Presentation is loading. Please wait.

Presentation is loading. Please wait.

Reconnaissance and Surveillance Leader Course MODULE 4 AN/PRC-117F LOS FIXED FREQUENCY OPERATION.

Similar presentations


Presentation on theme: "Reconnaissance and Surveillance Leader Course MODULE 4 AN/PRC-117F LOS FIXED FREQUENCY OPERATION."— Presentation transcript:

1 Reconnaissance and Surveillance Leader Course MODULE 4 AN/PRC-117F LOS FIXED FREQUENCY OPERATION

2 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Objectives: –Program the AN/PRC-117F for LOS Fixed Frequency operation. Plain text nets Cipher text nets Voice or Data operation –Operate the AN/PRC-117F as a station in a LOS Fixed Frequency Net. LOS Fixed Frequency Nets

3 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation LOS Fixed Frequency Nets allow the user to receive and transmit voice and/or data using fixed receive and transmit frequencies. –30 MHz - 89.99999 MHz VHF-Low Band, FM only VINSON COMSEC, voice or data using FM KG-84, DATA only, FM or TCM –90 MHz - 224.99999 MHz VHF-High Band and 225 MHz - 512 MHz UHF Band VINSON, voice or data using AM or FM Fascinator COMSEC, FM Modulation, Voice mode only KG-84 Encryption for DATA only, AM, FM, TCM LOS Fixed Frequency Nets

4 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Up to 100 nets can be programmed into the radio. Net names consist of 12 alphanumeric characters. –Spaces not allowed. –Default names for each net is NET##, where ## represents a number 00 to 99. Each net can be enabled or disabled during programming at the ACTIVATE IN LIST? Prompt. –Choosing NO makes net inaccessible with PRE+/- button. It is callable by entering the channel number. Type of net must be selected before the net is programmed: –LOS Fixed Frequency Net –Dedicated UHF SATCOM Net –Frequency Hopping Net, SINCGARS or HAVE QUICK AN/PRC-117F Net Programming Considerations

5 Reconnaissance and Surveillance Leader Course PGM NORM ACTIVATE IN LIST NET TYPE LOS FIXED FREQUENCY NET SELECT NET TO MODIFY 00 - 99 YES NO FREQCOMSECDATA/VOCSQUELCHPOWERNAME NORM DAMA SCAN PORTS SECUR CFIG USE <> TO SELECT ITEM PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM LOS Fixed Frequency Programming

6 Reconnaissance and Surveillance Leader Course RECEIVE FREQUENCY # # #.# # # # # TRANSMIT FREQUENCY # # #.# # # # # RECEIVE ONLY? FREQ NO YES Simplex operation, set receive and transmit frequency to same value. Half duplex uses different receive and transmit frequencies. They must be the same band. Set RECEIVE ONLY? To YES for nets when you have no authorization to transmit. Radio will not allow entry of frequencies outside its frequency range of 30 MHz to 512 MHz. PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM LOS Programming, Frequency

7 Reconnaissance and Surveillance Leader Course COMSEC CRYPTO MODE NONE VINSON ENCRYPTION KEY TEK 01 - 25 KG-84 FASCINATOR ENCRYPTION KEY TEK 01 - 25 ENCRYPTION KEY* TEK 01 - 25 KG-84 COMSEC only available in DATA. FASCINATOR encryption not available in the VHF-low band (30 MHz - 90 MHz) Voice only. * VINSON and Fascinator share the same bank of 25 encryption keys. 64K LOS Data requires KG-84. PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM Programming, COMSEC ANALOG DATA YES NO ANALOG DATA YES NO SYNCHRONIZATION REDUN MODE 1 REDUN MODE 2 NON-REDUN MODE 3 NON-REDUN MODE 4

8 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation ADF port J-1 connector Data port J-3 connector Data rate – 16 kbps ASYNC data requires data port configuration. FM Deviation –8 kHz – Standard Tactical FM –6.5 kHz – SINCGARS Family SC operation –5.0 kHz – 5 & 6.25 kHz BW Channel Handhelds PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM DATA/VOC FM DEVIATION 8.0 kHz 6.5 kHz 5.0 kHz LOS Programming, DATA/VOC Using VINSON COMSEC AUTO ON ADF PORT SYNC/ASYNC SELECT ASYNC SYNC AM FM MODULATION FM DEVIATION 8.0 kHz 6.5 kHz 5.0 kHz AUTO ON DATA PORT SYNC/ASYNC SELECT ASYNC SYNC AM FM MODULATION

