Alfonso Mantero, INFN Genova Models for the Simulation of X-Ray Fluorescence and PIXE A. Mantero, S. Saliceti, B. Mascialino, Maria Grazia Pia INFN Genova,

Similar presentations


Presentation on theme: "Alfonso Mantero, INFN Genova Models for the Simulation of X-Ray Fluorescence and PIXE A. Mantero, S. Saliceti, B. Mascialino, Maria Grazia Pia INFN Genova,"— Presentation transcript:

1 Alfonso Mantero, INFN Genova Models for the Simulation of X-Ray Fluorescence and PIXE A. Mantero, S. Saliceti, B. Mascialino, Maria Grazia Pia INFN Genova, Italy http://www.ge.infn.it/geant4/lowE/index.html NSS, Rome, 21 October 2004

2 Alfonso Mantero, INFN Genova Courtesy ESA Space Environment & Effects Analysis Section X-Ray Surveys of Asteroids and Moons Induced X-ray line emission: indicator of target composition (~100  m surface layer) Cosmic rays, jovian electrons Geant3.21 ITS3.0, EGS4 Geant4 Solar X-rays, e, p Courtesy SOHO EIT C, N, O line emissions included Fluorescence Emission Original motivation from astrophysics requirements Wide field of applications beyond astrophysics

3 Alfonso Mantero, INFN Genova X-ray fluorescence and Auger effect Calculation of shell cross sections –Based on Livermore (EPDL) Library for photoelectric effect –Based on Livermore (EEDL) Library for electron ionisation –Based on Penelope model for Compton scattering Detailed atom description and calculation of the energy of generated photons/electrons –Based on Livermore EADL Library –Production threshold as in all other Geant4 processes, no photon/electrons generated and local energy deposit if the transition predicts a particle below threshold

4 Alfonso Mantero, INFN Genova Test process Unit, integration and system tests Verification of direct physics results against established references Comparison of simulation results to experimental data from test beams –Pure materials –Complex composite materials Quantitative comparison of simulation/experimental distributions with rigorous statistical methods –Parametric and non-parametric analysis

5 Alfonso Mantero, INFN Genova Verification: X-ray fluorescence Transition Probability Energy (eV) K L2 1.01391 -1 6349.85 K L3 1.98621 -1 6362.71 K M2 1.22111 -2 7015.36 K M3 2.40042 -2 7016.95 L2 M1 4.03768 -3 632.540 L2 M4 1.40199 -3 720.640 L3 M1 3.75953 -3 619.680 L3 M5 1.28521 -3 707.950 K  transition K  transition Transitions (Fe) Comparison of monocromatic photon lines generated by Geant4 Atomic Relaxation w.r.t. reference tables (NIST)

6 Alfonso Mantero, INFN Genova Verification: Auger effect Auger electron lines from various materials w.r.t. published experimental results 366.25 eV (367) 428.75, 429.75 eV (430 unresolved) 436.75, 437.75 eV (437 unresolved) Precision: 0.74 % ± 0.07 Cu Auger spectrum

7 Alfonso Mantero, INFN Genova Test beam at Bessy Advanced Concepts and Science Payloads A. Owens, A. Peacock Si GaAs FCM beamline Si reference XRF chamber Complex geological materials Hawaiian basalt Icelandic basalt Anorthosite Dolerite Gabbro Hematite

8 Alfonso Mantero, INFN Genova Comparison with experimental data statistically compatible 95% C.L. Experimental and simulated X-ray spectra are statistically compatible at 95% C.L. Ac (95%) = 0.752 Anderson Darling test Beam Energy 4.9 6.5 8.2 9.5 A2 0.04 0.01 0.21 0.41 Effects of detector response function + presence of trace elements Pearson correlation analysis: r>0.93 p<0.0001

9 Alfonso Mantero, INFN Genova PIXE Calculation of cross sections for shell ionization induced by protons or ions Two models available in Geant4: –Theoretical model by Grizsinsky – intrinsically inadequate –Data-driven model, based on evaluated data library by Paul & Sacher (compilation of experimental data complemented by calculations from EPCSSR model by Brandt & Lapicki) Generation of X-ray spectrum based on EADL –Uses the common de-excitation package

10 Alfonso Mantero, INFN Genova PIXE – Cross section model Fit to Paul & Sacher data library; results of the fit are used to predict the value of a cross section at a given proton energy –allow extrapolations to lower/higher E than data compilation First iteration, Geant4 6.2 (June 2004) –The best fit is with three parametric functions for different groups of elements –6 ≤ Z ≤ 25 –26 ≤ Z ≤ 65 –66 ≤ Z ≤ 99 Second iteration, Geant4 7.0 (December 2004) –Refined grouping of elements and parametric functions, to improve the model at low energies Next: protons, L shell ions, K shell

