IIIT Hyderabad Analysis of Stroke on Brain Computed Tomography Scans Adviser: Prof. Jayanthi Sivaswamy 4 rd October 2013 Saurabh Sharma 200502024
2
IIIT Hyderabad Outline Introduction –Problem Description Part I : Automatic detection of stroke Part II : Contrast enhancement of stroke tissues Region based Pixel based Conclusions Future Directions
3
IIIT Hyderabad Introduction Stroke, a.k.a cerebrovascular accident is loss of brain function due to disturbance in blood supply. 15 Million people are affected from stroke worldwide.
4
IIIT Hyderabad Stroke, a.k.a cerebrovascular accident is loss of brain function due to disturbance in blood supply. Stoke can be: HemorrhagicIschemic Introduction
5
IIIT Hyderabad Both the hemorrhage and ischemic stroke are fatal in nature. Complete recovery possible in hemorrhage but less so in case of ischemic stroke Most of the damage in case of ischemic stroke occurs within four hours of onset. Each hour of untreated stroke ages the brain by ~3.6 years. Introduction
6
IIIT Hyderabad Treatment Hemorrhage and ischemic stroke have conflicting treatments. Physiological changes in hemorrhage can be detected much earlier than stroke. Lack of tissue information in CT, cannot detect ischemic stroke in most cases before the damage is done. The golden rule is first use CT to rule out hemorrhage and then go for MRI to detect ischemic stroke.
7
IIIT Hyderabad Why choose CT? CT imaging is relatively quick, provides better spatial resolution CT is more widely available than MR scanners in developing countries Cost differential between CT and MRI scans Moreover, if infarct can be detected at the first scan ( CT ) itself then it would save valuable time
8
IIIT Hyderabad Problem Statement To aid in detection of stroke from brain CT scans during all stages of pathology. HemorrhageChronic Acute Hyperacute Normal
9
IIIT Hyderabad Track 1 Hierarchical symmetry based automatic stroke detection framework. Stroke is characterized as an aberration in the otherwise symmetrical distribution of tissues between the left and right hemispheres.
10
IIIT Hyderabad Preprocessing Mid-Sagittal plane detection and rotation correction. Most of the existing methods used tissue symmetry or center of mass based solutions. We devised a novel technique making use of physical structure of the nose to detect the rotation angle.
11
IIIT Hyderabad Level 1 Classification
12
IIIT Hyderabad Level 1 Classification Quantize the histograms of both the hemispheres into 5 bins, 0-50, 50 - 100,…,200-250 Compare the 50-100 and the 200-250 bins from the left and right hemispheres. If the dissimilarity observed is greater than a particular threshold assign the case to hemorrhage to chronic (50-100), hemorrhage (200-250) and normal* (otherwise) bins.
13
IIIT Hyderabad Level 2 Classification
14
IIIT Hyderabad Level 2 Classification Need for a finer symmetry comparison to sort out the acute from the normal + hyperacute cases. Wavelet decomposition of the histogram is done and the energy distribution is computed up to 5 levels in scale-space. A threshold value, computed empirically, is then used to separate out the acute cases based on the energy values.
15
IIIT Hyderabad Level 3 Classification At hyperacute stage, very subtle changes take place in the affected tissues. Most of these changes (~2-3 gray scale levels) are very difficult to identify. As a result, we turn to some of the specific signs demonstrated by hyperacute infarct.
16
IIIT Hyderabad Level 3 Classification The best bet : detect the blurring of gray \ white matter. Difficult to achieve in case of CT imaging due to the image quality, noise etc. We propose using a rough segmentation of the brain tissues into gray \ white matter to determine the presence of stroke. Rough segmentation image.
17
IIIT Hyderabad Level 3 Classification Candidate Selection Infarct Decision Skull based Symmetry detection MRF based Tissue Segmentation Wavelet based Image Enhancement Input CT Image
18
IIIT Hyderabad Level 3 Classification *H. Demirel, C. Ozcinar, and G. Anbarjafari. Satellite image contrast enhancement using discrete wavelet transform and singular value decomposition. IEEE GRS Letters, 7(2):333 –337, april 2010. The input CT image is first striped of the skull. In the next step, the input image is subjected to SVD based image contrast enhancement technique proposed by Demirel et al*. Wavelet based Image Enhancement
19
IIIT Hyderabad Level 3 Classification MRF - MAP based Tissue Segmentation Assuming I.I.D Gaussian distribution at each location Where, L is a random variable denoting the class and S is the site location (x,y)
20
IIIT Hyderabad Level 3 Classification MRF - MAP based Tissue Segmentation To obtain the final mappings, we iteratively find the configuration which has the lowest energy. The method employed is called Modified Metropolis Dynamics (MMD) as it is generally faster and provides a lower energy output. M. Berthod, Z. Kato, S. Yu, and J. Zerubia. Bayesian image classification using markov random-fields. Image and Vision Computing, 14(4):285–295,May 1996.