9 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation TCM – Trellis Coded Modulation, HI-Speed LOS Data operation requires KG-84 encryption. ASYNC data operation requires data port configuration. SYNC data operation uses very common default port settings LOS Programming, DATA/VOC DATA FM DEVIATION 8.0 kHz 6.5 kHz 5.0 kHz SYNC/ASYNC SELECT ASYNC SYNC FM MODULATION TCM SYNC/ASYNC SELECT ASYNC SYNC FM DEVIATION 8.0 kHz 6.5 kHz 5.0 kHz BAUD RATE 64.0 K 48.0 K KG-84C selected PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM DATA/VOC AM

10 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Fascinator COMSEC – Voice only, FM only above 90 MHz. LOS Programming, DATA/VOC VOICE FM DEVIATION 8.0 kHz 6.5 kHz 5.0 kHz Fascinator selected PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM DATA/VOC

11 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Digital Squelch only available in Cipher Text (CT) mode for VOICE. AM analog squelch with three levels of sensitivity. Tone Squelch (150 Hz sub- audible), only available in the 30 MHz to 90 MHz VHF-Low Band. Squelch programming becomes unavailable when KG-84 COMSEC is selected. PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM SQUELCH DIGITAL SQUELCH (CT) ON OFF ANALOG SQUELCH OFF TONE NOISE OFF ON AM FM HIGH MEDIUM LOW LOS Programming, SQUELCH

12 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation POWER TX POWER LEVEL 1 WATT 1.3 WATTS 1.6 WATTS 2 WATTS 2.5 WATTS 3 WATTS 4 WATTS 5 WATTS 6.3 WATTS 10 WATTS 13 WATTS 16 WATTS 20 WATTS Use power level necessary to establish communications. 20 Watts –90 MHz – 399.99999 MHz, FM or TCM only 10 Watts –30 MHz – 89.99999 MHz –400 MHz – 512 MHz –All AM 1 dB incremental adjustment steps. PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM LOS Programming, POWER

13 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation NAME CHANGE NET NAME ABC123... Net Names can be up to 12 character alphanumeric with no spaces allowed. PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM LOS Programming, NAME

14 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation NET TYPE LOS FIXED FREQUENCY FREQCOMSECDATA/VOCSQUELCHPOWERNAME NET TYPE DEDICATED SATCOM FREQ CODECOMSECDATA/VOCSQUELCHPOWERNAME NET TYPE HAVE QUICK FH HQ_NET_NUMCOMSECDATA/VOCSQUELCHPOWERNAME NET TYPE SINCGARS FH NET IDCOMSECDATA/VOCPOWERNAME

15 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Turn radio on to PT, allow POST to complete. Press PGM key on KDU. Select NORM and press [ENT]. Choose NET and press [ENT]. Press number key for Net to modify. Use 00-99. Start with 00 for NET00. NORM DAMA SCAN PORTS SECUR CFIG USE <> TO SELECT ITEM NET GENERAL USE <> TO SELECT ITEM SELECT NET TO MODIFY 00 [NET0 ] LOS Fixed Frequency Programming

16 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation For ACTIVATE IN LIST, choose YES to have Net accessible by the PRE +/ - Key. Press [ENT]. For NET Type, choose ‘LOS FIXED FREQUENCY’ from selections of: –LOS FIXED FREQUENCY –FREQUENCY HOPPING –SATCOM Press [ENT] to access LOS net sub menu. Use the right arrow key and scroll around to FREQ. ACTIVATE IN LIST? YES NET0 NET TYPE LOS FIXED FREQUENCY NET0 PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM LOS Fixed Frequency Programming

17 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Press [ENT] to access LOS net sub menu. Choose FREQ to set net operating frequencies. Press numeral keys to enter desired operating frequency. For this example, enter in order, 0, 4, 6, 5, 7, 5 to obtain on the display: 046.57500 MHz. Press [ENT] to set in receive frequency, and display switches to transmit frequency. PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM PT RECEIVE FREQUENCY 030.00000 MHz NET0 PT RECEIVE FREQUENCY 046.57500 MHz NET0 LOS Fixed Frequency Programming

