Download presentation
Presentation is loading. Please wait.
Published byCleopatra Blake Modified over 9 years ago
1
Neutron Dose Per Fluence and Weighting Factors for Use at High Energy Accelerators (Submitted to Health Physics) J. Donald Cossairt, Ph.D., C.H.P. Kamran Vaziri, Ph.D. Fermi National Accelerator Laboratory Batavia, IL Operated by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the United States Department of Energy.
2
2 The Problem Work motivated by 10 CFR 835 amendments announced June 2007 Instituted newer ICRP recommendations (ICRP 60, ICRP 68) External dose from neutrons most serious problem at accelerators Neutron weighting factors (a.k.a. quality factors) are modified upward 10 CFR 835 now provides no dose per fluence factors
3
3 The Problem Solution is needed To understand instrument calibrations To perform correct shielding calculations To achieve compliance in posting of areas This work (also available as a preprint) Surveyed literature Pursued more recent ICRP recommendations Applied results to 241 Am-Be spectra Applied results to accelerator neutron spectra Ignores DOELAP (for now!) Ignores internal exposure
4
4 Quantities In the “good old days” : connecting absorbed dose D with dose equivalent H equiv ; D = energy/mass Old 10 CFR 835 had table of QF and H equiv per fluence values –Identical to that in NCRP Report 38 –With unit conversion, was identical to 10 CFR 20. Still have the form of above Equation, with several different dosimetry quantities replacing “ H ”
5
5 Table from old 10 CFR 835
6
6 Quantities (“nutshell” definitions) Protection Quantities (theoretical, used for limits and standards) Equivalent dose = absorbed dose in an organ weighted by radiation weighting (a.k.a “quality”) factor; E equiv Effective dose = Sum of equivalent doses over the whole body weighted by organ weighting factors (includes both internal and external dose, ignored internal here); H eff
7
7 Quantities (“nutshell” definitions) Operational Quantities (measurable, perhaps, used to demonstrate compliance) Ambient dose equivalent = dose equivalent on a radius of the “ICRU” sphere (30 cm diam, 1 g cm -1 of “tissue equivalent material) at depth d ; H amb (d) Personal dose equivalent = equivalent dose in soft tissue measured at depth d ( d = 1 cm for whole body) ; H pers (d) 10 CFR 835 specifically connects H pers (d) with control of H eff
8
8 Literature Search: Dose per Fluence Connect “dose”, H, with fluence, (neutrons cm -2 ), e.g.; Need over wide domain of neutron energy E n ; thermal to almost the beam energy
9
9 Literature Search: Dose per Fluence Concentrated on H eff, P eff (pSv cm 2 ) Side issue with H eff, need “geometries” ROT = body on axis “the long way”, irradiated from the side (think shish-kabob) ISO = “isotropic” irradiation Neither are perfect for occupational setting, both better than the alternatives, fixed orientations
10
10
11
11
12
12
13
13 Fits to H eff Sutton-Ferenci (Hertel Group) : 10 -9 to 2000 MeV
14
14 Fits to H eff Ferrari et al. (Pelliccioni Group) : > 2000 MeV Preprint includes tabular values of merged set in preprint.
15
15 Literature Search: Weighting Factors “Old” values from 10 CFR 835, NCRP 38, etc.; QF old [Note from ICRP: we can still use the terms “quality factor”, or “effective quality factor”!] ICRP 60 (1990) gives: ICRP 103 (2007) gives:
16
16
17
17 Now to Apply This! 241 Am-Be Neutron Spectra To understand effects of change on instrument calibrations Fermilab Accelerator Neutron Spectra Average QF might change, need to reset preset values in “Chipmunk” ion chamber monitors; also “Snoopies”, “REM-500s”. Background information for possible policy changes, some related to “occupancy”
18
18 241 Am-Be Neutron Spectra Lots of spectra around Difficult to measure, energy of neutrons of in region of many energy-dependent detector efficiencies and thresholds resonances Source construction can matter Used 2 spectra of high quality ISO 8529-1 (2001) DeGuarrini and Malaroda (1971)
19
19
20
20 241 Am-Be Neutron Spectra Calculated Average energies Average “weighting factors” Done by numerical integration over 0.1 MeV bins Used P eff values from equations above Did same way for H equiv to get ICRP 60 and ICRP 103 results were identical; due to limited energy domain
21
21 241 Am-Be Neutron Spectra Does NOT include photons, scattered neutrons, etc.! These all tend to reduce the.
22
22
23
23 Fermilab Accelerator Neutron Spectra Reanalyzed 9 neutron spectra measured at Fermilab (lettered A-I) Compared “old” with ICRP 60 and ICRP 103 schemes Details of spectra described in the preprint and some elsewhere All were inferred from Bonner Spheres
24
24 Fermilab Accelerator Neutron Spectra Extracted neutrons per bin from “lethargy” plots Applied ICRP 60, ICRP 103, and “old” weighting factors bin-by-bin Found average values of weighting factors for each spectra Obtained “cumulative” plots
25
25
26
26
27
27
28
28
29
29
30
30
31
31 Fermilab Accelerator Neutron Spectra
32
32 Conclusions Average weighting factor for 241 Am-Be is 52% higher with “new” methodology. Instrument calibrations will need alteration Must allow for photons in spectrum! For accelerator spectra Weighting factor increased from 4.8 to 6.1 using ICRP 103, relatively small change. No average weighting factor > 10 with ICRP 103. Most posted areas are minimal occupancy Will need to rethink a few high occupancy areas.
33
33 Contact Information Phone: 630-840-3465 Email: cossairt@fnal.gov
Similar presentations
© 2024 SlidePlayer.com Inc.
All rights reserved.