1 Fluorescence from Air in Showers (FLASH) J. Belz 1, Z. Cao 2, P. Chen 3*, C. Field 3, P. Huentemeyer 2, W-Y. P. Hwang 4, R. Iverson 3, C.C.H. Jui 2, T. Kamae 3, G.-L. Lin 4, E.C. Loh 2, K. Martens 2, J.N. Matthews 2, W.R. Nelson 3, J.S.T. Ng 3, A. Odian 3, K. Reil 3, J.D. Smith 2, P. Sokolsky 2*, R.W. Springer 2, S.B. Thomas 2, G.B. Thomson 5, D. Walz 3 1 University of Montana, Missoula, Montana 2 University of Utah, Salt Lake City, Utah 3 Stanford Linear Accelerator Center, Stanford University, CA 4 Center for Cosmology and Particle Astrophysics (CosPA), Taiwan 5 Rutgers University, Piscataway, New Jersey * Collaboration Spokespersons SLAC E-165

2 MEASURING FLUORESCENCE AT SLAC Extensive Air Showers (EAS) are predominantly a superposition of electro- magnetic (e+, e-, gamma) sub-showers. Important N 2 transition (2P) not accessible by proton excitation; only e-beam can do it. Final Focus Test Beam (FFTB) beam-line provides energy equivalent showers from ~10 15 to ~10 20 eV. –10 8 -10 10 electrons/pulse at 28.5 GeV.

3 The SLAC Accelerator: 3 km long with a klystron approx every 13 m. Delivers up to 50 GeV of e - or e +. The SLAC LINAC Beam Switchyard: T461 located in the FFTB

4 Two Mile Accelerator

5 The FFTB A 28.5 GeV e - beam is delivered to the FFTB. At the final focus beam cross section is 1  m wide and < 0.1  m high. At T461 location beam is mm scale. Pulse length is pico-second scale. Energy spread is 0.1%. Repetition rate is 10 Hz (occasionally 1 Hz and 30 Hz).

6 OBJECTIVES Spectrally resolved measurement of fluorescence yield to better than 10%. Investigate effects of electron energy. Study effects of atmospheric impurities. Observe showering of electron pulses in air equivalent substance (Al 2 O 3 ) with energy equivalents around 10 18 eV.

7 PROGRAM Gas Composition –N 2 /O 2 dependence, and Ar, CO 2, H 2 O impurities Pressure Dependence –Yield versus Pressure down to 10 torr Energy Dependence –Yield versus electron energy distribution down to 100keV Fluorescence Spectrum –Resolve individual bands using narrow band filters or spectrometer. Pulse Width –Pressure dependence of fluorescence decay time for each spectral band

8 SYSTEMATIC ERROR BUDGET 9.2%7%Total 6.5%4%Optical System 5.4% Detector System 3%-Showering 2.2%2%Beam Thick TargetThin Target

9 THIN TARGET EXPERIMENT Thin target stage requires the 28.5 GeV beam to deliver 10 8 -10 9 e - per pulse. –Pressure variations –Fluorescence Spectrum –Linearity of fluorescence with beam charge. –Impurities.

10 THIN TARGET AIR CHAMBER LEDs PMTs

11 THICK TARGET EXPERIMENT Thick target stage requires the 28.5 GeV beam to deliver 10 7 -10 8 e - per pulse. The layers of Al 2 O 3 must be remotely moveable to allow changing of shower depth observed. –Shower depth variations. –N 2 /O 2 variations. –Fluorescence spectrum.

12 THICK TARGET SETUP

13 Test Run (T461) in June 2002 J. Belz 1, Z. Cao 2, P. Chen 3*, C. Field 3, P. Huentemeyer 2, W-Y. P. Hwang 4, R. Iverson 3, C.C.H. Jui 2, T. Kamae 3, G.-L. Lin 4, E.C. Loh 2, K. Martens 2, J.N. Matthews 2, W.R. Nelson 3, J.S.T. Ng 3, A. Odian 3, K. Reil 3, J.D. Smith 2, P. Sokolsky 2*, R.W. Springer 2, S.B. Thomas 2, G.B. Thomson 5, D. Walz 3 1 University of Montana, Missoula, Montana 2 University of Utah, Salt Lake City, Utah 3 Stanford Linear Accelerator Center, Stanford University, CA 4 Center for Cosmology and Particle Astrophysics (CosPA), Taiwan 5 Rutgers University, Piscataway, New Jersey

14 Thin Target Chamber Constructed in 2002

15 LED PMT Test Run Equipment: Thin Target Chamber, 2 PMT’s with calibration pulsed LED, wide-band filter, digital scope for pulse-shape recording.