18 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Press [ENT] to set in same transmit frequency, receive for simplex operation, or enter in different transmit frequency for half-duplex operation. For half-duplex operation, both receive and transmit frequency must be in the same band. After T/R frequencies are entered, radio display shows RECEIVE ONLY. Choose NO for transmit and receive capability. YES is for giving the radio a listen only capability for that net. Radio goes back to sub-menu. Use right arrow and select COMSEC. PT TRANSMIT FREQUENCY 046.57500 MHz NET0 PT RECEIVE ONLY NO NET0 LOS Fixed Frequency Programming PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM

19 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Under CRYPTO Mode, use up/down arrows to scroll through choices of FASCINATOR, VINSON and KG-84. Choose VINSON for this Net. Press [ENT] to move on down the COMSEC menu tree. The encryption key screen appears. Enter in the key number for the COMSEC type previously selected. Keys were loaded initially for operation under each type of COMSEC. Proper values are from 01 to 25. Select TEK 01. Press [ENT] and radio returns back to LOS Net sub-menu. PT CRYPTO MODE VINSON NET0 PT ENCRYTION KEY TEK 01 NET0 PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM LOS Fixed Frequency Programming

20 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Press > right arrow key to select DATA/VOC and press [ENT]. The displays moves to DATA/VOICE. For FASCINATOR, only VOICE is selectable. Under VINSON type COMSEC, AUTO on ADF PORT or AUTO ON DATA PORT is selectable. For KG-84, DATA is the only choice. Use up/down arrows to select AUTO ON ADF PORT. Press [ENT] to set this selection. Modulation type is next on the menu. It is dependent on previous settings for COMSEC type or frequency band. Choices are AM, FM or TCM, select FM and press [ENT]. PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM LOS Fixed Frequency Programming PT DATA/VOICE AUTO ON ADF PORT NET0 PT MODULATION FM NET0

21 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation After selection of FM Modulation, FM DEVIATION parameter must be set. –8.0 kHz, 6.5 kHz or 5.0 kHz Select 8.0 kHz for standard tactical FM operation and press [ENT]. Next, select default DATA operation type at ASYNC/SYNC DATA SELECT. Choose type for expected type of data operation. Radio returns back to LOS sub-menu. Use > right arrow and move on to SQUELCH. Press [ENT]. PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM LOS Fixed Frequency Programming PT FM DEVIATION 8.0 kHz NET0 PT ASYNC/SYNC SELECT SYNC NET0

22 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation DIGITAL SQUELCH is the next selection. This is only available in cipher text (CT). Use up/down arrows to select OFF and press [ENT] to set the choice and move on to ANALOG Squelch. If Digital squelch is set to OFF, then ANALOG SQUELCH TYPE selection becomes active. Use up/down arrows to select TONE from selections of OFF, TONE, and NOISE. Tone squelch is only available when using the 30-90 MHz frequency range. Press [ENT] to select and radio returns back to LOS sub-menu. PT ANALOG SQUELCH TYPE OFF NET0 PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM LOS Fixed Frequency Programming PT DIGITAL SQUELCH OFF NET0 PT ANALOG SQUELCH TYPE TONE NET0

23 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Use > right arrow key and move to POWER, press [ENT]. TX POWER LEVEL screen allows user to scroll through available power levels with the up/down arrows. Select 10 WATTS and press [ENT] to set your selection. Use the minimum setting required to communicate. Radio returns to LOS sub-menu. Use > right arrow key to move to NAME. Press [ENT] to access CHANGE NAME screen. PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM LOS Fixed Frequency Programming PT TX POWER LEVEL 10 WATTS NET0 PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM

24 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Nets can have 12 character alphanumeric names. Use keys to enter in Net name. Once name is correct, press [ENT] and set the name. Radio returns to the LOS Programming sub-menu. LOS Fixed Frequency Programming PT CHANGE NAME NET0 PT CHANGE NAME ARTY NET0 PT FREQ COMSEC DATA/VOC SQUELCH POWER NAME USE <> TO SELECT ITEM

