1. By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt. CE-401 Reinforced Concrete Design-II.

Similar presentations


Presentation on theme: "1. By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt. CE-401 Reinforced Concrete Design-II."— Presentation transcript:

1 1

2 By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt. CE-401 Reinforced Concrete Design-II

3 Course Outline: −Analysis & design of axially loaded columns, Eccentrically loaded columns by USD −Analysis & design of strip footing for wall, spread footings for columns and combined footings by USD. −Design of retaining wall. −Introduction to limit states. −Detailing of reinforcement. −Introduction to design of staircases and water tanks.

4 Columns subjected to eccentric loadings

5

6 Eccentric Compression

7

8

9 Interaction diagrams of combined bending and compression

10

11

12 Behavior under Combined Bending and Axial Loads Interaction Diagram Between Axial Load and Moment ( Failure Envelope ) Concrete crushes before steel yields Steel yields before concrete crushes Any combination of P and M outside the envelope will cause failure. Note:

13 Behavior under Combined Bending and Axial Loads Axial Load and Moment Interaction Diagram – General

14 Behavior under Combined Bending and Axial Loads Resultant Forces action at Centroid ( h/2 in this case ) Moment about geometric center

15 Columns in Pure Tension Section is completely cracked (no concrete axial capacity) Uniform Strain

16 Columns Strength Reduction Factor,  (ACI Code 9.3.2) Axial tension, and axial tension with flexure.  = 0.9 Axial compression and axial compression with flexure. Members with spiral reinforcement confirming to 10.9.3  Other reinforced members  (a) (b)

17 Columns Except for low values of axial compression,  may be increased as follows: when and reinforcement is symmetric and d s = distance from extreme tension fiber to centroid of tension reinforcement. Then  may be increased linearly to 0.9 as  P n decreases from 0.10f c A g to zero.

18 Column

19 Columns Commentary: Other sections:  may be increased linearly to 0.9 as the strain  s increase in the tension steel.  P b

20 Design for Combined Bending and Axial Load (Short Column) Design - select cross-section and reinforcement to resist axial load and moment.

21 Design for Combined Bending and Axial Load (Short Column) Column Types Spiral Column - more efficient for e/h < 0.1, but forming and spiral expensive Tied Column - Bars in four faces used when e/h < 0.2 and for biaxial bending 1) 2)

22 General Procedure The interaction diagram for a column is constructed using a series of values for P n and M n. The plot shows the outside envelope of the problem.

23 General Procedure for Construction of ID − Compute P 0 and determine maximum P n in compression − Select a “c” value (multiple values) − Calculate the stress in the steel components. − Calculate the forces in the steel and concrete,C c, C s1 and T s. − Determine P n value. − Compute the M n about the center. − Compute moment arm,e = M n / P n.

24 General Procedure for Construction of ID − Repeat with series of c values (10) to obtain a series of values. − Obtain the maximum tension value. − Plot P n verse M n. − Determine  P n and  M n. − Find the maximum compression level. − Find the  will vary linearly from 0.65 to 0.9 for the strain values − The tension component will be  = 0.9

25 Example: Axial Load vs. Moment Interaction Diagram Consider an square column (20 in x 20 in.) with 8 #10 (  = 0.0254) and f c = 4 ksi and f y = 60 ksi. Draw the interaction diagram.

26 Example: Axial Load vs. Moment Interaction Diagram Given 8 # 10 (1.27 in 2 ) and f c = 4 ksi and f y = 60 ksi

27 Example: Axial Load vs. Moment Interaction Diagram Given 8 # 10 (1.27 in 2 ) and f c = 4 ksi and f y = 60 ksi [ Point 1 ]

28 Example: Axial Load vs. Moment Interaction Diagram Determine where the balance point, c b.

29 Example: Axial Load vs. Moment Interaction Diagram Determine where the balance point, c b. Using similar triangles, where d = 20 in. – 2.5 in. = 17.5 in., one can find c b

30 Example: Axial Load vs. Moment Interaction Diagram Determine the strain of the steel

31 Example: Axial Load vs. Moment Interaction Diagram Determine the stress in the steel

32 Example: Axial Load vs. Moment Interaction Diagram Compute the forces in the column

33 Example: Axial Load vs. Moment Interaction Diagram Compute the forces in the column

34 Example: Axial Load vs. Moment Interaction Diagram Compute the moment about the center

35 Example: Axial Load vs. Moment Interaction Diagram A single point from interaction diagram, (585.6 k, 556.9 k-ft). The eccentricity of the point is defined as [ Point 2 ]

36 Example: Axial Load vs. Moment Interaction Diagram Now select a series of additional points by selecting values of c. Select c = 17.5 in. Determine the strain of the steel. (c is at the location of the tension steel)

37 Example: Axial Load vs. Moment Interaction Diagram Compute the forces in the column

38 Example: Axial Load vs. Moment Interaction Diagram Compute the forces in the column

39 Example: Axial Load vs. Moment Interaction Diagram Compute the moment about the center

40 Example: Axial Load vs. Moment Interaction Diagram A single point from interaction diagram, (1314 k, 351.1 k-ft). The eccentricity of the point is defined as [ Point 3 ]

41 Example: Axial Load vs. Moment Interaction Diagram Select c = 6 in. Determine the strain of the steel, c =6 in.

42 Example: Axial Load vs. Moment Interaction Diagram Compute the forces in the column

43 Example: Axial Load vs. Moment Interaction Diagram Compute the forces in the column

44 Example: Axial Load vs. Moment Interaction Diagram Compute the moment about the center

45 Example: Axial Load Vs. Moment Interaction Diagram A single point from interaction diagram, (151 k, 471 k-ft). The eccentricity of the point is defined as [ Point 4 ]

46 Example: Axial Load vs. Moment Interaction Diagram Select point of straight tension. The maximum tension in the column is [ Point 5 ]

47 Example: Axial Load vs. Moment Interaction Diagram Pointc (in) P n M n e 1- 1548 k 0 0 220 1515 k253 k-ft 2 in 317.5 1314 k351 k-ft 3.2 in 412.5 841 k500 k-ft 7.13 in 510.36 585 k556 k-ft11.42 in 6 8.0 393 k531 k-ft16.20 in 7 6.0 151 k471 k-ft37.35 in 8~4.5 0 k395 k-ftinfinity 9 0-610 k 0 k-ft

48 Example: Axial Load vs. Moment Interaction Diagram Use a series of c values to obtain the P n verses M n.

49 Example: Axial Load vs. Moment Interaction Diagram Max. compression Max. tension CbCb Location of the linearly varying 

50

51

52

53

54

55 ACI Design Aids for Columns

56 Design Example 8.3

57

58 Bar splicing in Columns

59 Assignment No.1: (Total Marks100 each question carries 50 marks −Design and Rectangular Column to carry dead load of 250K live load of 350K dead load moment 150ft-K and live load moment of 350ft-K Assume material properties. −Determine the main steel required −Determine the ties spacing −Draw final neat to the scale sketch on graph paper − Due Date: Sep,17 2012.