Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 On A Laboratory, “Magnetic Resonance” Experimental Set up This is an Animated feature Viewable ONLY with the MS PowerPoint XP Version. Other versions.

Similar presentations


Presentation on theme: "1 On A Laboratory, “Magnetic Resonance” Experimental Set up This is an Animated feature Viewable ONLY with the MS PowerPoint XP Version. Other versions."— Presentation transcript:

1

2 1 On A Laboratory, “Magnetic Resonance” Experimental Set up This is an Animated feature Viewable ONLY with the MS PowerPoint XP Version. Other versions would not enable all the animation Features Effectively. An Elaboration required by the Students in M.Sc., Physics Laboratory in particular for the Modulation Features for the ESR signal display system. If your System, the P.C. Unit, has the Multimedia facilities installed, then turn the Audio features on with optimal settings Each Slide is set to transit to the next on a MOUSE CLICK after the following instruction is animated “CLICK to transit to the next Slide”

3 2 A Thumb rule to work out Electron Spin Resonance Frequency is as follows: since hν=gβH is the relation governing resonance condition, by knowing the relevant constants from available data tables, it should be verified that the following equation closely approximates the resonance frequency-field criterion for ESR.resonance 1 Gauss = 2.8 MHz for a free electron spin with g=2 Therefore if one can detect the oscillator levels using an oscillator- detector, and, if the frequencies of the oscillations are in the range of 8-32 MHz, then using the above equation the corresponding resonance field can be calculated. 2.9 – 11.5 Gauss. Further a simple Helmholtz coil can be designed to obtain these Magnetic Field Strengths by providing a suitably designed current sources which may be available even commercially. Then a Block Diagram of the type shown in the next slide can be appropriate for constructing and assembling a esr detection system. CLICK to transit to next slide

4 3 Oscillator Oscillation Level Detector Current Source Oscillation Level at fixed frequency ‘ν’ When No ESR Oscillation Level reduced when there is ESR absorption Detected DC Level No ESR Reduced DC On ESR Absorption hν=gβH No oscillations 0 1 2 If the Current is increased from 0 to beyond resonance field, then, the field [ H t ] increases with time and causes resonance at resonance field value 2 1 hν=gβ H The role of a phase Φ shifter in the diagram would be explained in the succeeding slides CLICK to transit to next slide Φ Shifter HtHt

5 4 Since the Magnetic Field values are in the range of 10 gauss only instead of a steadily increasing field a sinusoidal field variation with time can be generated and the magnetic field can be swinging back and forth about zero field value and the peak value of this sinusoidal field variation can be larger than the resonance field value. Thus from zero while swinging positive the resonance can occur, next when from the peak positive value when the field swings towards zero once more there will be resonance. Since ESR resonance condition can be valid without any regard to field directions but depending only on the magnitude, there can be twice resonance during the negative swing. Thus the Resonance Condition is better expressed by h ν = g β |H| This sinusoidal variation has the time dependence as below: H t = H p sin ( 2π f t + φ ) H t is the instantaneous value of the Field and H p is the peak value during the sinusoidal variation of the field with time. Φ is the phase of this variation. f is the frequency of the variation which is significantly small only of the order of few tens Hertz while the ESR resonance frequency would be in the Megahertz range. This field variation is caused by an electrical current and this electrical signal can be applied to the X axis of an oscilloscope display while the Y axis would be the detected RF signal – a DC, in the absence of the time varying magnetic field. In this process there can be phase differences in the sinusoidal variation of the Magnetic Field and the X axis trace of the oscilloscope and it would be necessary to introduce a phase shifter in the circuit. Click to transit to next slide

6 5 Cursor arrow position indicates H t In Phase Modulation Peak to Peak modulation amplitude =2H p -H P to +H P hν = gβH resonace condition encountered twice: 1 st at +H : 2 nd at -H 0 +H -H Sinusoidal Field Variation with Center zero Current on X input 1 2 Click & transit to next Slide

7 6 hν = gβH resonace condition encountered twice: 1 st at +H : 2 nd at -H 0 +H -H Sinusoidal Field Variation with Center zero Current on X input a b a b Out of Phase Modulation 1 2 CLICK to transit to the Last slide of this slide show

8 7 An Assignment The illustration till now demonstrated the consequence of a 90º phase shift between the sinusoidal modulation of the Field and the Input to the X axis of Oscilloscope. Obviously the field variations can be described with a Sine function where as in the second setting the X axis input was Cosine function. Try to make a similar Animated feature for phase difference of 10º, 45º, and 60º and view the resulting sequence in which the several resonance coincidences occur and visualize what the oscilloscope display would be for a modulation frequency of about 60Hz. CLICK to transit to the First Slide


Download ppt "1 On A Laboratory, “Magnetic Resonance” Experimental Set up This is an Animated feature Viewable ONLY with the MS PowerPoint XP Version. Other versions."

Similar presentations


Ads by Google