25 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation After review, press [CLR] to back out to NET screen. Reselect NET to program another Net Preset. Enter in an unused net number to insure not to change any setting from previous NET preset. Radio will show name of this net. Pressing the PRE +/- key anytime in programming will quick take you out of programming mode and back to your last operation net preset. NET GENERAL USE <> TO SELECT ITEM PT SELECT NET TO MODIFY 00 [ARTY ] LOS Fixed Frequency Programming PT SELECT NET TO MODIFY 01 [NET1 ]

26 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation OPERATIONAL MODE RCV SIGNAL STRENGTH METER 04*NET4 LOS R. VOL TYPE R: 030.00000 T: 030.00000 T. VOL FREQUENCY PT ADF JACK MODE NET TYPE NET NUMBER RECEIVE (R) INDICATOR VOLUME METER NORM SQUELCH SETTING MODULATION MODE RECEIVE FREQUENCY TRANSMIT FREQUENCY DATA RATE PT NORM UNSAVED CHANGES FMOFF SQLMODE LOS NONE RATE CIRCULAR ARROW BUTTON (PRESS TO CHANGE DISPLAYS.) DENOTES PLAIN TEXT CIPHER TEXT OPERATION. VOC ADF OFF DATA DATA PORT MODE NET NAME Receive Displays

27 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation OPERATIONAL MODE TRANSMIT POWER OUT METER 04*NET4 LOS T. VOL TYPE R: 030.00000 T: 030.00000 T. VOL FREQUENCY PT ADF JACK MODE NET TYPE NET NUMBER TRANSMIT (T) INDICATOR VOLUME METER NORM SQUELCH SETTING MODULATION MODE RECEIVE FREQUENCY TRANSMIT FREQUENCY DATA RATE PT NORM UNSAVED CHANGES FMOFF SQLMODE LOS NONE RATE CIRCULAR ARROW BUTTON (PRESS TO CHANGE DISPLAYS.) DENOTES PLAIN TEXT CIPHER TEXT OPERATION. VOC ADF OFF DATA DATA PORT MODE NET NAME Transmit Displays

28 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Turn on the radio by rotating the function switch to PT or CT as applicable for your net. Choose CT. Select the desired LOS fixed frequency net by pressing the PRE + or - switch on the KDU. Adjust volume level for comfortable listening level with VOL + or - switch on the KDU. The volume bar graph on the display moves in response to pressing this switch. R. VOLNORM PT 04-NET4 LOS VOC VOC FM TONE TYPE ADF DATA MODE SQL  R. VOLNORM VINSON TEK01 CT 00-ARTY LOS VOC VOC FM TONE TYPE ADF DATA MODE SQL  R. VOLNORM VINSON TEK01 CT R:046.57500 LOS T:046.57500 NONE FREQUENCY RATE  Net Operation

29 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Attempt to make voice communications with another station operating on this net. Press PTT on H-250 handset prior to speaking. Observe on the display that the T/R indicator changes from R to T when pressing the PTT switch. If called station replies, respond back on quality of their transmission. Receive signal strength indicator bar graph changes to transmit power indicator when radio switches from receive to transmit. R. VOLNORM VINSON TEK01 CT 00-ARTY LOS VOC VOC FM TONE TYPE ADF DATA MODE SQL  R. VOLNORM VINSON TEK01 CT R:046.5750 LOS T:046.5750 NONE FREQUENCY RATE  RECEIVE DISPLAYS TRANSMIT DISPLAYS T. VOLNORM VINSON TEK01 CT 00-ARTY LOS VOC VOC FM TONE TYPE ADF DATA MODE SQL  T. VOLNORM VINSON TEK01 CT R:046.5750 LOS T:046.5750 NONE FREQUENCY RATE  Net Operation

30 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Changes can be made to a LOS fixed frequency net without reprogramming the radio. Press the Circular arrow button to get to the frequency display. Press the right arrow key until the receive frequency begins to flash. Press numeral keys in order to set in new frequency. Press [ENT] to set receive frequency and to set the same frequency to transmit. Press [ENT] again. The overridden frequency will remain until the radio is switched to another net. They are lost at this time. R. VOLNORM VINSON TEK01 CT 00-ARTY LOS VOC VOC FM TONE TYPE ADF DATA MODE SQL  R. VOLNORM VINSON TEK01 CT R:046.57500 LOS T:046.57500 NONE FREQUENCY RATE  R. VOLNORM VINSON TEK01 CT R:069.12500 LOS T:069.12500 NONE FREQUENCY RATE   R. VOLNORM VINSON TEK01 CT R:046.57500 LOS T:046.57500 NONE FREQUENCY RATE  Operational Overrides

