TeSys T Motor Management System

Similar presentations


Presentation on theme: "TeSys T Motor Management System"— Presentation transcript:

1 TeSys T Motor Management System
Customer Presentation

2 Summary Motor starters TeSys T Overview TeSys T in detail Conclusion
A wide range of solutions TeSys T Overview Offer introduction Targeting & Application Associated Features Customer benefit Unique Value Proposition TeSys T in detail Components & Combinations Main Functions: Control, Protection, Monitoring Conclusion

3 Summary Motor starters TeSys T Overview TeSys T in detail Conclusion
A wide range of solutions TeSys T Overview Offer introduction Targeting & Application Associated Features Customer benefit Unique Value Proposition TeSys T in detail Components & Combinations Main Functions: Control, Protection, Monitoring Conclusion

4 A wide range of solutions
D Contactors F Contactors K Contactors Bar Contactors Mounted Motor Starters - Enclosures TeSys T Motor Management System New A large & worldwide offer Motor Starters Switches / Fuses Disconnectors International standards GV2 Circuit Breakers GV7 Circuit Breakers GV3 Circuit Breakers Colocar Cofre Tesys U, colocar GV2-P, arrumar imagens dos reles, aumentar tamanho Serie K, Electronic Relays Motor & Equipment Protection LR Thermic Relays

5 Summary Motor starters TeSys T Overview TeSys T in detail Conclusion
A wide range of solutions TeSys T Overview Offer introduction Targeting & Application Associated Features Customer benefit Unique Value Proposition TeSys T in detail Components & Combinations Main Functions: Control, Protection, Monitoring Conclusion

6 TeSys T: as result of customer needs
Full functionality, protection and monitoring availability by means of configurable control in remote control through network in local control when bus system fail Safe design and high degree of applicability Integrated Power & Control up to high ratings Main Protections & Control functions in one device Accurate measurement Solid - state full motor protection ensuring long term stability of tripping characteristics Numerous alarms & trip thresholds Basic overload & the more demanding protections based on temperature sensor, earth leakage & voltage Sharp analysis of motor operating conditions Monitoring and operation statistics

7 A comprehensive and advanced offer
Ethernet TCP/IP Native protocol connectivity X X Controller expansion module Additional protection functions Control Unit Operator Q32007 PC with Power Suite or Remote control and monitoring Operator terminal The TeSys T motor controller management system allows to increase protection, control and monitoring capabilties for single and 3 phase induction motor. The offer is composed of : # Controller rated from 0,4 amp to 100 amp # Optional expansion module allows Voltage and Powerprotection functions # Optional operator terminal for the configuration and monitoring of the controller # PowerSuite software for the programming, configuration and monitoring of the controller # Additional external current transfomers to expand the current range up 810 amp # Additionnal ground current transfomers for precise ground protection External CT For up to 810A Ground CT Hearth Leakage protection

8 Offer introduction and related features
Advanced Functions Easy Implemenation Strong Adapbility Control functions Local or remote control Pre-defined operating modes Custom operating mode Fault management Optional components Removable terminal strips Complementary auxiliaries Communication with PLC/DCS through Ethernet TCP/IP Protection functions Thermal Overload protections Voltage protections Current protections Power protection Configuration through Magelis HMI PLC/DCS PowerSuite SoftWare As a full, flexible motor management system, TeSys T can provide Advanced functions which could be divided into 3 groups: Control functions including pre-defined operating modes, custom operating mode, local remote control switching and fault management. Protection functions which are the most important for a motor as well as the continuity of the service. And Monitoring functions which are also very important for mastering the status of the motor. Other than the functions provided, TeSys T also afford the availability for easy configurations: It supports 5 different communication networks: modbus, profibus, canopen, devicenet and ethernet tcp/ip, and could be set up through either Magelis HMI or PLC or Powersuite software. Metering and Monitoring functions Current / Voltage / Power measurement Statistics / Diagnostics Motor states Fast Installation Plate mounting and iMCC drawer installation Embedded CT, “Passing” connection Segment coverage Advanced functions and extended configurability to meet most needs of motor applications in industry

