Presentation is loading. Please wait.

Presentation is loading. Please wait.

Verigy V93000 Service Training

Similar presentations


Presentation on theme: "Verigy V93000 Service Training"— Presentation transcript:

1 Verigy V93000 Service Training
Compact Test Head Verigy-TM Revision Date Changes __ By________ Rev First Version Uli Bahlinger

2 Compact Test Head Manufacturing Manipulator
Flat Panel Holder E6979LF Manipulator E6979LC DUT-Interface with Hard Docking E8009L LINUX Controller Compact Test Head E8014A Compact Test Head

3 Compact Test Head Engineering Manipulator
DUT-Interface without Hard Docking E8009LD Compact Test Head E8014A Engineering Manipulator E6979EC Compact Test Head

4 Power Subsystem Overview Block Diagram (CTH)
Power Subsystem Key Components Compact Test Head From Mains Power V AC Power Backplane AC DC Control Primary Power Box , AC Dist Box V AC DC output to each card slot DC/DC Power Unit AC/DC Power Unit 355V DC Trim DC out Voltage Rack Interface Board Monitor Temp. DC Sense Power Control Bd Power Control DIS Temp. Sensors DIS This block diagram shows the functional blocks and the main connections of the power subsystem. Most parts are in the compact test head. The On/Off unit is external. Pressure Sensor To Controller (RS232) Cooling Unit ON/OFF Unit Compact Test Head

5 Primary Power Distribution CTH Star 400V/230V
Compact Test Head

6 Primary Power Distribution CTH Delta 200V-208V
Compact Test Head

7 Compact Test Head Power Connections
Main breaker Mains power inlet Mains power out (Cal Robot) Compact Test Head

8 Compact Test Head Connections
Low Level Diagnostic Cable RS232 ON/OFF Unit cable Optical link Cooler Control Compressed air Main breaker Mains power inlet Cooling water in Mains power out (Cal Robot) Cooling water out Compact Test Head

9 Connecting Mains Power 1
Remove main breaker cover 1. Release three screws 2. Lift off cover Compact Test Head

10 Connecting Mains Power 2
Remove cable clamp cover 1. Remove four screws 2. Lift off cover 3. Select cover according to cable diameter Compact Test Head

11 Mains Power Terminals Phase L3 terminals L2 L1 N terminal
(Star config. only) PE terminal Compact Test Head

12 Main Breaker Settings Current Selector Instantaneous trip multiple
Star 400V 50A Delta 208V 55A Delta 200V 60A All configurations: 6 Compact Test Head

13 Compact Test Head Bottom/Maintenance Side
AC/DC Power Box On/Off Unit Rack Interface Board Passive Control Board CC2 AC/DC Power Units Jumper Board Active Control Board CC 1 Optical link Compact Test Head

14 Compact Test Head DUT-Side (DUT-Interface and Covers removed)
Power Backplane Front Plane CC2 Power Control Board 12 Power Control Cable 2 Front Plane CC1 Power Control Board 11 Power Control Cable 1 Compact Test Head

15 AC/DC Power Unit – Exchange
Use the hose extraction tool for the cooling hoses Weight : 15kg Compact Test Head

16 Power Subsystem Rack Interface - Location
Residual charge warning LEDs Water cooled heat sink Thermal (Bimetal) switch with release button Accessible from the back side of the CTH In case of problems, always check the “release button” on the temperature switch (bimetal switch) Locating pin Prototype Connectors to Power Backplane Rack Interface State Machine and error latches DIS Controller and CAN bus interface Fan Compact Test Head

17 Hard Docking Interface
The Hard Docking interface must be removed for the exchange of: DUT Interface / Wiring Board Power Control Boards Frontplanes Power Backplane DC/DC Fuses Compact Test Head

18 Space for Pogo Cable Assys
DUT-Interface Wiring Board Utility adapter board Space for Pogo Cable Assys DPS cables To remove the DUT Interface: remove cards from card cages disconnect soft docking air tubes remove 12 countersink screws two persons are needed! Compact Test Head

19 Breakers and Fuses Exchanging a DC/DC fuse Exchanging a breaker
Exchanging an AC fuse Compact Test Head

20 RS232 for low level diagnostic
Power Backplane Cooler Control RS232 for low level diagnostic ON/OFF Unit with EMO Rack Interface Board Connectors AC/DC Power Unit Connectors Compact Test Head

21 Power Backplane LEDs Remove cover to check LEDs Compact Test Head

22 Power Backplane Exchange
1. Remove covers 2. Remove PE wires 3. Remove connectors 4. Remove stiffener rails 5. Disconnect cables 6. Lift off Power Backplane Compact Test Head

