Eusoballoon optics characterisation Camille Catalano and the Toulouse team Test configuration Calibration of the beam Exploration of the focal plan.

Similar presentations


Presentation on theme: "Eusoballoon optics characterisation Camille Catalano and the Toulouse team Test configuration Calibration of the beam Exploration of the focal plan."— Presentation transcript:

1 eusoballoon optics characterisation Camille Catalano and the Toulouse team Test configuration Calibration of the beam Exploration of the focal plan

2 1 - Configuration of the optics tests Typical light source : 390nm LED 1m collimator to create a parallel light beam Typical Incident angle of 3.5° CCD camera + NIST calibrated photodiode used at the focal plan The optics system is composed from only two fresnel lenses

3 2 - Calibration of the collimated beam Scan of the entire beam, calibrated in light power -> 80494±4370 nW (~5% error) Calibration of the beam : Grid pattern placed on the aperture of the instrument ~160 measurements with the NIST

4 Visualisation of the beam with azurins in white paper on the aperture of the instrument -> the photo of the white screen is comparable with the NIST measurements from the NIST mapping of the beam from the photo of the white paper on the aperture 2 - Calibration of the collimated beam

5 3 - Exploration of the focal plan Method : Measurement of the light flux with the NIST along an axis perpendicular with the optical axis Approximation of the encircle energy with the calculation at each position of the integrated flux on a ring of 1cm of thickness (size of the nist = 1cm^2). The integrated flux is then summed with those from the inner rings. Method to approximate the encircle energy collimatorCollimated light beam Optical system NIST measurements along perpendicular axis

6 3 – Exploration of the focal plan Encircle energy with the NIST : e opt = 30.5±3 % Efficiency : (defined as the fraction of the flux collected in the cm 2 centered on the focal spot) Full Width at Half Maximum = ~8mm Scan of the focal plan with the NIST. Blue = direct measurement of the NIST Red = encircle flux λ=391nm θ=3.5° off axis

7 Encircled energy In the central cm2 : e opt = 30.5 % In ~3x3 PDM pixels : e opt = 24 %

8 eusoballoon optics simulation for data analysis Camille Catalano

9 Simulation for data analysis Modeled real object (forest, flasher,…) Simulated data Real data Simulation of the whole instrument

10 Simulation for data analysis Problem : simulation programs didn’t simulate all the diffuse light measured during the optics characterisation Simulation made with ZEMAX

11 Simulation for data analysis A solution : Add artificial scattering on optical surfaces in order to truly reproduce the experimental data Then introduce those changes in the whole instrument simulation My ZEMAX study of artificial scattering in progress…