Presentation is loading. Please wait.

Presentation is loading. Please wait.

EN46001 llc. llc Horizon Medical Technologies' mission is to distribute quality products that are cost effective and unique to the biomedical and healthcare.

Similar presentations


Presentation on theme: "EN46001 llc. llc Horizon Medical Technologies' mission is to distribute quality products that are cost effective and unique to the biomedical and healthcare."— Presentation transcript:

1 EN46001 llc

2 llc Horizon Medical Technologies' mission is to distribute quality products that are cost effective and unique to the biomedical and healthcare industry worldwide.

3 llc Horizon Medical Technologies has been involved with the health care industry for the past 11 years providing risk reduction solutions to both long term care groups as well as acute care facilities. We have, hands down, the most effective and cost contained drug testing program on the market today. In every instance, health care groups have saved an average of 40% on their previous method of testing with labs while maintaining the highest level of integrity with their drug testing methodologies. llc

4 llc 1.Amphetamine 2.Barbiturate 3.Benzodiazepine 4.Cocaine 5.Marijuana 6.Methadone 7.Methamphetamine 8.Morphine 9.Phencyclidine 10.Tricyclids 11.Propoxyphene 12.Ecstasy

5 llc 1.Collect the donors Specimen 2.Label the test panel with donor ID & date 3.Specimens may be kept at room temperature (59-86 o F) up to 24 hours, refrigerated up to 7 days, or frozen up to 2 years 4.If the specimen is frozen or refrigerated equilibrate to room temperature prior to testing 1.Collect the donors Specimen 2.Label the test panel with donor ID & date 3.Specimens may be kept at room temperature (59-86 o F) up to 24 hours, refrigerated up to 7 days, or frozen up to 2 years 4.If the specimen is frozen or refrigerated equilibrate to room temperature prior to testing Performing the test

6 llc Performing the test  Next, open the foil pouch at the notch and remove the testing device. Do not open the sealed pouch unless ready to perform the test.

7 llc  Holding the device vertically, insert the testing device in the specimen for 10 to 15 seconds.  Make sure to keep the specimen surface below the area indicated on the device. Performing the test

8 llc Remove the device from the specimen and place it on a flat, dry surface.  Remove the device from the specimen and place it on a flat, dry surface. Performing the test

9 llc Alternate Method of Testing  Helpful when the donor provides a minimal specimen volume.  The specimen can be added to the device using the supplied pipette.  Press the bulb to fill the pipette with the sample collection. Performing the test

10 llc A lternate Method of Testing  H H H Holding the dropper vertically, add 10-12 drops of the specimen into the sample well. Performing the test

11 llc Interpreting the Results - Negative  Read between 4 to 7 minutes  DO NOT read after 7 minutes  Negative if: “Control” line & “Test” line regions both appear  Read between 4 to 7 minutes  DO NOT read after 7 minutes  Negative if: “Control” line & “Test” line regions both appear

12 llc Interpreting the Results-Positive  Positive if: absence of a line in any “Test” line region.  Samples with positive results should be confirmed at our laboratory through GC/MS technology  Positive if: absence of a line in any “Test” line region.  Samples with positive results should be confirmed at our laboratory through GC/MS technology

13 llc Interpreting the Results-Invalid  Invalid if: no “Control” line develops within 5 minutes  Repeat the assay with a new test device if this occurs.  Invalid if: no “Control” line develops within 5 minutes  Repeat the assay with a new test device if this occurs.

14 llc Products include: Amphetamine Methadone Barbiturates Methamphetamine Benzodiazepine Morphine Cocaine PCP (Phencyclidine) Marijuana TCA (Tricyclic Antidepressants) Ecstasy Propoxyphene Products include: Amphetamine Methadone Barbiturates Methamphetamine Benzodiazepine Morphine Cocaine PCP (Phencyclidine) Marijuana TCA (Tricyclic Antidepressants) Ecstasy Propoxyphene INSTANT-VIEW™ tests are intended to detect drugs of abuse in human urine at specified cutoff levels.

15 llc Benefits  FDA approved on ten rapid DOA tests  Available in a variety of formats  Cassette  Dip strip  Multi-panel  Panel devices can be custom configured  Multi-drug screen can test up to 10 drugs at one time  Built-in urine adulteration identification test Benefits  FDA approved on ten rapid DOA tests  Available in a variety of formats  Cassette  Dip strip  Multi-panel  Panel devices can be custom configured  Multi-drug screen can test up to 10 drugs at one time  Built-in urine adulteration identification test

16 llc Benefits  One-step procedure  Easy to use with no professional training  Tests stable for 2 years at room temperature  SAMHSA defined cut-off levels  Multi drug screen devices can be used as either a dip and read or with the transfer pipette method Benefits  One-step procedure  Easy to use with no professional training  Tests stable for 2 years at room temperature  SAMHSA defined cut-off levels  Multi drug screen devices can be used as either a dip and read or with the transfer pipette method

17 llc  Website: www.HorizonMedTech.com www.HorizonMedTech.com  E-mail: info@HorizonMedTech.com info@HorizonMedTech.com Contact & Ordering Information Click these hyperlinks to get more information. 904 Bishop Drive, Morgantown, WV 26505 Toll Free: 1-800-296-0482 (Within U.S.A.) Phone: 304-296-1182 Fax: 304-296-1186 904 Bishop Drive, Morgantown, WV 26505 Toll Free: 1-800-296-0482 (Within U.S.A.) Phone: 304-296-1182 Fax: 304-296-1186

18 EN46001


Download ppt "EN46001 llc. llc Horizon Medical Technologies' mission is to distribute quality products that are cost effective and unique to the biomedical and healthcare."

Similar presentations


Ads by Google