1 AFC Module Meeting Friday - May 21, 2004 Report on the Window burst test Edgar Black IIT

2 MTA Absorber Design Progress This windows are of a nominal 21cm diameter The diameter was selected to fit on the forced flow absorber inside the 40cm. diameter magnet bore (lab G magnet) The design called for 25psi MOP and rupture up to 100psi The bellow type new configuration was aimed to achieve a minimum of 105 micron thickness at the center Data from the burst test on this window will be used to verify the window design parameters for MICE

3 Fabricated window design details

4 Window profile parameters

5 Manifold construction detail

6 Back plate for pressure test

7 Receiving window inspection CMC report (partial sample) the holes and the plane on right side. Bolt circle constructed of points of intersection between DIM BOLT CIRCLE OF HOLES ON RT SIDE= LOCATION OF CIRCLE B.C.RT SIDE UNITS=MM AX MEAS X 0.00000 Y 0.00000 Z 0.00000 D 218.02053 RN 0.04067 Holes measured as cylinders, starting with the hole at 90 deg and going anti-clockwise. Measurements shown are Polar Radius, Polar Angle, Diameter and Vectors I,J,K. DIM HOLE AT 90 DEG= LOCATION OF CYLINDER RT 90 HOLE UNITS=MM AX MEAS PR 108.98744 PA 89.98625 D 3.21533 V -0.00063 -0.00067 1.00000 0.00000 DIM RND1= ROUNDNESS OF CYLINDER RT 90 HOLE UNITS=MM AX MEAS M 0.10550 DIM HOLE AT 150 DEG= LOCATION OF CYLINDER CYL1 UNITS=MM AX MEAS

8 Measurements results Photogrametry technique give the minimum thickness to be 190 microns Gauged thickness on the burst window material at the center measured 101 microns The above measurements included 15 micron total of the material (spray paint) coating both sides of the window Donald Summers reported a central thickness of 117 microns (no paint)

9 Burst test No fatal events as predicted, a safety analysis was submitted before the test for approval Pressure was apply to the window/plate volume on increments of 5psig A leak developed over the elastomer gasket at 133psig Changed the gasket 2.5mm instead of.8mm diameter plus vacuum grease Repeated test, burs pressure at 144psig