23 Control Cable for CAN Bus
Frontplane Connections 355V DC Power In Control Cable for CAN Bus J7 MCLK Output to J nd Clock Board J MCLK Input from J nd Clock Board J DC-Force J DC-Sense J18 GND-Sense Note: Power Contol board of CC2 is removed J9, J8 (not used for CTH) Compact Test Head

24 RS232 and CAN Bus System To Manipulator CTH System controller Rack
interface board Power control board Clock RS232 cable Power control board board Control Cable 2 Control Cable 1 Active control board Card Cage 2 Card Cage 1 To Manipulator Wiring Board Termination This picture shows the routing of the CAN bus, shown from the frontplane side. The arrow points towards the manipulator. The CAN bus starts on the rack interface board and is terminated on the power backplane. It connects all 4 DIS controllers on: 1 rack interface board, 2 power control boards and 1 active control board For Linux controllers a USB to RS232 converter is used for the diagnostic cable. Power backplane CTH Compact Test Head

25 Changes with Compact Test Head
STH and LTH 1 Card Cage for 1 Group Why 2 terms for the same? Filling starts with slot 101 PinScale filling with gaps Slot - Pogo mapping fixed CTH 1 Card Cage for 2 Groups Group # compatible for CTH, STH, LTH Filling starts with slot 105 Filling of cards in pairs Slot - Pogo mapping is flexible and defined by Pogo Mapping file Compact Test Head

26 PinScale 400 fill S1/S2 Pogo locations up to 1024 dig. pins
Compact Test Head Pogo Mapping Pogo location numbers and Group numbers are identical to STH 1 Card Cage for 2 Groups Up to 512 digital pins with PinScale 800 / 3600 at S1 Pogo locations PinScale 400 fill S1/S2 Pogo locations up to 1024 dig. pins Compact Test Head

27 Group 8 for Analog or Digital
PinScale 800/3600 Configuration Group 3 Group 1 Group 2 Group 8 Group 1, 2, 3 for Digital Group 8 for Analog or Digital 317 232 231 230 229 432 429 430 431 228 227 226 225 428 427 426 425 318 319 320 321 322 323 324 301 302 303 304 305 306 307 308 316 315 314 313 312 311 310 309 117 118 119 120 101 104 103 102 105 106 107 108 116 115 114 113 112 111 110 109 121 122 123 124 Group Group 1 Group Group 2 Compact Test Head

28 PinScale 800/3600 Configuration with Analog
1st PS3600 card, slot 1-5, , Pos: 105 Analog 2nd PS3600 card, slot 1-6, , Pos: 106 116 115 112 111 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 3rd PS3600 card, slot 1-7, , Pos: 107 4th PS3600 card, slot 1-8, , Pos: 108 114 113 110 109 5th PS3600 card, slot 2-8, , Pos: 117 6th PS3600 card, slot 2-7, , Pos: 116 117 118 121 122 101 102 7th PS3600 card, slot 2-6, , Pos: 115 1 2 3 4 5 6 7 8 105 106 1 2 3 4 5 6 7 8 8th PS3600 card, slot 2-5, , Pos: 114 119 120 123 124 103 104 107 108 9th PS3600 card, slot 1-1, , Pos: 101 10thPS3600 card, slot 1-2, , Pos: 102 11thPS3600 card, slot 1-3, , Pos: 103 12thPS3600 card, slot 1-4, , Pos: 104 Pos is the physical position in the 1st column of the pogo mapping file ! Compact Test Head

29 PinScale 400 Configuration with Analog
101 102 103 104 5 6 7 8 305 306 307 308 105 106 107 108 1 2 3 4 301 302 303 304 SLOT 1 (SLOT 2) SLOT 3 (SLOT 4) SLOT 5 (SLOT 6) SLOT 7 (SLOT 8) CLOCK DIST / SPMU / UTIL DPS DC PS slot 1,2 DC PS slot 3,4 DC PS slot 5,6 DC PS slot 7,8 TEST HEAD CABLE OUTLET SIDE Group 8 Group 2 Group 1 Group 3 117 118 119 120 121 122 123 124 116 115 114 113 232 231 230 229 228 227 226 225 Cage 1(slot 1-4) Cage 2(slot 5-8) Cage 1(slot 5-8) Cage 2(slot 1-4) 312 311 310 309 316 315 314 313 112 111 110 109 321 322 323 324 317 318 319 320 Cage 1 Cage 2 428 427 426 425 432 431 430 429 This slide describes the relationship between pogo pins on DUT board and card cage in the test head. The compact test head supports 2 card cages. Each cage can contain 8 cards. The relationship between cage number and group number is irrelevant and the system user needs only to use the group number. The cage numbering is used for internal use only. Channel Assignments - The DUT board silk screen shows channel assignment numbers which correspond to the pin group locations. For the digital channels, the pin assignment is defined by the channel and pin number. The analog module is assigned a channel location only, i.e. a high resolution Digitizer located in The I/O assignment for each module is provided in the module description documentation. This test head configuration includes 32 utility lines, up to 2 System PMUs and up to 8 DPS channels. Compact Test Head

