Presentation is loading. Please wait.

Presentation is loading. Please wait.

Application of the Beta-ray alignment for the OPERA CSDs Seigo Miyamoto.

Similar presentations


Presentation on theme: "Application of the Beta-ray alignment for the OPERA CSDs Seigo Miyamoto."— Presentation transcript:

1 Application of the Beta-ray alignment for the OPERA CSDs Seigo Miyamoto

2 Beta-ray alignment New alignment method by using beta- ray from environmental radioactive isotopes. Coincidence at contacted emulsion layers. Effective to correct the distortion( is essential for good position resolusion) of film by development or drying.

3

4 Detection of position displacement peak of beta-ray -Take all combination of dx in ~+-100um - Angle allowance is FREE. 2.1um 1.8um

5 If the tightness of packing is enough, Position displacement of high energy tracks from beta-ray alignment peak (um)

6 Application for the OPERA CSD Alignment accuracy is less than 1um. Effective to reject BG tracks very much. Samples : Cosmic run events ---- 26 CSDs Neutrino events ---- 32 CSDs

7 At first, division of area (5mm x 5mm)

8 Procedure Taking all combinations of MicroTracks in contacted layers, And Detection of beta-ray alignment peaks in each unit areas. Position displacement distribution from the X-ray alignment

9 40 um 20um in delta position space Plot vector as the center of peak in each unit area on the film map -> Relative Distortion map.

10 Some Samples

11

12

13

14

15 Estimation of successful area Continuity check is suitable which beta-ray alignment is success or not because distortion should be continual. -Check the difference of vector between adjacent area. -For example, d(dX)(a,b)=dX b -dX a - if d(dX) =2 adjacent areas, “a” is defined as continual(successful). b a c d e

16 beta-ray alignment summary

17 Continual area ratio of CSDs sucessful

18 The reason of below 90% Not enough beta-rays to align. ---- 1 Peak is detected, but double. ---- 5 Large Gap exists. ---- 1

19 Examples, Double Peak

20

21

22

23 Examples, Large Gap is Detected.

24

25

26 Summary Beta-ray alignment was applied to real OPERA Experiment. The number of beta-ray for alignment is enough. We estimated mechanical tightness. 26/32 CSDs is aligned successfully. 5/32 CSDs have Double Peaks, these are recoverable by detection both (We have 2 alignments, BG Doublet tracks become twice). 1/32 CSD has large (more than 100um) gap, we can detect it. We continue the study of these 6 events.