21
IIIT Hyderabad Level 3 Classification Candidate Selection Infarct Decision Weed out false positives using size and confidence constraints
22
IIIT Hyderabad Qualitative Results Input Image Pre Processed Rough Segmentation Final Result
23
IIIT Hyderabad Qualitative Results Input ImagePreprocessedFinal OutputFollow – up
24
IIIT Hyderabad Quantitative Results Dataset Details. The dataset contains 42 volume CT scans. Out of 42, we have 19 normal, 5 hemorrhagic and 6 each of chronic, acute and hyperacute. In addition, we have the follow up scans of the hyperacute cases. For robust testing, the test data was collected from a wide range of age groups. (7, 15, 20 datasets in age groups 0-30, 30-50, 50 and above respectively)
25
IIIT Hyderabad Quantitative Results
26
IIIT Hyderabad Quantitative Results
27
IIIT Hyderabad Quantitative Results
28
IIIT Hyderabad Failure Cases
29
IIIT Hyderabad Track 2 Enhancement of Early Infarct through Auto-Windowing Early automatic detection difficult. Current detection process used by doctors. Issues with existing tissue contrast enhancement techniques. Propose a novel auto-windowing technique which aims at finding the windowing setting which maximizes the contrast between the normal and stroke affected tissues.
30
IIIT Hyderabad Manual Windowing The process of mapping the 16-bit CT image to the 8-bit display monitors.
31
IIIT Hyderabad Manual Windowing The process of mapping the 16-bit CT image to the 8-bit display monitors. Can bring about either contrast stretching or compression.
32
IIIT Hyderabad Manual Windowing Stroke under different window settings.
33
IIIT Hyderabad Auto Windowing We propose two different approaches for auto windowing. Region based Pixel based
34
IIIT Hyderabad Auto Windowing We propose two different approaches for auto windowing. Use the automatic detection of Track 1 to identify the window settings. Plot the histograms of the stroke affected tissues and their counter-parts in the other hemisphere. Find the gray scale value which best separates the two histograms and use this as the window center. Now choose any window width based on how much tissue information is required. Region based Pixel based
35
IIIT Hyderabad Auto Windowing We propose two different approaches for auto windowing. Region based Pixel based
36
IIIT Hyderabad Auto Windowing We propose two different approaches for auto windowing. Region based Pixel based
37
IIIT Hyderabad Auto Windowing We propose two different approaches for auto windowing. Inspired by binary thresholding mechanism The optimum window setting is defined as one which maximizes the difference in distribution of pixels in the left and right hemispheres. Operation is carried out on two separate images, left and right hemisphere, unlike one in case of thresholding. Several techniques exist but difficult to model two image problem using those techniques. Region based Pixel based
38
IIIT Hyderabad Auto Windowing We propose two different approaches for auto windowing. We modeled our two-image thresholding on the parzen window based thresholding proposed by wang et al. Parzen window is a technique to estimate the probability density P(x, y) at a point (x, y). Region based Pixel based S.Wang, F. lai Chung, and F. Xiong. A novel image thresholding method based on parzen window estimate. Pattern Recognition, 41(1):117 – 129, 2008
39
IIIT Hyderabad Auto Windowing We propose two different approaches for auto windowing. Region based Pixel based Ω l and Ω r are the set of pixels in left and right hemispherical image
40
IIIT Hyderabad Auto Windowing We propose two different approaches for auto windowing. Region based Pixel based
41
IIIT Hyderabad Qualitative Results Experiment Details A set of 15 slices each of hyperacute and normal cases were selected The slices were shown to the radiologists under normal, region-based (W r ) and pixel-based (W p ) automated window settings. Each slice by rated by 4 radiologists, of varied experience, in a blinded review for the presence of hyperacute infarct. Their response and the time taken for decision was recorded.
42
IIIT Hyderabad Qualitative Results Average sensitivity increased from 59.95% (W s ) to 79.97% (W r ) and 84.97% (W p ). ( P = 0.034 for W p, P = 0.040 for W r ) Average specificity increased from 83.3% (W s ) to 98.34% (W r ) and 98.34 % (W p ). ( P = 0.032 for W r ) Overall accuracy of the radiologists increased from 71% (W s ) to 91.6% (W p, p = 0.024) and 89.16% (W r, p = 0.034) The performance of younger radiologists show much more improvement though still not statistically significant.
43
IIIT Hyderabad Summary Presented an unified hierarchical approach for automatic detection and classification of stroke. Our approach models the stroke as a disturbance in the otherwise similar distribution of brain tissue with respect to the mid-sagittal plane The method gives very good recall and sensitivity on hemorrhage, chronic and acute stroke and appreciable performance on hyperacute or early infarct. The hyperacute infarct detection can be used to aid the radiologists in clinical environment.
44
IIIT Hyderabad Summary We also presented an auto-windowing approach to aid the radiologists in detection of early infarct. The perception experiment results show that auto-windowing approach could be applied in clinical settings. The method also hinted at bridging the experience divide by bringing the accuracy of inexperienced radiologists to a very good level.
45
IIIT Hyderabad Future Directions Application to similar problems where early detection of diseases is difficult. One such case is the early detection of brain tumors. Need to test on a larger dataset.
46
IIIT Hyderabad Questions?
47
IIIT Hyderabad Thank You.