9 Targeting: priority sectors
“Energy & Infrastructures” Oil & Gas processing Petrochemical Refinery, Offshore Platform Water Water treatment “Industry” Mines Minerals & Metals Cement Glass Steel Ore-Extraction Microelectronic Pharmaceutical Chemical Industry Cosmetics, Detergents, Fertilisers, Paint “Other opportunities” Other opportunities Food & beverage Airports Road Tunnels “Wherever productivity is a concern” “Wherever operation and maintenance constraints impose centralization of motor starters”

10 Targeting: general Market trend
End-users of mixed and continuous process sites are looking for higher efficiency and competitiveness therefore are using electricity more and more as primary energy Improved motor control can bring massive progress Better control and protection for motors and process Reduce installation global cost (electrical distribution+ monitoring) Reduce process downtime Simplify future expansion and upgrade Intelligent Motor Protection Relays provides massive advantages compared to bimetallic overloads Intelligent Motor Control Relays prices are decreasing year after year MCC very quickly shift to Intelligent MCC (iMCC)

11 Targeting: Power & Control architecture
Information flow Energy flow Others Instrumentation Process control MV PCC iMCC

12 Targeting: Low Voltage Switchboard
Motor Control Center “Non Schneider” iMCC Technical Room

13 Find your convenience! Freely combine your conveniences
Native connectivity to all main Protocols: Ethernet, Modbus, CanOpen, Profibus & DeviceNet Freely combine your conveniences All in device for main protection & control features. Optional Expansion module for Voltage and Power Easy Commissioning & Control. Multi choice of interface HMI, PC or Network. Wide range design: 3 rating up to 100 A without external CTs. High voltage digital input ( VAC) without additional module

14 engineering & commissioning time
Find your convenience! Simplification of the schemes design thanks to predefined operating mode and high ability of motor control & protection functions Save engineering & commissioning time Speed up process start-up through diagnostic data to correct wrong setting & easy adaptation. Reduce error risk through predefined operating mode Easy & quick integration inside of any kind of Low Voltage switchboard. Consistent with Schneider Electric iMCC offer: Okken, Blokset & Model 6 Faster implementation & space saving thanks to less components and hence less cabling. Faster configuration through PowerSuite uploading

15 process downtime & maintenance cost
Find your convenience! Process availability thanks to high level protection. Electronic technology provides high accuracy & reliability. Guaranteed protection in case of bus fail Reduce process downtime & maintenance cost Reduce maintenance cost thank to faster problem fixing: detailed diagnostic & statistic for preventive maintenance. Cut stock of spare parts as one multifunction device Prevent untimely downtime through acquisition and monitoring of operational & diagnostic data: alarms before tripping; detailed log of trip condition for improvement Cut down system failure risk thanks to TeSys T safe design. Power & Control integrated in the same device: no flat cables. Less components less failure

16 choice of Motor Management System
Unique Values “TeSys® range Values” Leader in Motor Protection & Control Availability “Schneider Electric MCC offer” Proven & Branded Trust-Mark Acceleration & Simplification of purchasing process Simply Smart !” Standardization “Native Open Connectivity” Multiple Networks: MODBUS Ethernet TCP/IP Freedom of choice of Motor Management System

17 Simply Smart !” Unique Values Productivity Optimization “Integrated
“High degree of Applicability” Exhaustive P&C functions Wide range & Multiple networks Consistency of mapping “Form factor & Installation System” Okken (75 mm drawer), Blokset & Model 6 Optimization Space Saving Time saving Safe solution Cost saving Simply Smart !” Productivity “Integrated Design” Integrated CT up to 100 A Mains Protection & Control functions integrated Safe Design Robustness Quality

18 Summary Motor starters TeSys T Overview TeSys T in detail Conclusion
A wide range of solutions TeSys T Overview Offer introduction Targeting & Application Associated Features Customer benefit Unique Value Proposition TeSys T in detail Components & Combinations Main Functions: Control, Protection, Monitoring Conclusion

19 A comprehensive and advanced offer
Native protocol connectivity X X Ethernet TCP/IP Additional protection functions Controller expansion module Q32007 or Remote control and monitoring Operator terminal PC with Power Suite Control Unit Operator The TeSys T motor controller management system allows to increase protection, control and monitoring capabilties for single and 3 phase induction motor. The offer is composed of : # Controller rated from 0,4 amp to 100 amp # Optional expansion module allows Voltage and Powerprotection functions # Optional operator terminal for the configuration and monitoring of the controller # PowerSuite software for the programming, configuration and monitoring of the controller # Additional external current transfomers to expand the current range up 810 amp # Additionnal ground current transfomers for precise ground protection For up to 810A External CT Hearth Leakage protection Ground CT

