1 Copyright © 2012 Lippincott Williams & Wilkins. Unauthorized commercial reproduction of this slide is prohibited Supplemental PowerPoint Slides Biomechanical risk factors for proximal junctional kyphosis: a detailed numerical analysis of surgical instrumentation variables Marco Cammarata, BEng 1,2, Carl-Éric Aubin, PhD, PEng 1,3, Xiaoyu Wang, PhD 1,3, Jean-Marc Mac-Thiong, MD, PhD 2,3 1. Department of Mechanical Engineering, École Polytechnique de Montréal, Canada 2. Research Center, Hôpital du Sacré-Cœur de Montréal, Canada 3. Research Center, Sainte-Justine University Hospital Center, Canada

2 Copyright © 2012 Lippincott Williams & Wilkins. Unauthorized commercial reproduction of this slide is prohibited Supplemental PowerPoint Slides 1/3 A total of 576 numerical simulations and a sensitivity analysis were performed for six adult spinal deformity instrumentation cases to assess four biomechanical indices related to the development of PJK: –Immediate postoperative proximal junctional kyphotic angle; –Thoracic kyphosis; –Proximal junctional intervertebral flexion forces; –Proximal junctional intervertebral flexion moment; The individual effect of four instrumentation variables on each of the above indices was evaluated: –Proximal dissection procedure; –Implant type at the upper instrumented vertebra; –Sagittal thoracic rod curvature; –Proximal diameter of the proximal transition rod;

3 Copyright © 2012 Lippincott Williams & Wilkins. Unauthorized commercial reproduction of this slide is prohibited Supplemental PowerPoint Slides 2/3 Each of the followings biomechanically helps reducing the risk of PJK: –Preserving more intervertebral elements at the proximal end of the instrumentation; –Using transverse process hooks instead of pedicle screws at the upper instrumented vertebra; –Using tapered transition rods at the proximal end of the instrumentation. Monoaxial and multiaxial screws at upper instrumented vertebra had similar effects on the four biomechanical indices. Resulting average, minimum, and maximum values of each biomechanical index (PJ: proximal junctional; TK: thoracic kyphosis; UIV: upper instrumented vertebra)

4 Copyright © 2012 Lippincott Williams & Wilkins. Unauthorized commercial reproduction of this slide is prohibited Supplemental PowerPoint Slides 3/3 Typical results for one case (#2): FSU: intact functional spinal unit; BCF: bilateral complete facetectomy; PLD: posterior ligaments dissection; FAS: fixed angle screw; MAS: multiaxial screw; TPH: transverse process hook; PJ: proximal junctional; UIV: upper instrumented vertebra.


Download ppt "Copyright © 2012 Lippincott Williams & Wilkins. Unauthorized commercial reproduction of this slide is prohibited Supplemental PowerPoint Slides Biomechanical."