-based UMI" chapter 5.

50 7. Create logic equations
Sepam software CD Overview of the software Parameter setting 7. Create logic equations Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 & 80 Will be explained in the "Equation editor" chapter

51 8. Set up Logipam Series 80 Selection of the program Activate Logipam
Sepam software CD Overview of the software Parameter setting 8. Set up Logipam Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Selection of the program the files are placed in the following directory: C:\ProgramFiles\Schneider\ SFT2841\Logipam Activate Logipam

52 8. Set up Logipam Series 80 Set up internal bits Sepam software CD
Overview of the software Parameter setting 8. Set up Logipam Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Set up internal bits

53 8. Set up Logipam Series 80 Set time delays Sepam software CD
Overview of the software Parameter setting 8. Set up Logipam Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Set time delays

54 9. Validate control matrix
Sepam software CD Overview of the software Parameter setting 9. Validate control matrix Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 20 Column 1: input resources protection function delayed outputs logic inputs miscellaneous information Row 1: output resources logic outputs indicators activation of disturbance recording grey: not modifiable black: unavailable red: off white: on

55 9. Validate control matrix
Sepam software CD Overview of the software Parameter setting 9. Validate control matrix Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 & 80 The principle and the rules are the same as for those for series 20 Since there are more data items, the matrix is split into several screens grey: not modifiable black: unavailable red: off white: on

56 9. Customize messages Series 40 & 80
Sepam software CD Overview of the software Parameter setting 9. Customize messages Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 & 80 Double-click on the message to be customized Create the message Double-click on the new message Enter the message

57 9. Assign messages Series 40 & 80
Sepam software CD Overview of the software Parameter setting 9. Assign messages Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 & 80 Double-click on the message to be customized Select the new message by clicking on the number Assign the message

58 10. Define disturbance recording function
Sepam software CD Overview of the software Parameter setting 10. Define disturbance recording function Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording This function supplies a file: created by a trigger composed of the recording of analog signals and logic states (COMTRADE format) Recording begins before the trigger and continues after the event (according to parameter setting) stored recording time trigger number of pretrig periods

59 10. Define disturbance recording function
Sepam software CD Overview of the software Parameter setting 10. Define disturbance recording function Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 20 Non-modifiable characteristics max. of 2 stored recordings 86 periods 4 current or voltage channels 10 logic inputs output O1 pick-up Setting of pretrig

60 10. Define disturbance recording function
Sepam software CD Overview of the software Parameter setting 10. Define disturbance recording function Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 40 Non-modifiable characteristics all analog channels 10 logic inputs outputs O1 to O4 pick-up 1 equation editor variable Setting according to memory allocated number of recordings duration of each recording Setting of pretrig

61 10. Define disturbance recording function
Sepam software CD Overview of the software Parameter setting 10. Define disturbance recording function Sepam hardware setup Sepam hardware environment Automation functions used Inputs / outputs Protection functions Mimic diagram (series 80) Logic equations (series 40 & 80) Logipam (series 80) Control matrix Disturbance recording Series 80 Non-modifiable characteristics all analog channels Setting according to memory allocated number of recordings duration of each recording sampling frequency Setting of pretrig Selection of recorded logic states

62 MAIN POINTS TO REMEMBER
faire "ce qu'il faut retenir"

63 A compléter

64 Astuces de paramétrage
Faire attention que le type de fichier corresponde au type de Sepam Ne pas oublier de mettre les protections en service Ne pas perdre le code de déverrouillage du SFT2841 qui se trouve sur la boite du CD d’installation. Penser à valider les sorties qui doivent être utilisées dans la matrice de commande. Le changement du type arrivée / départ modifie le signe de la puissance. La passage par la navigation guidée permet de ne pas oublier de configurer des écrans. Le SFT2841 vérifie la cohérence des valeurs rentrées en fonction des plages de réglage et du ratio des TC / TP


Download ppt "SFT2841 disconnected Prepare setting files Experts: L.GIGLI"

Similar presentations


Ads by Google