Advance Design of RC Structure University of Palestine Lecture 2 Seismic loads Dr. Ali Tayeh

2 General Introduction The seismic forces in a structure depend on a
number of factors including the:- Size & other characteristics of the earthquake Distance from the fault Site geology Type of lateral load resisting system The use & the consequences of failure of the structure There are two commonly used procedures for specifying seismic design forces The equivalent static force procedure Dynamic analysis

3 There are several analytical procedures to determine the magnitude of the base shear for which buildings must be designed, we will only consider the equivalent lateral force procedure

4 The equivalent static force procedure
In this method the inertia forces are specified as static force using empirical formulas. The formula developed to adequately represent the dynamic behavior of what are called “regular” structures. This method of analysis can be used if the structure is: Regular structure under 240 feet (73meters) tall Irregular structure under 65 feet (20meters) Regular structure means; A structure having reasonable uniform distribution of a mass and stiffness Uniform shape Uniform statical system Irregular Structure Irregular Structure

5 Dynamic Analysis A dynamic analysis can take a number of forms, but should account for the irregularities of the structure by modeling its “dynamic characteristics” including natural frequencies mode shapes and damping. This method of analysis can be used if the structure is; Regular over 240 feet tall Irregular structure over 65 feet Located on poor soils & have a period greater than 0.7 seconds.;

6 Design Base shear V T is the fundamental period of the structure in the direction under consideration I is the seismic important factor CV is a numerical coefficient dependent on the soil conditions at the site & the seismicity of the region W is the seismic dead load R is factor which accounts for the ductility & over strength of the structure system

7 Design Base shear V The design base shear need not exceed :
And cannot be less than Where Ca is another seismic co-efficient depend on the soil conditions at the site & regional seismicity Additionally in the zone of highest seismicity (zone 4) the design base shear must be greater than

8 Seismic Zone Factor 4 3 2B 2A 1 Zone 0.4 0.3 0.2 0.15 0.075 Z
Where Nv is a near-source factor that depend on the proximity to & activity of known faults near the structure. Also Nv used in determining the seismic co-efficient Cv for building located in seismic zone 4 Seismic Zone Factor The zone for a particular site is determined from a seismic zone map. The numerical value of Z are: 4 3 2B 2A 1 Zone 0.4 0.3 0.2 0.15 0.075 Z

9 Fundamental natural period =
Important Factor The importance factor I is used to increase the margin of safety for essential and hazardous facilities See Table 1 in the handout sheets Building Period Fundamental natural period = Where Ct = for steel moment frames 0.030 for concrete moment frames 0.030 for eccentric braced frames 0.020 for all other buildings hn = The height of the building in feet

10 Structure System Coefficient R
The structural system coefficient, R is a measure of the ductility and over strength of the structural system, based primarily on performance of similar systems in past earthquakes. See Table 2 in the handout sheets

11 Seismic Coefficients Cv & Ca
Seismic Dead Load W All the dead load of the structure including the partitions, total load not less than 10psf (0.48kN/m2), plus 25% of the floor live load in storage & warehouse occupancies Where design snow loads exceed 30 psf (1.44kN/m2) the design snow load shell be included Total weight of permanent equipment shall be included Seismic Coefficients Cv & Ca Depend on the expected ground acceleration at the site & that’s depend on the seismic zone & soil profile type See Table 3 & 4

12 Soil Profile Type S The effect of soil condition at the site on ground motion See Table 5

13 Seismic Source Type A, B & C
It is used only in seismic zone 4 to specify the capacity & activity of faults in the immediate vicinity of the structure. See Table 6 Near Source Factors Na & Nv It is used only in seismic zone 4 to determine the seismic coefficients Cv & Ca See Table 7 & 8

14 Distribution of Lateral Force FX
The base shear V determined from previous equations are distributed over the height of the structure as a force at each level Fi, plus an extra force Ft at the top The extra force at the top is Ft = 0.07TV  0.25V if T  0.7 sec Ft = if T  0.7 sec

