1 Sterilization (continued)
CP504 – Lecture 17 Sterilization (continued) Learn about thermal sterilization of liquid medium Learn about air sterilization Learn to do design calculations R. Shanthini Nov 2011

2 Continuous Sterilization:
Simplifies production planning Therefore gives maximum plant utilization and minimum delays Provides reproducible conditions Can be operated at high temperature (1400C) Therefore sterilization time can be reduced (2 to 3 min) Requires less steam and less cooling water Suitable when the capacity of operation is high High initial capital investment (use of aseptic transfer system for the sterile broth to be transported to a sterile vessel) R. Shanthini Nov 2011

3 Continuous Sterilization:
It is the only option if the medium is to be exposed to high temperatures for a short time (HTST process) to avoid denaturation of proteins or to avoid destruction of some of the enzymes, etc., since it is not possible in commercial scale operations in batch sterilization to quickly heat large volumes of the medium in short time and cool it also in short times. R. Shanthini Nov 2011

4 sterilization takes place)
Continuous Sterilization: Continuous Injection Type Steam Raw medium Expansion valve vacuum Holding section (where most of the sterilization takes place) Flash cooler - Direct steam injection for heating (relatively a rapid process) - Flash cooling (rapid process) Sterile medium R. Shanthini Nov 2011

5 Continuous Sterilization:
Continuous Injection Type Capital investment is low Easy to clean and maintain the system Heating and cooling periods are shorter Steam efficiency is very high as live steam is directly injected into the medium Direct contact of the steam with the medium makes it necessary that the steam should be clean and free of any anti-corrosive agents Foaming may occur during both heating and cooling R. Shanthini Nov 2011

6 Continuous Sterilization:
Continuous Heat Exchanger Type Sterile medium Steam Holding section Indirect steam heating in plate-and-frame (or shell-and-tube) heat exchanger Raw medium Cooling water R. Shanthini Nov 2011

7 Continuous Sterilization:
Continuous Heat Exchanger Type plate-and-frame heat exchanger has larger heat transfer area than shell-and-tube heat exchanger, and therefore more effective plate-and-frame heat exchanger is favourable with high viscous system plate-and-frame heat exchanger is limited to lower pressures (less than 20 atm) due to its weak structural strength R. Shanthini Nov 2011

8 hold Continuous Sterilization:
Most of the sterilization in the continuous sterilization process may occur in the holding section. Therefore no hold = ln = kd λhold = kd0 exp(-Ed/RT) λhold nt Since the holding section is a long pipe, length of the pipe L uav λ = hold average fluid velocity in the pipe R. Shanthini Nov 2011

9 Continuous Sterilization:
The ratio of average velocity to maximum velocity uav = 0.5 for laminar flow of Newtonian fluids through a smooth round pipe umax = 0.75 for turbulent flow = 0.87 for turbulent flow with the Reynolds Number of 1000,000 Therefore, using the average velocity to calculate the length of the pipe required for sterilization may leave some portion of the medium understerilized, which may cause contamination problem R. Shanthini Nov 2011

10 Example 10.4: Estimating the time required for continuous sterilization
A continuous sterilizer with a steam injector and a flash cooler will be employed to sterilize medium continuously with the flow rate of 2 m3/h. The time for heating and cooling is negligible with this type of sterilizer. The typical bacterial count of the medium is about 5 x 1012 per m3, which needs to be reduced to such an extent that only one organism can survive during two months of continuous operation. The sterilizer will be constructed with the pipe with an inner diameter of m. Steam at 600 kPa (gauge pressure) is available to bring the sterilizer to an operating temperature of 125oC. For the heat resistant bacterial spores: kdo = 5.7 x 1039 per h; Ed = x 105 kJ / kmol. For the medium: c = kJ/kg.K; ρ = 1000 kg/m3; μ = 4 kg/m.h. a) What length should the pipe be in the sterilizer if you assume ideal plug flow? b) What length should the pipe be in the sterilizer if the effect of axial dispersion is considered? Assume an axial dispersion coefficient of 20 m2/h. R. Shanthini Nov 2011

11   kd dt = Solution to Example 10.4:
Problem statement: The typical bacterial count of the medium is about 5 x 1012 per m3, which needs to be reduced to such an extent that only one organism can survive during two months of continuous operation. n0 = (5 x 1012 per m3) x (2 m3/h) x (24 h/day) x (60 days) = x 1012 nt = 1 = kd dt t ln n0 nt = 144x1014 = ln = 37.2 1 The above integral should give 37.2. R. Shanthini Nov 2011

