Download presentation
Presentation is loading. Please wait.
Published byDarrell Blake Reynolds Modified over 9 years ago
1
Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ
2
Random air leaks do not provide effective fresh air through a home Depends on temperature difference, wind, exhaust
3
Random air leaks do not provide effective fresh air through a home Where are the holes?
4
Random air leaks do not provide effective fresh air through a home Where are the holes?
5
Random air leaks do not provide effective fresh air through home Where are the holes?
6
Random air leaks do not provide effective fresh air through home Where are the holes?
7
Ventilation Basics How does ventilation work ? How much ventilation do I need in my climate ?
8
Ventilation is not a cure-all Limit and control pollutants at the source carbon monoxide asthma triggers moisture allergens particles radon VOCs chemicals etc. etc. etc.
9
Limit moisture sources Cook with lids Keep bathroom doors closed until moisture is removed No indoor clothes lines Limit indoor plants
10
Capture & Remove moisture at source: Showers Cooking Laundry
11
Ventilation Examples 1,500 Sq Ft House 70 degrees indoor air temperature 85% outdoor relative humidity Let’s look at what happens at … 1. 30 degrees outdoor temp ? 2. 50 degrees outdoor temp ? 3.What happens if we double the indoor moisture load?
12
Ventilation (Air Changes Per Hour) VS Indoor Relative Humidity (%) Indoor Relative Humidity (%) 1,500 ft sq house 70 0 F indoor temp 85 % outdoor RH 30 0 F outside temp typical moisture load.35 AC/h based on G. Tsongas l l.35 l l l l l l l l l l l l l Ventilation: Air Changes per Hour (AC/h) Extreme Ventilation Makes Little Difference
13
Ventilation (Air Changes per hour) VS Indoor Relative Humidity (%) Indoor Relative Humidity (%) 1,500 ft sq house 70 0 F indoor temp 85 % outdoor RH 50 0 F outside temp typical moisture load.35 AC/h based on G. Tsongas l l.35 l l l l l l l l l l l l Ventilation: Air Changes per Hour (AC/h)
14
Ventilation (Air Changes Per Hour) VS Indoor Relative Humidity (%) Indoor Relative Humidity (%) 1,500 ft sq house 70 0 F indoor temp 85 % outdoor RH 30 0 F outside temp typical moisture load 2 X moisture load 50 0 F outside temp typical moisture load 2 X moisture load.35 AC/h based on G. Tsongas l l.35 l l l l l l l l l l l l l Ventilation: Air Changes per Hour (AC/h)
15
Drying Potential of Outside Air: The colder the outside air, the more drying effect when this air is warmed inside Warm, humid air has much less drying potential (can cause problems)
16
Good News for Energy & Comfort When it’s cold outside: need less air exchange When it’s mild outside: need more exchange
17
Exhaust Moisture at the Source
18
Fan & Light Switch Fan delay time 1 to 60 minutes
19
If double pane windows are getting foggy on the room side, condensation & mold growth are on the way…
20
Comfort, Moisture, Noise, Pollen, Dust, Odors, Security Open Windows for Ventilation?
21
Ventilation Systems 1.Central Exhaust 2.Multi-port Exhaust 3.Heat Recovery Ventilator (balanced)
22
Dry air in Exhaust Fan Dry air in Wet air out Central Exhaust
23
Manual and Automatic Controls
24
Should operate 24 hours per day
25
2 Speed Whole House Fresh Air Fan Low speed 24/7 continuous fresh air High speed for odors odors moisture moisture VOCs VOCs particles particles etc. etc. Fan off delay timer Super Quiet
26
Motion Sensor turns fan to high speed turns fan to high speed 24/7 Low Speed CFM Setting Fan off delay timer
27
24/7 Low Speed CFM Setting Fan off delay timer
29
Air Inlets Built Into Window Frame
30
Through-the-Wall Fresh Air Vent
31
Ventilation Systems Central Exhaust Multi-port Exhaust Heat Recovery Ventilator (balanced)
32
Air out thru roof Air out from rooms in home Exhaust fan in Box Unit suspended in attic
36
Bedroom Central Zone Bathroom Bedroom
37
Bathroom exhaust grill about 20 CFM Continuous 65 -80 CFM High Speed
38
Bedroom exhaust grill about 10 CFM each room continuous
39
Ventilation Systems Central Exhaust Multi-port Exhaust Heat Recovery Ventilator (balanced)
41
Heat Recovery Ventilation Stale Moist Exhaust From House Tempered Fresh Air Into House Outside Fresh Air to House Stale House Air Exhaust
42
Outside Air Supply Air Return Air Exhaust Air Defrost Damper
44
Airborne Mold Sampling EPA, ACGIH* and other peer reviewed guidelines do not recommend airborne mold sampling as part of an investigation or remediation… *American Congress of Governmental Industrial Hygienists
45
It is very unlikely that airborne mold samples will provide evidence that cannot be more easily and reliably obtained by a thorough inspectio n Airborne Mold Sampling
46
Airborne Sampling can produce False Negatives.. but not False Positives “Absence of Evidence is NOT Evidence of Absence”
47
Consensus is that traditional methods used to identify increased mold exposure do not reliably predict increased health risks. California Department of Public Health Statement on Building Dampness, Mold, and Health, September 2011
48
Current practices for collection, analysis, and interpretation of environmental samples for mold… cannot be used to quantify health risks posed by dampness and mold in buildings or to guide health- based actions. California Department of Public Health Statement on Building Dampness, Mold, and Health, September 2011
49
Current consensus does not justify the differentiation of some molds (such as Stachybotrys species) as “toxic molds”
50
California Department of Public Health Statement on Building Dampness, Mold, and Health, September 2011 The only types of evidence that have been related consistently to adverse health effects are: current or past water damage, damp materials, visible mold, mold odor. But not the number or type of mold spores nor the presence of other markers of mold in indoor air or dust.
51
The most effective tool for locating mold growth and building dampness: a detailed site inspection, understanding moisture dynamics, building science fundamentals. (Light, 2009)
52
One set of investigations based on detailed building inspection, Parallel investigations based on mold testing. Results indicated that extensive collection of air and surface samples failed to identify mold growth in addition to that observed using visual indicators. Moreover, the inspector using visual cues located hidden mold growth undetected by sampling in half of the cases (6 of 12). (Light, 2009) 12 cases where opposing experts evaluated the same water damaged site:
Similar presentations
© 2024 SlidePlayer.com Inc.