31 Reconnaissance and Surveillance Leader Course After making a temporary override of any parameter, an asterisk (*) appears on the radio display next to the net number to indicate a modification to a programmed net. Use the SAVE function to save overridden parameter changes to the radio immediately. Press the [OPT] key to access the OPTIONS sub-menu. Use right arrow key to choose SAVE. Press [ENT] to Save overridden parameters to the Net Preset. AUTO SAVE is another feature related to overrides and SAVE. When this is set to ON, SAVE becomes unavailable on the OPTION menu. R. VOLNORM VINSON TEK01 CT 00*ARTY LOS VOC VOC FM TONE TYPE ADF DATA MODE SQL  PT COMSEC POWER RETRANS TIME GPS SAVE USE <> TO SELECT ITEM NORM DAMA SCAN PORTS SECUR CFIG USE <> TO SELECT ITEM AUTO SAVE OVERRIDES? YES Operational Overrides LOS Fixed Frequency Operation

32 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation LOS Fixed Frequency Net Programming

33 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Option Menu allows for changes to operational parameters. Menu items that pertain to LOS FIXED FREQUENCY are: –COMSEC –POWER –SAVE Use COMSEC to change COMSEC mode and or the TEK number selected. Use POWER to change the power level. Use SAVE to make any temporary OVERRIDES permanent. If SAVE is not on this menu, then AUTO SAVE overrides is set to ON in the Programming CFIG menu. Options PT COMSEC POWER RETRANS TIME GPS SAVE USE <> TO SELECT ITEM

34 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Options - Overrides OPT POWER TX POWER LEVEL 1 WATT 1.3 WATTS 1.6 WATTS 2 WATTS 2.5 WATTS 3 WATTS 4 WATTS 5 WATTS 6.3 WATTS 10 WATTS 13 WATTS 16 WATTS 20 WATTS TIMESAVECOMSECGPS CRYPTO MODE NONE VINSON ENCRYPTION KEY TEK 01 - 25 KG-84 FASCINATOR ENCRYPTION KEY TEK 01 - 25 ENCRYPTION KEY* TEK 01 - 25 PT COMSEC POWER RETRANS TIME GPS SAVE USE <> TO SELECT ITEM RETRANS

35 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Options - SAVE OPT POWERTIMESAVECOMSECGPS PT COMSEC POWER RETRANS TIME GPS SAVE USE <> TO SELECT ITEM RETRANS SAVE only appears in OPTIONS menu if the CFIG setting ‘AUTO SAVE OVERRIDES?’ is set to OFF. Used to save any overrides made to the currently used operating Net Preset.

36 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Options - TIME OPT POWERTIMESAVECOMSECGPS PT COMSEC POWER RETRANS TIME GPS SAVE USE <> TO SELECT ITEM RETRANS GPS_SYNCUSER_ENTRY TIME OF DAY DD/MM/YYYY HH:MM:SS TIME –GTOD - SINCGARS –TOD - HAVE QUICK –HPW TOD - HPW SATCOM HPWSINCGARS HAVE_QUICK

37 Reconnaissance and Surveillance Leader Course LOS Fixed Frequency Operation Options - GPS OPT POWERTIMESAVECOMSECGPS PT COMSEC POWER RETRANS TIME GPS SAVE USE <> TO SELECT ITEM RETRANS NAVIGATE HDG: 147.5° ALT: 191m VEL: 110 knots  05 SATS 24/09/99 12:34:56 NAVIGATE LAT: 43’ 08.8260N LNG: 77’ 33.4160W  05 SATS 24/09/99 12:34:56  External GPS unit must be connected to GPS connector J2 turned on and able to get a position fix. Metric, English or Nautical Units as programmed in the PLGR Displays coordinate system as programmed in the PLGR


Download ppt "Reconnaissance and Surveillance Leader Course MODULE 4 AN/PRC-117F LOS FIXED FREQUENCY OPERATION."