20 Motor Management Controller
Front layout Power Supply 6 Discrete inputs (internal powered inputs) 1 Fault relay output (NO/NC) Plug-in terminals Diagnostic Leds Expansion module/ HMI/PC connection (modbus RS485) Network connection (RJ45 port) Reset or Self test Button 3 relays outputs 5A Ground fault input Probe temp. Network connection (screw terminal)

21 Motor Management Controller
Network Protocol connectivity 4Q2007 2Q2007 TeSys Port: Ethernet/Modbus Ethernet TCP/IP

22 Motor Management Controller
Integrated CT for current range up to 100A Loops for adapting the current More loops increase the accuracy External CT to expand the current range up to 810 A Controller accept 5A and 1A secondary signal from external CT External load CT LT6CT... or LUTC… or Customer Choice

23 Motor Management Controller
External ground CT for precise ground protection Measures as a level significantly lower than internal ground fault (20 mA to 10 A) Ground fault CT (current =0 => no ground fault)

24 Expansion Module Power Supply Assembling Powered by Controller
Side by side or Remote Additional Motor Protection Over / Under Voltage Over / Under Power Factor Over / Under Power Load shedding Additional Input 4 discrete inputs

25 Expansion Module Front layout
3 Phase inputs Voltage (0 to 690 VAC) HMI/PC connection Controller RJ45 port Status indication Leds Expansion module powered by the controller 4 discrete inputs (external powered inputs)

26 Operator Terminal Mahelis XBTN410: Configuration, Display & Control
One to One Application One to Many Application Magelis XBTN410 Local Control Configures parameters Displays real-time values Alarm monitoring 24V DC supply needed XBTZ938 cable Modbus protocol for data tranfering

27 Operator Terminal Control Operator Unit: Configuration, Display & Control Available on 3Q2007 One to One Application LTMCU Device Local Control Configures parameters Displays real-time values Alarm monitoring Powered by MMC XBTZ938 cable

28 One to One Application or One to Many Application
PowerSuite Software Configuration, Display & Control One to One Application or One to Many Application PowerSuite Software Configures parameters Displays real-time values Alarm monitoring Logic block programming RS232/485 Converter: VW3A8106 Direct ethernet 8 pin cable: VW3A8306R10

29 Network architecture PLC DCS Ethernet TCP/IP A15
TeSys T on the network : Remote Control Configures & sets up the functions Monitoring Network Connection Port on the front (picture shows RJ45 for Modbus) Terminal Strip (For DeviceNet, only terminal strip is presented)

30 Part number

31 Motor Control Functions
Depending on the controller configuration Control functions Controller Controller & expansion module Motor Control Modes Local mode : Terminal strip or HMI Remote mode Operating Modes Overload Independant Reverser Two-step Two-speed Custom mode Fault Management Manual reset Automatic reset Remote reset

32 Power Wiring 1 1 Circuit breaker 2 Contactor
3 4 5 7 6 8 Expansion module Controller 1 1 Circuit breaker 2 Contactor 3 Control power supply (24VDC / VAC) 6 HMI or Powersuite port connection 7 Cable connection (controller & expansion) 8 Network port 4 Ground fault current transformer 5 PTC thermistor (binary or analog)

33 Control Wiring 6 logic input - Internal supplied power
Fault relay output 97-98: NO ; 95-96: NC 4 logic input require external power isolated with input on the controller 2 control relay output Warning relay output

34 Control Modes - Local Control
Control Through Terminnal Strips Network Monitor Through Network Control Through Magelis HMI Control local mode selection is defined by input I.6: 0= Local mode Control local channel setting: 0= Local Terminal, 1= Local HMI Local Stop Command will always be responded regardless of the control mode

35 Control Modes - Remote Control
Terminals only for Signal Input Network Control Command Through Network HMI only for Monitoring Control Remote mode selection is defined by input I.6: 1= Remote mode The bumpless parameter determines the behavior of outputs O1 & O2 when changing control mode. If this parameter is enable the outputs remain the same position when there is a changing control mode. Local Stop Command will always be responded regardless of the control mode

36 Operating Modes Pre-configured operating mode Custom operating mode
Overload : The Start/Stop of the motor is realized by a mechanism other than the controller Independent : Direct on line full voltage non reversing motor starting Reverser : Direct on line full voltage reversing motor starting Two-Step : Reduced voltage starting motor Two-Speed : Two-Speed motor for motor types : Dahlander, Pole Changer Custom operating mode PowerSuite logic editor : provides logic functions (Boolean, Register, Timers, Counter,…) that manage the controller behavoir to create a user mode Note : The selected operating mode determine the behavior of all controller inputs and outputs.