30 Group 8 for Analog or Digital
PinScale 400 Configuration Group 2 Group 8 Group 1, 2, 3 for Digital Group 8 for Analog or Digital 232 231 230 229 432 429 430 431 228 227 226 225 428 427 426 425 116 115 114 113 112 111 110 109 117 118 119 120 101 104 103 102 105 106 107 108 121 122 123 124 Group Group 1 Group Group 2 308 317 318 320 321 322 323 324 301 302 303 304 305 306 307 319 316 315 314 313 312 311 310 309 Group 1 Group 3 Compact Test Head

31 PinScale 400 Configuration
with Analog Up to 384 pins, S1 only Group 1 2 3 Card/Cage Filling – Test Head Bottom View 305/306/307/308 321/322/323/324 To Manipulator START 117/118/119/120 317/318/319/320 101/102/103/104 301/302/303/304 Group 2,8 (Cage 2) Analog 313/314/315/316 109/110/111/112 309/310/311/312 Group 1,3 (Cage 1) 121/122/123/124 105/106/107/108 113/114/115/116 317 232 231 230 229 432 429 430 431 228 227 226 225 428 427 426 425 318 319 320 321 322 323 324 301 302 303 304 305 306 307 308 316 315 314 313 312 311 310 309 117 118 119 120 101 104 103 102 105 106 107 108 116 115 114 113 112 111 110 109 121 122 123 124 Group Group 1 Group Group 2 Pogo Filling Compact Test Head

32 PinScale 400 Configuration
with Analog Up to 768 pins, S1 and S2 Group 1 2 3  3  2 1 Card/Cage Filling – Test Head Bottom View 305/306/307/308 321/322/323/324 To Manipulator Continue 117/118/119/120 317/318/319/320 101/102/103/104 301/302/303/304 Group 2,8 (Cage 2) Analog 313/314/315/316 109/110/111/112 309/310/311/312 Group 1,3 (Cage 1) 121/122/123/124 105/106/107/108 113/114/115/116 232 231 230 229 432 429 430 431 228 227 226 225 428 427 426 425 116 115 114 113 112 111 110 109 117 118 119 120 101 104 103 102 105 106 107 108 121 122 123 124 Group Group 1 Group Group 2 308 317 318 320 321 322 323 324 301 302 303 304 305 306 307 319 316 315 314 313 312 311 310 309 Pogo Filling Compact Test Head

33 PinScale 400 Configuration
with Analog and DC Scale 1st PS400 card, slot 1-5, , Pos 105 2nd PS400 card, slot 1-6, , Pos 106 1st out 2nd out 3rd out 4th out 5th out 3rd PS400 card, slot 2-8, , Pos 117 4th PS400 card, slot 2-7, , Pos 116 Analog 5th PS400 card, slot 1-1, , Pos 101 6th PS400 card, slot 1-2, , Pos 102 232 231 230 229 228 227 226 225 116 115 114 113 8 7 6 5 432 431 430 429 428 427 426 425 4 3 2 1 112 111 110 109 8 7 6 5 316 315 316 315 314 313 312 311 310 309 312 311 7th PS400 card, slot 1-4, , Pos 104 4 3 2 1 8th PS400 card, slot 1-3, , Pos 103 9th PS400 card, slot 2-5, , Pos 114 314 313 310 309 10th PS400 card, slot 2-6, , Pos 115 11th PS400 card, slot 1-8, , Pos 108 12th PS400 card, slot 1-7, , Pos 107 117 118 119 120 121 122 123 124 101 102 103 104 1 2 3 4 105 106 107 108 317 318 319 320 317 318 321 322 323 324 321 322 5 6 7 8 1 2 3 4 301 302 303 304 301 302 305 306 307 308 305 306 5 6 7 8 1st DC card, slot 1-7, 2nd DC card, slot 1-8, 319 320 323 324 3rd DC card, slot 2-6, 4th DC card, slot 2-5, 5th DC card, slot 1-3, 6th DC card, slot 1-4, Up to 768 digital channels with RF or Analog First 384 digital channels compatible to Ce/C/P (STH) 7th DC card, slot 1-1, 8th DC card, slot 1-2, 9th DC card, slot 2-8, 10th DC card, slot 2-7, Compact Test Head

