1 Direct-acting room heaters WHICH IS THE BEST WAY TO VERIFY AND CERTIFY OUR PRODUCT'S PERFORMANCE?

2 WHAT IS IT? IT IS A THIRD PART APPROVAL ISSUED BY THE FRENCH NATIONAL CERTIFICATION BODY "LCIE"

3 WHY IS IT IMPORTANT? BECAUSE FRANCE REPRESENTS THE REFERENCE MARKET FOR ELECTRIC HEATING AND LCIE HAS DEVELOPED INTERESTING AND OBJECTIVE METHODS TO CHECK HEATING PRODUCTS PERFORMANCE.

4 WHICH ARE REFERENCE STANDARDS? APPLICABLE STANDARDS ARE: EN60335-1 "Hosehold and similar electric appliances - Safety General Requirements" EN60335-2-30 "Particular requirements for room heaters" EN 60335-2-43: "Particular requirements for clothes dryers and towel rails" EN60675:"Household electric direct-acting room heaters: Methods for measuring performance" LCIE 103-13 "Cahier des charges de la marque NF Electricitè Performance"

5 NF PERFORMANCE REQUIREMENTS 1 - ENVIRONMENT 2 - SAFETY & RELIABILITY 2.1 - PROTECTION AGAINST ELECTRIC AND THERMAL SHOCKS 2.2 - AIR OUTLET TEMPERATURE 2.3 - SURFACE TEMPERATURE 2.4 - HEATING ELEMENT(S) RELIABILITY 3 - PARTICULAR REQUIREMENTS

6 1 - ENVIRONMENT THE PRODUCT SHOULD NOT MAKE THE WALL DIRTY IN STEADY CONDITION AT NOMINAL POWER THE TEMPERATURE RISE OF THE SURFACE OVER THE HEATER SHOULD NOT BE OVER 20°C

7 2 - SAFETY & RELIABILITY 2.1 - PROTECTION AGAINST ELECTRIC AND THERMAL SHOCKS ACCESSIBILITY TESTS ARE MADE WITH PROBES DIFFERENT FROM THE ONES USED DURING SAFETY APPROVAL

8 2 - SAFETY & RELIABILITY 2.2 - AIR OUTLET TEMPERATURE AIR OUTLET GRID TEMPERATURE RISE: MAX 100°C

9 2 - SAFETY & RELIABILITY 2.3 - SURFACE TEMPERATURE TEST CONDITIONS THE PRODUCT IS RUN AT NOMINAL POWER INSIDE THE TEST ROOM. THE THERMOSTAT IS SET TO MAINTAIN A TEMPERATURE OF ABOUT 20±2°C A COLD AIR FLOW INSIDE THE TEST ROOM IS MODULATED SO THAT THE POWER CONSUMPTION NECESSARY TO MAINTAIN SET ROOM TEMPERATURE IS ABOUT: 20% OF MAXIMUM NOMINAL POWER TO SIMULATE REDUCED HEATING NEEDS 80% OF MAXIMUM NOMINAL POWER TO SIMULATE RELEVANT HEATING NEEDS

10 PRODUCT FUNCTIONING CHARACTERISTICS SHOULD BE THE SAME BOTH IN CASE OF HEAVY OR LIGHT HEATING NECESSITY.  20%  80%

11 SURFACE TEMPERATURE DISPERSION DIFFERENCE BETWEEN TEMPERATURE MEASURED IN DIFFERENT POINTS BOTH AT 20% AND 80% SHOULD NOT EXCEED 30°C SURFACE TEMPERATURE STABILITY DIFFERENCE BETWEEN THE MAX TEMPERATURE MEASURED IN EVERY POINT BOTH AT 20% AND 80% SHOULD NOT EXCEED 15°C

12 2 - SAFETY & RELIABILITY 2.4 - HEATING ELEMENT(S) RELIABILITY T1=MAX TEMP OF THE H.E. @ 244V T2=0.75 T1 2500 CYCLES @ 400V TIME CYCLE IS SET TO MAINTAIN H.E. TEMP IN THE RANGE T1-T2

13 3 - PARTICULAR REQUIREMENS 3.1 ROOM TEMPERATURE DRIFT MAX 1,5°C 20% 80%

14 3 - PARTICULAR REQUIREMENS 3.2 ROOM TEMPERATURE AMPLITUDE MAX 0,5°C 20% 80%


Download ppt "Direct-acting room heaters WHICH IS THE BEST WAY TO VERIFY AND CERTIFY OUR PRODUCT'S PERFORMANCE?"