1 Contamination Control in
Hydraulic Systems MP Filtri USA Good afternoon L & G Thank you to RB – Invitation Questions – After Graveyard My first objective - Interesting and informative! Thames Barrier ? ? ? Let me talk to you …….. - Benefits - Cont Control 1

2 ICM - Inline Contamination Monitor
MP FILTRI

3 MP Filtri UK Design & manufacture the MP range of contamination monitoring products Based in The Cotswolds in Gloucestershire

4 Design The ICM automatically measures and displays the size and quantity of particulate contamination. With the option for moisture and temperature sensor for various hydraulic medias.

5 Design Cast Aluminium casing with poly membrane high temp cover.
IP Rating IP65 & IP67 EMC Tested ( BN BSEN 31326) Dimensions and Weight 188 x 65 x 142 mm / 1.15Kg

6 Inline Contamination Monitor
Specification Technology LED Based Light Extinction Automatic Optical Particle Counter Particle Sizing 8 Channels >4,6,14,21,25,38,50,70 μm© (To revised ISO 4406 Standard) Reporting Format Calibration MTD ISO , 6, 14µ

7 Inline Contamination Monitor
Measure and displays the following international standards ISO NAS 1638 AS 4059E Table 2 AS 4059E Table 1 ISO 11218

8 Inline Contamination Monitor
Test Time Adjustable seconds (1 hour, Factory set to 120 seconds ) Test Intervals (Programmable) Adjustable 0-24 Hours Data Storage (Programmable) Approximately 4000 tests in the IPC memory. History Scrolling on screen last 10 readings (Results, RH & Temp)

9 Inline Contamination Monitor
Start Delay Delay writing to memory of up 999 readings(Readings still show on screen) Flow Rate 20 – 400ml (Flow indication on screen) Flow Rate Can be disabled for very clean systems ( No 6 micron particles or smaller)

10 Flow Indication Because the ICM uses the time between pulse widths to derive flow its flow output is only an indication, intended for installation guidance. What is worth reinforcing however, is that the primary function of the product is to produce a measurement of cleanliness, and not to act as a flow meter. If the unit produces a contamination measurement, then the flow rate is high enough for it to do so. Because it needs particles to pass through the flow cell to calculate flow, the dirtier a system is, the more statistically accurate the flow output becomes. Conversely, when placed on very clean systems it can have difficulty in working out flow due to the very low number of particles passing through the flow cell. This will not effect the contamination measurement, but it is worth noting that customers may experience lower confidence or no indication at all on clean systems. This is why we offer the ability to disable flow on clean system, otherwise the product defaults to not showing a result. Typically, below ISO 14 we would recommend using this feature.

11 Inline Contamination Monitor
Viscosity Range to Cst Pressure to 400 bar Vibration test 40 G (JCB Standard)

12 Inline Contamination Monitor
Environmental Ambient Temperature to +80 ◦C / -25 to 55 ◦C (K Version) Electrical Supply Voltage 9-36V DC Accuracy Better than +/- ½ ISO code in ISO /- 1 Code across the size range. Power Consumption < 2.2w

13 Inline Contamination Monitor
Connecting the ICM to the Computer The IPC-USBi is separately available as a pre-wired solution for USB (all modern laptops and PCs). External Power supply connection RS 485 To laptop /PC USB To ICM RS485

14 Inline Contamination Monitor
LPA View – Windows base software Windows 96 – Vista Full trend analysis Graphs /Tables Report Generator Export to Excel Remote control One software for CMP range

15 Inline Contamination Monitor
NAS1638 Alarm Levels/ AS 4059 Table 1&2/ ISO 11218 AS 4059 Table 1 ISO 11218 NAS 1638 AS 4059 Table 2

16 Inline Contamination Monitor
ISO 4406 NAS 1638 SAE AS 4059 Table 2 SAE AS 4059 Table 1

17 External Relay Alarms Alarms
The ICM has two switched “External relay alarm” outputs that can be used to signal external equipment in various ways, according to the test results and the alarm settings. There is also a multi-colour front panel light which indicates how the result compares to the set alarm thresholds. The alarm settings are comprehensive and flexible, allowing the ICM to be used in many different scenarios.

18 Inline Contamination Monitor
All ICM versions have a multicolour indicator on the front panel, which is used to indicate the status or alarm state. Green indicates that the test result passed, i.e. none of the alarm thresholds were exceeded. Yellow indicates that the lower cleanliness limit was exceeded, but not the upper one. Red indicates that the upper cleanliness limit was exceeded. Blue indicates that the upper water content limit was exceeded. Red/Blue Alternating indicates both cleanliness and water content upper limits exceeded. Violet indicates that the upper temperature limit was exceeded. The LED can also indicate various fault codes by turning red and flashing white a number of times LED

19 Wiring Connections Common 0 volts
External start button (or PLC output relay) Common 0 volts, Internal relays Internal relay , output 1 Internal relay , output 2 DC Volts + 9 to 36v Common 0 volts RS 485 Data TX RS 485 Data Receive

20 Typical Hydraulic System

21 Installation Options

22 Installation Options

23 Installation Options

24 Installation Options Avoid pressure transients of greater than 100 barg. ● For optimum performance we recommend 1 barg differential across the ICM ● Avoid installing the ICM close to pump outlets (In some circumstances pump ripple can have a effect on particle count) ● For best results a check valve (1 to 2 barg approx) should be installed on the return line to reduce the risk of air backflow.

25 Inline Contamination Monitor
Each ICM supplied consists of the following: • ICM particle counter • Calibration certificate • ICM user manual (CD or USB memory stick) • LPA View CD ROM, software package • LPA View test analysis software manual • Circular connector pre-wired with 2 m cable

26 Inline Contamination Monitor
A pressure compensated flow control valve specifically designed to fit the ICM. This may be needed if the application produces an oil flow that varies outside the working range of the standard unit(20-400ml/min). Tech info Max press 400 bar Usable range bar to 400 bar Flow rate ml/min to 340 ml/min Inlet port- connection to ICM ¼” BSP Outlet port 3/8” BSP

27 Inline Contamination Monitor
Options for communication Modbus Protocol PC/Laptop Ethernet Wireless Bluetooth GPRS

28 Inline Contamination Monitor
How to Order ICM-W-M-K-R-G1 Inline Contamination Monitor G1 - Standard minimess G3 - ¼ BSP G4 - 7/16TH UNF Water Sensor & Temp option (Omit if not required) M - Mineral oil / Viton N – Offshore / selective water based medias / Viton S - Phosphates /Aggressive Medias /Perfluror Elastomer Relays –Two external solid state relays Adds local keypad and graphical display (Omit if not required)

29 Inline Contamination Monitor ATEX
AZ2

30 Benefits Saving money on total cost of filtration eliminating unscheduled filter changes Constant system monitoring = pro-active maintenance = cost savings Constant system monitoring = trending system cleanliness and moisture levels by utilising system memory data = cost savings (Warranty) Prolonging major component life due to pro-active maintenance Save time – high cost processes effectively monitored Pro-active control – The ICM is the low cost, efficient method of system monitoring when system cleanliness or moisture levels are exceeded

31 ICM Thank you Any questions