34 Pogo Mapping File Path: /etc/opt/hp93000/soc/pogo_mapping
For Digital use default file: pogomapping _2CC For Analog / RF use: Non-standard Pogo Mapping Files: pogomapping_2CC_Analog_CONF_A pogomapping_2CC_Analog_CONF_B pogomapping_2CC_Analog_CONF_C pogomapping_2CC_Analog_RF or a customized Pogo Mapping File Enter Non-standard or customized Pogo Mapping Files in the GLOBAL section of the model file as: pogo_cabeling = <filename> This slide describes the relationship between pogo pins on DUT board and card cage in the test head. The 512 pin test head supports 2 card cages. Each cage can contain 8 digital boards or 8 analog modules. The relationship between cage number and group number is irrelevant and the system user needs only to use the group number. The cage numbering is used for internal use only. Channel Assignments - The DUT board silk screen shows channel assignment numbers which correspond to the pin group locations. For the digital channels, the pin assignment is defined by the channel and pin number. The analog module is assigned a channel location only, i.e. a high resolution Digitizer located in The I/O assignment for each module is provided in the module description documentation. This test head configuration includes 32 utility lines, up to 2 System PMUs and up to 8 DPS channels. Compact Test Head

35 Pogo Mapping File Default: pogomapping_2CC
# Mapping for card cage 1 onto group 1 and 3 # Cage 1 slot 1-8 are filled with Pin Scale channel cards # Cage 1 slot 1-4 may be filled with RF cards, then cells need to be edited # , ,118,119,120 , ,122,123,124 , ,318,319,320 , ,322,323,324 , ,102,103,104 , ,106,107,108 , ,302,303,304 , ,306,307,308 ,-1 -1,-1,-1,-1 # Mapping for card cage 2 onto group 2 and 8 # Cage 2 slot 1-8 are filled with Pin Scale channel cards # Cage 2 slot 1-4 may be filled with RF/analog cards, then cells need to be edited , ,430,431,432 , ,426,427,428 , ,230,231,232 , ,226,227,228 , ,314,315,316 , ,310,311,312 , ,114,115,116 , ,110,111,112 ,-1 -1,-1,-1,-1 Pos = (control segment x 100) + slot Cards with 1 Pogo Block (DPS1) Cards with 2 Pogo Blocks (PS800/3600) Cards with 4 Pogo Blocks (PS400) -1 indicates that this type is not allowed:  In DPS Slots no cards with 2 or 4 Pogo Blocks  In Channel Slots no cards with 1 Pogo Block This slide describes the relationship between pogo pins on DUT board and card cage in the test head. The 512 pin test head supports 2 card cages. Each cage can contain 8 digital boards or 8 analog modules. The relationship between cage number and group number is irrelevant and the system user needs only to use the group number. The cage numbering is used for internal use only. Channel Assignments - The DUT board silk screen shows channel assignment numbers which correspond to the pin group locations. For the digital channels, the pin assignment is defined by the channel and pin number. The analog module is assigned a channel location only, i.e. a high resolution Digitizer located in The I/O assignment for each module is provided in the module description documentation. This test head configuration includes 32 utility lines, up to 2 System PMUs and up to 8 DPS channels. Cards with 2 Pogo Blocks (PS800/3600) Cards with 4 Pogo Blocks (PS400) Cards with 1 Pogo Block (DPS2) Compact Test Head

36 Pogo Mapping File With Analog Configuration A
# Mapping for card cage 1 onto group 1 and 3 # Cage 1 slot 1-8 are filled with Pin Scale channel cards # , ,118,119,120 , ,122,123,124 , ,318,319,320 , ,322,323,324 , ,102,103,104 , ,106,107,108 , ,302,303,304 , ,306,307,308 ,-1 -1,-1,-1,-1 # Mapping for card cage 2 onto group 2 and 8 # Cage 2 slot 5-8 are filled with Pin Scale channel cards # Cage 2 slot 1-4 may be filled with analog cards ,428 -1,-1,-1,-1 ,431 -1,-1,-1,-1 , ,-1,-1,-1 , ,-1,-1,-1 , ,314,315,316 , ,310,311,312 , ,114,115,116 , ,110,111,112 ,-1 -1,-1,-1,-1 Cards with 2 Pogo Blocks Cards with 4 Pogo Blocks DPS 1 with 1 Pogo Block This slide describes the relationship between pogo pins on DUT board and card cage in the test head. The 512 pin test head supports 2 card cages. Each cage can contain 8 digital boards or 8 analog modules. The relationship between cage number and group number is irrelevant and the system user needs only to use the group number. The cage numbering is used for internal use only. Channel Assignments - The DUT board silk screen shows channel assignment numbers which correspond to the pin group locations. For the digital channels, the pin assignment is defined by the channel and pin number. The analog module is assigned a channel location only, i.e. a high resolution Digitizer located in The I/O assignment for each module is provided in the module description documentation. This test head configuration includes 32 utility lines, up to 2 System PMUs and up to 8 DPS channels. Analog Cards with 1 Pogo Block Analog Cards with 2 Pogo Blocks Cards with 2 Pogo Blocks Cards with 4 Pogo Blocks DPS 2 with 1 Pogo Block Compact Test Head


Download ppt "Verigy V93000 Service Training"