Presentation is loading. Please wait.

Presentation is loading. Please wait.

AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 1 SCHNEIDER ELECTRIC Solutions.

Similar presentations


Presentation on theme: "AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 1 SCHNEIDER ELECTRIC Solutions."— Presentation transcript:

1 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 1 SCHNEIDER ELECTRIC Solutions

2 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 2 Schneider Electric Automation Solutions Cost-Effective Solutions RTU emulation Off-the-shelf, modular PLCs Supports standards, including ICCP and MMS IED integration using Modbus Plus high-speed network Supports “legacy” protocols, including Modbus, DNP 3.0, L&G 8979, PG&E True plug-and-play Ethernet and web capability Enterprise-Connected Solutions Direct connectivity to utility business systems, including EMS/SCADA/DMS, Outage Management, CIS, Accounting Enterprise integration solutions with LiveData products from Cycle Software

3 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 3 Why Quantum? Quantum is the only PLC specifically designed and engineered for utility applications 125 (250) VDC modules Noise Immunity Sequence of Events (SOE) Inter-bay control scheme Breaker Control (HPO module) Modbus Plus/IED support MMS/ICCP (UCA) for communications Multi-vendor support Quantum is 100% compatible with 984 and Compact 984 controllers systems Designed based on what we’ve learned in over 2000 substation applications with our PLCs... Designed based on what we’ve learned in over 2000 substation applications with our PLCs...

4 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 4 LiveData Quantum Module, 140NOE 5X1 Cycle Software’s LiveData Server embedded in a Modicon Quantum PLC MMS Ethernet Hardware Module -- Fiber Optic or Twisted Pair ICCP Option (Inter-Control Center Communications Protocol/ TASE.2) Live Data flows to: Utility information systems (EMS, SCADA …) other Quantum PLCs controllers from other vendors Communications Front-End for the substation Communicates with devices on Modbus, Modbus Plus Communicates with devices on MMS / UCA Communicates with EMS, SCADA via ICCP over LAN/WAN

5 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 5 MMS An international standard protocol for messaging (Manufacturing Messaging Specification ISO 9506) Lets you send data as named objects that can be anything from simple data points in a register to arrays to complex, nested structures...

6 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 6 ICCP / TASE.2 Inter-Control Center Communications Protocol (ICCP) AKA Tele- control Application Service Element (TASE.2) International standard for real-time utility data exchange MMS for messaging Added services and functionality for secure data exchange between different systems. Utility EMS/SCADA systems from all major vendors have it; Integrators understand it. It’s designed for system-to-system communication.

7 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 7 Enterprise Connectivity

8 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 8 Standards Work with the present; plan for the future ICCP Inter-control Center Communications Protocol Standards-based utility data exchange; not proprietary International Standard: (IEC 60870-6-503, IEC 60870-6-802) All major EMS/SCADA vendors have it Designed for system-to-system communication Designed for secure access to restricted data

9 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 9 ICCP MMS & UCA2 MMS ICCP International Standard for Real-Time Messaging ISO/IEC 9506 Data captured in named objects. IEC Standard. Specifies Electric Utility Data Exchange Objects. Blocks for data reqs., security UCA2 Focus on Objects for Substation Automation. Plan: ICCP, UCA. Ethernet LAN/WAN

10 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 1010 LiveData Industrial Enterprise Software Access your information, when and where you need it Lets you leverage existing investments and plan for the future Multi-application view of data Web enabled, database enabled. Rapid deployment Supports ICCP, MMS and UCA2 objects Microsoft Windows NT Y2K Compliant

11 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 1 LiveData Quantum LiveData component runs in Modicon Quantum PLC Hardware module by Schneider Electric The only PLC or ‘RTU’ on the market that supports ICCP and MMS Fiber Optic or Twisted Pair Ethernet Ethernet LAN/WAN Links to Other IEDs in Substation, Other Substations, Control Centers Turns register “data” into network “information” Data object models in the controller

12 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 1212 American Electric Power Goal: Maximum utilization of existing power lines Deferral of new line construction Capital/maintenance cost reduction Deregulated export/import/wheeling of power Unified Power Flow Control (UPFC) Active, real-time power flow control Electric grid equipment in Ohio, Kentucky, Tennessee, Virginia, West Virginia 7 substation sites - only one can accommodate a PC 4 office sites Multiple customer sites Open Communications (MMS) Between substations Substation to control center

13 AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 1313 AEP Architecture Unified Power Flow Control NOENOE NOENOE


Download ppt "AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 1 SCHNEIDER ELECTRIC Solutions."