GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 1 TART recommendations implementation and qualification program results Alessandro.

Similar presentations


Presentation on theme: "GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 1 TART recommendations implementation and qualification program results Alessandro."— Presentation transcript:

1 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 1 TART recommendations implementation and qualification program results Alessandro Brez INFN - Pisa Brez@pi.infn.it Gamma-ray Large Area Space Telescope

2 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 2 Agenda Summary of the TART recommendations and their implementation Peel test results Test articles description Thermo-vacuum test results Conclusions

3 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 3 TART recommendation 1 Qualification program The qualification program has addressed the recommendations of the TART: Main activities: 1.Tests and analysis of the materials and their compatibility to 3M2216 2.Revision of the assembly procedures and of the assembly environment 3.Construction of 3 tests articles to test different solutions implementing the new procedures in a improved environment 4.Thermo-vacuum tests of the test articles

4 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 4 TART recommendation 2 Tungsten surface preparation Recommendation: Etch the tiles surfaces by MIL-HDBK-961B process (degrease + acid bath) and prime with BR-127 Test the results with peel tests Actions: 2 processes have been investigated: GSFC adopted MIL-HDBK-961B and primed the tiles with BR-127 Vaiarelli (Venaria, Turin) Company process + Plyform BR-127 priming

5 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 5 Tungsten preparation: GSFC results Verify BR-127 Primer Material and Process with lap shear strength tests using 3M2216 and EA9309 Good results close or better than manufacturer declared values with Al 6061 samples and 0.7mm W tiles Check Cleanliness of 100  m W Etched per Modified MIL-HNBK-961B Some silicone contamination on 0.1mm tiles (bags?), no contamination from etched surfaces after 120 o C heating Evaluate HF Etch on 100  m W Very poor peel tests results (~1lb/inch=0.17N/mm). HF etching abandoned Evaluate Kapton Surface Preparation: tests with abraded and unabraded kapton samples Tests in progress Generate Bell test samples Plyfrom style to compare sand blasted tiles results Tests in progress Evaluate ammonium biflouride etch on 100  m W Some 2216 started to fail cohesively but specimens tore in W due to rough edges. Specimens have to be re-made with smooth edges

6 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 6 Tungsten preparation: GSFC analysis of W tiles Tungsten preparation: GSFC analysis of W tiles Analysis Performed by: Debbie Thomas, Code 541/ Swales, 301-286-8577 Figure 3. Cross section of tungsten foil showing “stringers” of included material.~ 200X Stringers Figure 5. SEM photograph of included material. EDS revealed very high carbon, low tungsten content in included material as opposed to tungsten base material Included Material

7 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 7 Tungsten preparation: GSFC analysis of W tiles Figure 6. The photograph on the left was taken on the metallograph (~ 200X) and the one on the right was taken on the SEM. Both show an unusual expansion of the base material (compare the photo on the left to the one in Figure 3 taken at the same magnification). No clear conclusions. The 120 o C bakeout did not reveal extrusion of material from the W tiles. Delamination of the W tiles themselves never observed The anomalies can be related with the synterization process used for W tiles The thick W tiles are from a W alloy (kulite alloy K1750) to have smooth and machinable tiles

8 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 8 materialThickness (mm) Al1.6 Hysol 934A~0.1 W0.1 3M2216~0.1 Kapton0.1 Hysol 934A~0.1 Al0.6 First action: W sand blasting : controlled and uniform roughness of the tiles Qualification test: peel test The debonding pattern at 1mm roughness was better: At Ra=0.5  m film left on Kapton At Ra=1.0  m film left part on Kapton and part on W Tray MID 48 assembled with sand blasted tiles gave acceptable results F 1N/mm~6lb/inch Peel test of sand blasted tiles

9 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 9 Peel tests of Turin etched tiles 4 tests have been performed with etched and primed tiles Results: in 1 case the adhesive layer was left part on W, part on bias circuit. Peel strength=2.1N/mm, comparable with the sand blasted tiles taking into account the different adhesive thickness. In 3 cases there was a complete failure on the Kapton side with rather low and disperse peel strength values (from 0.2 to 1.4 N/mm) 3 tests have been performed with etched tiles without primer. In 2 cases the failure was on kapton side, peel strength=0.8,0.9N/mm In 1 case some of the adhesive, in the central part of the tile, was left on bias circuit. Observed a non uniform glue thickness. Strange pattern. Peel strength=1.4N/mm The sand blasted coupons were cured at RT in normal atmosphere with a not quantified mechanical pressure. Bond thickness 0.1mm. The Kapton foils were not abraded. The etched coupons were cured at RT in a vacuum bag. Bond thickness ~60  m. The Kapton foils were abraded. Conclusions (qualitative) The adhesion of the 3M2216 to the W tiles was generally good The adhesion of the 3M2216 to the Kapton was often bad  need of comparison tests of abraded and unabraded Kapton foils

