Presentation is loading. Please wait.

Presentation is loading. Please wait.

OLYMPUS Collaboration Meeting Cooling Water David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010.

Similar presentations


Presentation on theme: "OLYMPUS Collaboration Meeting Cooling Water David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010."— Presentation transcript:

1 OLYMPUS Collaboration Meeting Cooling Water David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

2 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting2 1.– Starting Data 2.– OLYMPUS – BLAST Water 3.- Pressure Reduction 4.- Supply Power Cable Cooling 5.- Summary

3 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting3

4 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting4

5 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting5 10 bars Pressure 70 m 3 /h Flow 200 mm Diameter

6 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting6 168,3 mm Diameter Some Flanges Available More Pipes Needed

7 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting7 2.– OLYMPUS – BLAST Water

8 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting8 Water Enters this Side

9 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting9 2 OUTs Manifold Distributes Water 1 IN

10 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting10 Distributing Manifolds

11 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting11 Water to Manifolds Space Available at DESY Pit: Alignment of the Tank Thread with Pipes Going to Manifolds

12 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting12 Shift Tank Thread

13 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting13 Double Water Circuit (In – Out) Connection with Tank Thread Separated Circuit for Mounting-Beam Position

14 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting14 1 Tee 2 Valves

15 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting15 3.- Pressure Reduction

16 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting16 Restriction Orifice Plate From 10 to 8 Bars

17 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting17 Screw 7 to 8 bar 10 bar d ~ 38 – 41 mm Water Pressure Reduction FEASIBLE Water Flow: To Be Checked Pressure Release Valve

18 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting18 4.- Supply Power Cable Cooling

19 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting19 BLAST: Cooling of Cables Going to the Coils

20 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting20 Needed for OLYMPUS?

21 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting21 Summary - Layout of the Pipes Circuit Done - More Pipes Needed - BLAST Pipes and Fittings Available - Separated Circuits for Mounting-Beam Position - Orifice Plate for Pressure Reduction - Water Flow to Be Checked - Supply Power Cable Cooling Needed?

22 Cooling Water 23/02/2010David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting22 Personal Contact: d.rodriguezpineiro@gsi.de Tel: +49 (0) 6159171/1634 web.mit.edu/OLYMPUS Thank you!