PHOENICS Pressure Drop in 90 0 Bend. Introduction This presentation outlines the modeling of the pressure drop in a 90 0 bend for a range of configurations.

Similar presentations


Presentation on theme: "PHOENICS Pressure Drop in 90 0 Bend. Introduction This presentation outlines the modeling of the pressure drop in a 90 0 bend for a range of configurations."— Presentation transcript:

1 PHOENICS Pressure Drop in 90 0 Bend

2 Introduction This presentation outlines the modeling of the pressure drop in a 90 0 bend for a range of configurations. The objective being to illustrate how PHOENICS can provide valuable data on alternative designs, BEFORE any material is cut.

3 The Geometry An approximation of the current Walker Filtration inlet design in the PHOENICS VR viewer. Inlet Flow into filter unit Air Passage The inlet has a diameter of 20mm and is pressurised to 3Bar. The working fluid at the inlet is air at 20 0 C.

4 Results – Example 1 Pressure Drop = 23,353Pa. Large drop due to the poor flow characteristics of the port. Inlet Flow into filter unit

5 Results – Example 2 Pressure Drop = 7,494Pa. The smoother geometry of the port results in a reduced pressure drop. Inlet Flow into filter unit

6 Results – Example 3 Pressure Drop = 14,065Pa. Although still an improvement on Example 1, the introduction of the vane has increased the pressure drop when compared to Example 2. This is probably due to the reduction in swept volume of the port due to the presence of the vane. The position and profile of the vane(s) will also influence the flow rate, together with its effect on turbulence. Inlet Flow into filter unit

7 Results – Example 4 Pressure Drop = 7,558Pa. An attempt has been made to compensate for the presence of the vane by increasing the port size. This has improved the pressure drop and is close to that of Example 2. This suggests that care is needed if the introduction of a turning vane(s) is to have a real benefit. Additional analysis is required to assess the effect on turbulence reduction, number of vanes, vane size, and position. Inlet Flow into filter unit

8 Results – Example 4 Various views of velocity data based on Example 4.

9 END 40 High Street, Wimbledon, London, SW19 5AU Tel: 020 8947 7651 Fax:020 8879 3497 Web: www.cham.co.ukwww.cham.co.uk E-mail: sales@cham.co.uk