10 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 10 TART recommendation 3 Bias circuit preparation Roughen surface with Scotch Brite pads until sheen is removed Clean (acetone wipe + IPA wipe) Bake 60oC for 12hours Clean (acetone wipe + IPA wipe) Wait 30 min Bond The process has been implemented in Plyform (INFN_LAT_MECH_008_2) After the ambiguous results of peel the tests 2 sets of peel tests coupons have been prepared with abraded and unabraded kapton foils glued on Al specimens with 3M2216. Peel strenght of unabraded samples = 1.1N/mm  0.5N/mm Peel strenght of abraded samples = 3.5N/mm  0.35N/mm

11 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 11 TART recommendation 4,5 Tungsten bonding The recommendation describes in details the W tile bond process and the preparation of the adhesive with degassing. The recommendations have been implemented INFN_LAT_MECH_009_02Adhesive preparation INFN_LAT_MECH_006_02Tungsten and bias circuit bonding

12 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 12 TART recommendation 6 Grounding of Tungsten tiles MCM front Grounded tile Not grounded tile Test article 2 Planarity 224  m A wire sticks out from the tray after gluing Aluminum gold plated 55  m wires Test article 2 Planarity 170  m Test article 2 Planarity 139  m A wire sticks out from the tray after gluing Conclusions: The system does not guarantee the tiles grounding The vacuum extracts the wires to the edge of the tray, very dangerous! The wires seem to compromise the final planarity of the tray

13 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 13 Do we need W tiles grounding? GFSC primed W tile 0.06mm 3M2216 film (cured 15h at 40 o C) Al base A Keythley 467 V I Breakdown to 1.4K  C=6nF R=~1G  at 1V  ~6s Any buildup charge will disappear in few seconds

14 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 14 TART recommendation 7,8 Process cleanliness, QA control A detailed list of manufacturing rules have been dictated. These rules have been incorporated in INFN-LAT-MECH-007-01 INFN personnel made detailed revision of all the Istruzioni di Lavoro (Work Instructions) and will directly overlook the construction of the first trays. The real main effort to satisfy the request of a clean area insulated from the rest of the Plyform activities, has been the purchase of a clean-tent dedicated to GLAST tray assembly. The tent will be ready to work on October 4 th. Mandatory inspection points have been introduced: 1.Tile cleanliness and priming with routinely peel results 2.Kapton preparation 3.Adhesive preparation and deposition with hardness tests

15 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 15 TART recommendation 9 Non use of grid blasted tungsten The 0.1mm sand blasted tiles are no more flat. We cannot use them in any case  segregated steel vacuum chucks tray Bias circuit 3M2216 A possible cause of bubbles: The Kapton is hold flat by the tool during adhesive curing. A local depression of the tray surface (50  m or more) could cause a bridge effect Proposed solution: Add a compliant pad between tool and bias circuit to compensate the tray irregularities. A suitable material has not found up to now. The test of this solution will be addressed again if needed. TART recommendation 10 Bond joint compression

16 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 16 TART recommendation 11 Alternate bond cure protocol Cure the 3M2216 adhesive at 35 o C in a oven for 18hours Pro: Better controlled cure cycle. The whole cure cycle is under vacuum. At the beginning the adhesive is more fluid + higher temperature => better outgassing Contra: Possible deformation of the tray due to CTE mismatch 2 test articles have been produced at 35 o C

17 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 17 TART recommendation 12 Examine bonding integrity of the EM tower Only one tray of the EM tower is representative: The TOP TRAY has the W thin tiles + the final version of the bias circuit, with the continuous Cu layer insulated by a smooth Kapton layer. The TOP EM tray is equipped with dummy ladders After the optical inspection, taping the tray and the ESPI test, we had NO evidence of defects 726Hz, first tray resonance mode 1251Hz, Second tray resonance mode 2443Hz, first ladder resonance mode

18 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 18 Test articles Test temp. ( o C) 45 o C 50 o C 55 o C 60 o C 65 o C 70 o C 75 o C Test duration (h) 1h10’3h12h3h Thermo-vacuum cycles (P<10 - 2mBar, min P=50  bar) Test article#1 MID045#2 MID042#3 MID049 To etchingYYY PrimerYYN Cure temp.RT35 o C Notes An operator error in top bias circuit assembly caused a misalignment of the bias circuit and a not perfect adhesion

19 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 19 Top faces behavior Top faces behavior Very good results of bias circuit adhesion on face sheet up to 75 o C

20 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 20 Bottom face #3 NO primer 60 o C development of a Ø25mm delamination 65 o C debonding over 3 whole tiles 70 o C one more tile debonded Perfect clean W tile Very good and uniform 3M2216 film on bias circuit Very good adhesion to the previous glue layer (no Frecot55 pollution)

21 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 21 Bottom face #1 primer RT

22 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 22 Bottom face #2 primer 35 o C The best result in terms of n. of little bubbles and temperature stability

23 GLAST LAT ProjectOctober 1st, 2004 GLAST LAT Tracker Anomaly Resolution Team 23 TART qualification program indications The best results have been obtained with the configuration These options + the specific procedures to match the TART recommendations are included in the LAT-DS-01584 procedure