37 Operating Modes Example
The switch Start/stop command the relay output O1 The diagram is an example using the Tesys T in a Direct-On-Line starting motor 2 wire control : input remain active as long as an active signal is present on the input The following diagram represetns a simplified example of the controller in a 2 wire local control overload application. In the independant operating mode, the start/stop of the motor is performed by the controller 2 Wire D.O.L. Control

38 Operating Modes Example
The Start push button I1 commands contactor KM1then KM2 and in a second time the contactor KM3. The diagram is an example of the Tesys T reduced voltage starting motor such as Wye-Delta (see picture) or Open transition primary resistor or open transition autotransformer Transit Conditions (step 1 to step 2) : Motor step 1 to 2 time out or current falling below the motor step 1 to 2 threshold An another wiring diagram which represents a simplified example of the controller in an two-step Wye-Delta local control 3 wire application. In this operating mode, the two-step starting motor is performed by the controller. 3 Wire Star-Delta Control

39 Custom Operating Mode - 2 Languages
Possibility to use an existing logic file to modify the logic command that manage controller behavior Function Block Diagram List Language An another wiring diagram which represents a simplified example of the controller in an two-speed for Dahlander motor local control 3 wire application. In this operating mode, the two-speed starting motor is performed by the controller.

40 Motor Protection functions
Depending on the controller configuration Controller Controller & Expansion module Functions Current Thermal overload (inverse & definite time) Current phase (imbalance, loss, reversal) Under/OverCurrent Long start, Jam Ground current Motor temperature sensor Rapide cycle lockout Voltage Voltage phase (imbalance, loss, reversal) Under/OverVoltage Voltage load shedding Power Under/OverPower factor Under/OverPower

41 Metering & Monitoring Functions
Controller Controller & expansion module Metering and monitoring functions Measure Thermal capacity & motor temperature Power (power active/reactive, power factor) Voltage (line to line, imbalance, frequency) Current (line, average, ground, ph. imbalance) Statistics Fault history Motor control function counts Diagnostic fault counts Protection fault counts Diagnostics Connection (CT, temperature sensor, comm.) Internal watchdog faults, internal temperature Control command Motor states Motor control states, motor operating time Max. current & start time of the last start Time to trip & time to reset

42 Metering & Monitoring Functions
Monitoring Interface Notes :

43 Monitoring: Statistics
Counting log for every kind of faults Protection faults : overload, overcurrent, … Diagnostics faults : HMI port com loss, internal fault, … Recording the motor control history Motor starts count and operating time Motor starts per hour Rapid cycle lockout count Load shedding count Last start record Recording the last 5 faults Fault code Date and time Value of parameters & measurements

44 Monitoring: Diagnostic faults
Internal faults Watchdog : stack over/underflow Temperature Control command checks Start /stop command (current checking after the command) Run /stop check back (current checking during the stage) Connection fault Current Transformer connection Voltage connection Temperature sensor connection Communication loss Local terminal connection Communication loss : HMI, Network, expansion module

45 Monitoring: Motor states
Operating states Ready Start Run Not ready Thermal overload status Time to trip (before the fault occurs) Time to reset (after a thermal overload occurs)

46 Summary Motor starters TeSys T Overview TeSys T in detail Conclusion
A wide range of solutions TeSys T Overview Offer introduction Targeting & Application Associated Features Customer benefit Unique Value Proposition TeSys T in detail Components & Combinations Main Functions: Control, Protection, Monitoring Conclusion

47 "I use the same device for any protocol network"
Conclusion Native Open Communication "I use the same device for any protocol network" Open to all main communication protocols, TeSys T provide an high level of adaptability in any kind of application High level of applicability "I have everything in one device" The most important Control and Protection features are available through the Controller without any additional optional module. All that make everything easier: Selection, Engineering, Implementation and Utilization Robust design "I want a device that guarantee the continuity of service" Power & Control function in one device

48 for your attention T T hanks