11 Alfonso Mantero, INFN Genova Quality of the PIXE model How good is the regression model adopted w.r.t. the data library? Goodness of model verified with analysis of residuals and of regression deviation –Multiple regression index R 2 –ANOVA –Fisher’s test Results (from a set of elements covering the periodic table) –1 st version (Geant4 6.2): average R 2 99.8 –2 nd version (Geant4 7.0): average R 2 improved to 99.9 at low energies –p-value from test on the F statistics < 0.001 in all cases Residual deviation Total deviation Regression deviation Test statistics Fisher distribution

12 Alfonso Mantero, INFN Genova Bepi Colombo Mission to Mercury Study of the elemental composition of Mercury by means of X-ray fluorescence and PIXE Insight into the formation of the Solar System (discrimination among various models)

13 Alfonso Mantero, INFN Genova A Library For Simulated X-Ray Emission form Planetry Surfaces A. Mantero, S. Saliceti, B. Mascialino, Maria Grazia Pia INFN Genova, Italy A.Owens, ESA NSS, Rome, 21 October 2004

14 Alfonso Mantero, INFN Genova The BepiColombo Mission to Mercury Composed of 2 orbiters carrying a total of 25 scientific experiments: ● Magnetic Field Study ● Planet Surface Mapping ● Planet Surface Composition study ● 4 spectrometer (IR, X, , n) ● 1 laser altimeter HERMES Is an X-Ray spectrometer to measure the composition of the upper layers of planetary surface

15 Alfonso Mantero, INFN Genova X-Ray Detectors Gas Detectors Poor resolution - “< 1KeV @ 5.95 KeV” Poor efficiency at low energies Only for some elements K  lines can be detected ( Mg, Al, Si, S, Ca, Ti, and Fe) Solid State Detectors Better Resolution - 140 eV @ 5.89 KeV” Greater Efficiency at low Energies Faster count speed Basalt fluorescence spectrum Beam Energy 9.5 KeV Counts Energy (KeV)

16 Alfonso Mantero, INFN Genova Rocks X-Ray Emission Library ● Space missions are risky, so solid strategies for risk mitigation are to be undertaken ● HERMES is an X-Ray spectrometer studying Mercury's surface composition ● Solid state detector have a better definition than “normal” gas-filled proportional counters ● We will measure detailed X-Ray spectra leading to detailed elemental composition of the crust of the planet ● Space missions are risky, so solid strategies for risk mitigation are to be undertaken ● HERMES is an X-Ray spectrometer studying Mercury's surface composition ● Solid state detector have a better definition than “normal” gas-filled proportional counters ● We will measure detailed X-Ray spectra leading to detailed elemental composition of the crust of the planet We need to study possible responses of the instruments before they are in flight with a very good precision for all the possible situations they can find

17 Alfonso Mantero, INFN Genova Rocks X-Ray Emission Library Test beams at BESSY labs have been undertaken in order to provide a set of X-Ray spectra from PSSL rocks that could be found rocky planets (Mars, Venus, Mercury) Si GaAs FCM beamline Si reference XRF chamber A total of 8 rocks have been irradiated and by now 5 of them have been simulated. Basalt (Hawaii, Madagascar and Iceland) Anorthosite Ematite Gabbro Dolerite (Whin Sill, Java) Obsidian

18 Alfonso Mantero, INFN Genova Rocks Spectra Simulation Geant4 provides advanced instruments for the description of geometry and materials Thanks to a Geant4 simulation we can simulate any rock of known composition with a high degree of confidence

19 Alfonso Mantero, INFN Genova Rocks Spectra Simulation

20 Alfonso Mantero, INFN Genova Summary Geant4 provides precise models for detailed processes at the level of atomic substructure (shells) X-ray fluorescenceAuger electronPIXE X-ray fluorescence, Auger electron emission and PIXE are accurately simulated quantitative statistical analysis Rigorous test process and quantitative statistical analysis for software and physics validation have been performed A new generation of X-Ray detectors will be used shortly for planetary investigations, giving precise results library of rocks X-Ray spectra A library of rocks X-Ray spectra is needed for accurate physic reach and risk mitigation studies generatingany rock of known composition Geant4 is capable of generating X-Ray spectra for any rock of known composition and a library is under production.


Download ppt "Alfonso Mantero, INFN Genova Models for the Simulation of X-Ray Fluorescence and PIXE A. Mantero, S. Saliceti, B. Mascialino, Maria Grazia Pia INFN Genova,"