15 The remaining portion of the total base shear (V-Ft) is distributed over the height including the top by the formula: Where W is the dead load of the (i) level including the partitions & 25% of the floor live load in storage & warehouse occupancies h is the height of the (i) level above the shear base

16 Story Shear Overturning Moment
The shear at any level x is the sum of all story forces at & above that level Overturning Moment The shear at any level x is the sum of all story forces at & above that level

17 Resisting Moment = W B/2
Factor of safety =

18 Over Turning Moment Force Diagram Shear Diagram

19 Reliability/redundancy factor 
The seismic base shear determined from the previous equations must be multiplied by a reliability/redundancy factor for the later load resisting system AB is the ground floor area of the structure in square meter rmax is the maximum element-story shear ratio. For shear walls rmax shell be taken as the maximum value of the product of the wall shear multiplied by 3.05/lw & divided by the total story shear, where lw is the length of the shear wall in meter.

20 Displacement and Drift
For special moment-resisting frames, if  exceeds 1.25, additional bays must be added. Seismic Zone 0, 1 & 2  = 1 Displacement and Drift The calculated story drifts are computed using the maximum inelastic response displacement drift (m), which is an estimate of the displacement that occurs when the structure is subjected to the design basis ground motion

21 S = design level response displacement, which is the total drift or total story drift that occurs when the structure is subjected to the design seismic forces. Calculated story drift shall not exceed times the story height for structures having a fundamental period of less than 0.70 seconds. Calculated story drift shall not exceed times the story height for structures having a fundamental period equal to or greater than 0.70 seconds.

22 Example 1 Determine the UBC-97 design seismic forces for six story concrete shear wall office building. Located in seismic zone 3 on rock,. The story dead load is 850 kg/m2. live load 300 kg/m2 7m3 Plan 3m6story Elevation

23 Solution Cv = 0.3 Table 3 Z = 0.3 , SB Ct = 0.020 other building
Base shear: I = 1.0 Table 1 special occupancy structures R = 5.5 Table 2 for shear wall-frame interaction system Zone factor Z = 0.3 for seismic zone 3 Soil profile type SB Table Rock ground Cv = Table Z = 0.3 , SB Ct = 0.020 other building hn = 3m  6story = 18m  59ft

24 The Base shear W = Dead load  each floor area  Number of story
Presumed partitions and columns weight are accounted in the dead load per m2 . No live load would accounted with W W = 0.85  441  6 = 2249 ton The Base shear

25

26 Vertical Distribution
T  0.7 sec Ft = 0.0

27 F1= 4.53  3 = 13.6 ton F4= 4.53  12 = 54.4 ton F2= 4.53  6 = 27.2 ton F5= 4.53  15 = 68.0 ton F3= 4.53  9 = 40.8 ton F6= 4.53  18 = 81.5 ton If Ft  0. then the top floor will have two forces Ft + F6

28 Story Shear Overturning Moment
V6 = 81.5 ton V3 = = ton V5 = = ton V2 = = ton V4 = = ton V1 = = ton Thus the shear force at the base = ton Overturning Moment

29 Thus the moment at the base = 3711 ton.m
M6 = 81.5  3 = ton.m M5 = 81.5   3 = 693 ton.m M4 = 81.5    3 = ton.m M3 = 81.5     3 = ton.m M2 = 81.5     3 = ton.m M1 = 81.5   9+27.26+13.63 = ton.m Thus the moment at the base = 3711 ton.m

30 Resisting Moment Factor of safety = Resisting moment = W Total  B/2
= 0.85  441  6  21/2 = 23615,5 ton.m Factor of safety =

31 Summery Mx Vx Fx Wihi hi Wi Floor 244.5 81.5 6747.3 18 374.85 6 693.0
149.5 68.0 15 5 1304.7 203.9 54.4 4498.2 12 4 2038.8 244.7 40.8 9 3 2854.5 271.9 27.2 2249.1 2 3711.0 285.5 13.6 1

32 0.0 81.5 244.5 68.0 693.0 54.4 1304.7 40.8 2038.8 27.2 2854.5 13.6 3711 Moment Diagram Shear Diagram Elevation