16 My Summer Vacation two weeks of data taking over three weeks in June 2002 (3 days at Monterey Bay, 2 in SF!) 707 “runs” each with between 2500 to 5000 recorded ‘events’:  2 million recorded ‘events’ gas fillings: air, nitrogen, air-nitrogen mixtures, ethylene pressures between 3 and 760 torr readout from two PMTs ran in “parasitic” mode: we get whatever beam characteristics the primary user wants

17 Surprise ! Observed an unexpected non- linear enhancement in the PMT signal. Non-linearity was seen in both air and nitrogen

18 Effect was enhanced at low pressures and was reduced near sea-level pressure

19 What’s Going on? Nobody knows…it’s a “New” result! This is where it gets to be “FUN!” (Definition: Physics…kinda like “fun”…only different) Let’s take a simplistic look at what’s happening with the beam: –Each pulse is ~ 1mm in size (the focusing magnets were off…else it would be focused down to ~1  m in the transverse dimension)

20 I get to play (bad) “phenomenologist” –Beam pulse passes in ~ 3 picoseconds –Treat pulse as a uniform ball of charge and estimate impulse Δp it imparts on an electron (and hence the kinetic energy gained ΔE K : Δp ~ Ne 2 /4  0 r 2 ּ Δt (r ~ 1 mm) ΔE K =(Δp) 2 /2m ~ 700 eV for N=10 10 IF the “ejected” electron does not suffer collisions while being accelerated…this is enough energy to cause “secondary ionization” Important quantity here is the “Mean Free Path” λ.

21 Mean Free Path The value of should depend (inversely) on: –cross sectional area of the molecule (~1/πR 2 unit: m -2 ) –density of molecules (~ 1/n: unit: m 3 ) From dimensional analysis: expect λ ~ 1/(n πR 2 ) “exact” calculation gives λ = 1/(1.404n πR 2 ) for point-particle - molecule collisions (replace R by D for molecule-molecule)

22 Mean Free Path At room temperature in air/nitrogen, we have λ = 2x10 -4 /P λ in meter, P in torr

23 Mean Energy Gained (before collision) Estimate the energy gained by an electron before collision: ΔE K ~ Ne 2 /4  0 × [ 1/r - 1/(r+λ) ]

24 CAVEAT EMPTOR Seems like we can understand the non- linearity from a very simplistic model PRBLEM: it is TOO simplistic…we have neglected the enormous magnetic field carried by the beam pulse…the combination leads to “plasma excitations”…better leave it for the “real” theorists (who are now salivating over this result)

25 Whew... Fortunately the non- linearity went away when the beam charge was reduced to below ~ 1x10 9 electrons/pulse My vacation was saved!!!

26 Preliminary Result

27 Uncertainties: Air (incomplete!)

28 How does this compare with earlier measurements? Kakimoto et.al, Nucl. Inst. And Meth. A372 527 (1996) Preliminary result from this test run @ 28.5 GeV: 5-6 photons per m per e -

29 But... This is rather amazing…it looks as if for most of the lower atmosphere (up to 15km) the fluorescence yield (in air) is roughly independent of pressure!!!!! But the density of molecules is proportional to pressure… What is going on?

30 Collisional De-excitation It appears that collisions can also de-excite molecules (in addition to “emission”) From the result…oxygen is very effective at de-exciting…addition of 21% oxygen to nitrogen decreases yield by a factor ~8 at near sea level pressure Key quantity is “mean” time between collisions τ

31 Mean Collision Time τ Expect τ ~ λ/v mean For an ideal gas: v mean ~ (3kT/m) 1/2 Nitrogen at room temperature v mean ~ = 450 m/s Compare to mean emission time of ~50 ns

32 N 2 Decay Time Measurement

33

34

35 N 2 (in air) Decay Time Measurement

36 N 2 Decay Time Measurement

37

38 Summary Don’t forget U. of Utah holds the World’s Record for the highest energy particle ever seen Always question “how do we know this?”…most of the time you end up learning about how measurements are made FLASH experiment had a very successful test run and made an unexpected discovery Many aspects of these results can be explained by simple kinetic theory.

39 Undergrad and Highschool Students Who Worked on FLASH Undergrads: –Ben Jones –Ryan Snow –Gary Burt –Cigdem Ozkan Highschool: –Melissa Maestas –Justin Findlay –Jason Thomas