Presentation is loading. Please wait.

Presentation is loading. Please wait.

CLIQ power supply Integration. General view: -Schroff rack 19’’ 25U (500mm x 600mm x 1120mm). -2 fixed wheels +2 castor wheels with brake ⦰100mm.

Similar presentations


Presentation on theme: "CLIQ power supply Integration. General view: -Schroff rack 19’’ 25U (500mm x 600mm x 1120mm). -2 fixed wheels +2 castor wheels with brake ⦰100mm."— Presentation transcript:

1 CLIQ power supply Integration

2 General view: -Schroff rack 19’’ 25U (500mm x 600mm x 1120mm). -2 fixed wheels +2 castor wheels with brake ⦰100mm.

3 Capacitors bank: 2 Capacitors fixed on a aluminium plate 2 Capacitors fixed on a aluminium plate Rack 19’’fixed on a aluminium plate L shape Aluminium profile to fix capacitors

4 Internal Discharge board:

5 Resistors bank 1.36KΩ 340W 2 “Discharge” relays Bus bars tinned which put the capacitors in parallel Bus bars tinned which put the capacitors in parallel Output voltage connected to thyristors Output voltage Burndy female 7 poles Connected to the control crate Burndy female 7 poles Connected to the control crate

6 Rear panel:

7 Burndy 4 male connector Tigger input Burndy 4 male connector Tigger input Socapex female connector or terminals Weidmuller Output voltage Socapex female connector or terminals Weidmuller Output voltage Filter schaffner 6A Mains circuit breaker Thyristors assembly mounted on a fibber glass isolator on a fibber glass isolator Thyristors assembly mounted on a fibber glass isolator on a fibber glass isolator Burndy 7 poles male Mains input PCB with pulse transformer

8 Crate control:

9 SDS Power supply with Green led “End of charge” Red led “Ucap>40Vdc LCD Current indicator LCD Voltage indicator Selector 0-500V SDS Power supply with Green led “End of charge” Red led “Ucap>40Vdc LCD Current indicator LCD Voltage indicator Selector 0-500V Push button Start charging Push button Start charging Emergency stop Light Mains indicator Light Burndy 7 poles female Power supply output and discharge relays command Burndy 7 poles female Power supply output and discharge relays command Burndy 7 poles male Mains input Burndy 7 poles male Mains input Burndy 4 female Output thyristor command Burndy 4 female Output thyristor command Burndy 4 male Trigger input Burndy 4 male Trigger input

10 Safety aspect: -The power supply is fully closed with special safety screws. -All panels are connected to the earth. -Stickers with warnings are placed on front and back.

11 -2 protection covers with HV warning stickers.


Download ppt "CLIQ power supply Integration. General view: -Schroff rack 19’’ 25U (500mm x 600mm x 1120mm). -2 fixed wheels +2 castor wheels with brake ⦰100mm."

Similar presentations


Ads by Google