Presentation is loading. Please wait.

Presentation is loading. Please wait.

“Frequency domain” EM“Time domain” EM. Measurement of signal decay – sample the decaying amplitudes in a number of time windows, or “channels” As the.

Similar presentations


Presentation on theme: "“Frequency domain” EM“Time domain” EM. Measurement of signal decay – sample the decaying amplitudes in a number of time windows, or “channels” As the."— Presentation transcript:

1 “Frequency domain” EM“Time domain” EM

2 Measurement of signal decay – sample the decaying amplitudes in a number of time windows, or “channels” As the receiver is moved over the target, the response of each channel is recorded separately

3 “Time domain” EM example graphitic black shale is very conductive response persists to very late channels (good conductor) asymmetry changes early channels have a maximum to the right late channels have a maximum to the left

4 EM methods: General comments Major advantages Quick and efficient (relative to resistivity/IP) Good depth penetration (up to 1000 m for time domain EM, but perhaps 50 m for airborne systems) Tunable for specific targets (coil orientation, separation, frequencies, etc) Interpretation charts can yield the conductivity-thickness product) Detailed modelling and interpretation possible

5 EM methods: General comments Disadvantages Requires connected conductive targets Conductive overburden drastically reduces penetration Some conductor geometries are invisible – may require more than one coil orientation/configuration to detect

6 EM case studies in exploration and engineering

7 VLF systems Primary field, P is horizontal where a conductor is present this changes (“tilts”) the total field (P + S) tilt angle survey will “crossover” over a conductor Facing the transmitterSchematic view

8 VLF from Atlantic Nickel, New Brunswick a) Profiles

9 VLF from Atlantic Nickel, New Brunswick b) Contours C 23 = (t 3 +t 4 ). – (t 1 +t 2 ) (designed to transform crossovers into positive peaks, and smooth noise)

10 HLEM profiles from Woburn, Quebec Note absence of a signature from disseminated sulfides Characteristic curves used to extract the following information: Dip ~ 60 o

11 Use of characteristic curves

12 Student exercise: Given the profile on the right, and the characteristic curves above, estimate: i) The depth to the conductor edge, and ii) The conductivity-thickness product for the conductor. Survey parameters: Source-receiver spacing 61 m Frequency 800 Hz Magnetic permeability 4  x 10 -7 N.A -2 (Units should cancel, but perhaps you need to check …)

13 Quadrature AEM in the Canadian Shield Note the low separation between in-phase and out-of- phase response, indicating an intermediate conductor, response parameter ~ 1.5

14 Quadrature AEM in the Canadian Shield Note rather poor agreement between various methods – the sulphide deposits appear on the mag survey, but the large negative peak remains unexplained.

15 Airborne EM, northern Sweden Contour map of real component anomalies, Skellefta orefield Notes: Mean ground clearance 30 m, operating frequency 3.5 kHz Contours are in ppm of primary field Anomaly belts to the SW correspond to graphitic shales Belt just to the north of these is due to sulphide ore, but partly obscured by power cable Northern part of the area contains 3 distinct anomaly centers, all correspond to strong sulphide mineralization

16 HLEM and resistivity, aquifer, western Africa Conductive weathered layer obscures fractured quartzite aquifer Only one of the three anomalies is visible on DC resistivity Anomaly C was drilled, aquifer encountered at 30 m depth

17 HLEM, environmental survey The extent of the waste dump is clearly indicated by the minimum on all curves The high conductivity clays shift the curves at different frequencies

18 Time domain EM, Brazil Thickness, conductivity of the weathered layer is influenced by rock type Mafic volcanics are visible in all six channels Greywacke is only apparent on channels 1-4

19 Ground conductivity over a contaminant plume, Portugal Groundwater contamination is mapped using a vertical loop Geonics EM-34 Intercoil spacing was 20 m, contamination plume is observed extending to the west – conductivity is more than 300% of background values

20 Mapping soil salinity Vertical loop, 3.7 m coil spacing 16 lines, spaced at 50 m intervals, stations every 5.5 m Low apparent conductivity indicates unsalinized soils, but conductivity highs indicate extreme salinity.

21 Mapping clay and glacial scour

22 Images from Ford, Keating and Thomas (2007) – see course web pages Small aircraft fitted with magnetometer in rear stinger (Sander Geophysics) de Haveilland Dash 7 fitted with MEGATEM EM system (Fugro)

23 Images from Ford, Keating and Thomas (2007) – see course web pages Schematic of time- domain airborne EM system

24 Images from Ford, Keating and Thomas (2007) – see course web pages