INVERTER PT-200 LOCATED IN STBD NOSE COMPARTMENT PROVIDES 36V AC THREE PHASE, 400HZ EQUIPMENT FAILURES DUE TO FAN COVER DAMAGE FAILURE OF BEARING MALFUNCTIONING.

Similar presentations


Presentation on theme: "INVERTER PT-200 LOCATED IN STBD NOSE COMPARTMENT PROVIDES 36V AC THREE PHASE, 400HZ EQUIPMENT FAILURES DUE TO FAN COVER DAMAGE FAILURE OF BEARING MALFUNCTIONING."— Presentation transcript:

1

2 INVERTER PT-200

3 LOCATED IN STBD NOSE COMPARTMENT PROVIDES 36V AC THREE PHASE, 400HZ EQUIPMENT FAILURES DUE TO FAN COVER DAMAGE FAILURE OF BEARING MALFUNCTIONING OF CENTRIFUGAL S/W RESISTORS OUT OF ADJUSTMENT FAILURE WILL CAUSE DE-ENERGISING OF 36V EMERGENCY BUS BAR

4 INVERTER PT-200 SERIES 4 LOCATION

5 INPUT VOLTAGE – 27V DC±2.7V INPUT CURRENT – 14.0 AMPS OUTPUT VOLTAGE – 35.5 TO 40.0V AC THREE PHASE, SINE WAVE AC LOAD CURRENT – 3.2 AMPS OUTPUT FREQUENCY – 400 HZ±2% OUTPUT POWER – 200VA EFFICIENCY – 31.7% MINIMUM POWER FACTOR – 0.6 (INDUCTIVE) OPERATING TEMPERATURE - ±60°C ALTITUDE FOR CONTINUOUS OPERATION UPTO 15,000 M -RATED LOAD 18000 M -75% LOAD WEIGHT – 08.6 KG ADDITIONAL REQUIREMENTS – REMOTE ON/OFF AND OVERLOAD PROTECTION TECCHNICALTECCHNICAL SPECIFICATIONSSPECIFICATIONS

6 EQUIPMENT ELECTRO-MECHANICAL AND ROTARY IN NATURE REQUIRED TO BE REPLACED WITH SOLID STATE STATIC VERSION DESIGN CLEARANCE FROM CEMILAC THE REQUIREMENT FOR FIVE YEARS IS 250