12 hold Solution to Example 10.4:
a) Since the temperature at the holding section in constant, hold = kd λhold = 37.2 For the given data, kd = kd0 exp(-Ed/RT) = (5.7 x 1039 per h) exp[ x105 / 8.314x( )] = per h Therefore, λhold = 37.2 / kd = 37.2 / per h = h Length of the pipe, L = velocity through the pipe x λhold = velocity through the pipe x h R. Shanthini Nov 2011

13 Since plug flow is assumed, velocity through the pipe = 2 m3/h
Solution to Example 10.4: Since plug flow is assumed, velocity through the pipe = 2 m3/h = 245 m/h π (0.102/2)2 m2 Therefore, L = (245 m/h) x (0.099 h) = m What happens if the flow is not plug flow? R. Shanthini Nov 2011

14 Axial dispersion coefficient
Solution to Example 10.4: b) If axial dispersion is considered, then we use the following table: uav L D Peclet number = nt n0 Axial dispersion coefficient kd L uav R. Shanthini Nov 2011

15 is obtained from the table
Solution to Example 10.4: uav L D (245 m/h) x ( L m) (20 m2/h) Peclet number = = kd L uav (375.3 per h) x ( L m) (245 m/h) X-coordinate = = nt n0 Y-coordinate = is obtained from the table R. Shanthini Nov 2011

16 Solution to Example 10.4: If L = 25 m is tried, we get uav L D
(245 m/h) x ( 25 m) (20 m2/h) Peclet number = = = 306 kd L uav (375.3 per h) x ( 25 m) (245 m/h) X-coordinate = = = 38.3 nt n0 Y-coordinate = = > 6.9 x 10-17 R. Shanthini Nov 2011

17 Solution to Example 10.4: If L = 27.5 m is tried, we get uav L D
(245 m/h) x ( 27.5 m) (20 m2/h) Peclet number = = = 337 kd L uav (375.3 per h) x ( 27.5 m) (245 m/h) X-coordinate = = = 42.1 nt n0 Y-coordinate = = > 6.9 x 10-17 R. Shanthini Nov 2011

18 Filtration: Sterilize solutions that may be damaged or denatured by high temperatures or chemical agents. The pore size for filtering bacteria, yeasts, and fungi is in the range of μm The pore size for filtering viruses and some large proteins is in the range of 0.01 μm R. Shanthini Nov 2011

19 Methods for gas (air) sterilization:
Aerobic fermentation require huge volumes of air (a 50,000 L fermenter requires 7x106 to 7x107 L per day of air) which must be sterilized. Adiabatic compression of process air can increase air temperature (150oC to 220oC). A temperature typically of 220oC for 30 s is required to kill spores. An air-filtration step is almost always used to ensure sterility of process air. Depth filters use glass wool, and rely on inertial impaction, interception, diffusion and electrostatic attraction (explained later). Surface filters using membrane cartridges use the sieving effect (explained later). R. Shanthini Nov 2011

20 Filtration mechanisms operating in depth filters
R. Shanthini Nov 2011

21 Filtration mechanisms operating in depth filters
Inertial impaction (or impingement) occurs when a particle travelling in the air stream and passing around a fibre, deviates from the air stream (due to particle inertia) and collides with the fibre. Impaction is the dominant collection mechanism for particles larger than 0.2 μm. It is important in removing bacteria. R. Shanthini Nov 2011

22 Filtration mechanisms operating in depth filters
Interception occurs when a large particle, because of its size, collides with a fibre in the filter that the air stream is passing through. Interception is the dominant collection mechanism for particles greater than 0.2 μm. It is important in removing bacteria. R. Shanthini Nov 2011

23 Filtration mechanisms operating in depth filters
Diffusion occurs when the random (Brownian) motion of a particle causes that particle to contact a fibre. Diffusion is dominant for particles less than 0.2 μm. It may be important for virus removal, but bacteria are sufficiently large that diffusion is relatively unimportant. R. Shanthini Nov 2011

24 Filtration mechanisms operating in depth filters
Electrostatic attraction plays a very minor role in mechanical filtration. After fibre contact is made, smaller particles are retained on the fibres by a weak electrostatic force. R. Shanthini Nov 2011

25 Filtration mechanisms operating in surface filters
R. Shanthini Nov 2011

26 Concerns in air sterilization:
Pressure drop is critical in a filter. Energy input for compressed air for a commercial-scale process is significant. Air treatment can account for 25% of total production costs. Design engineer has to balance the assurance sterility against the pressure drop. R. Shanthini Nov 2011

27 180M3 Fermenter Plant Air Compressor R. Shanthini Nov 2011 27

28 Air Filters in Fermentation Plant
R. Shanthini Nov 2011 28

29 Air sterilization note from Lee was handed over.
R. Shanthini Nov 2011 29