Presentation is loading. Please wait.

Presentation is loading. Please wait.

Transient Heat Transfer of Automobile A/C System Prepared by: Jason Hixson, Don Scott, and Michael Hickey August 29, 2005.

Similar presentations


Presentation on theme: "Transient Heat Transfer of Automobile A/C System Prepared by: Jason Hixson, Don Scott, and Michael Hickey August 29, 2005."— Presentation transcript:

1 Transient Heat Transfer of Automobile A/C System Prepared by: Jason Hixson, Don Scott, and Michael Hickey August 29, 2005

2 A/C Schematic Recycled AirCooled Air R-134a M 2,T 2 M 1, T 1 M 3,T 3 M 4,T 4 R-134a

3 Objectives Measure temperatures & velocities of cooled air. Perform material and energy balance. Measure temperature of recycled air. Make estimates of coolant temperatures. Make estimates of air volume in car. Observe pseudo steady-state transient behavior.

4 The Energy Balance: Air Side: ∆H=m 2 *C p (T 2 -T 1 ) ∆H=UA ∆T lm Refrigerant Side: ∆H=m 3 (H 4 -H 3 )

5 Variables & Assumptions Entrance temperature Exit temperature Fan speed Velocity Engine RPM Time C p =1.004 kJ/kg*K H 3 =17.14 kJ/kg H 4 =234.15 kJ/kg T 3 =T 4 =40 °C

6

7

8

9

10

11 Quick Facts Fan setting 4 was unable to lower car temperature. R-134a mass flow rate is dependant on engine rpm. Air mass flow rate is not affected by engine rpm. Cab volume=2.3 m 3 Traveling at 2000 rpm, maximum heat transfer will occur at fan setting 3 where: UA=0.3 kJ/°C m 1 =0.13 kg/s


Download ppt "Transient Heat Transfer of Automobile A/C System Prepared by: Jason Hixson, Don Scott, and Michael Hickey August 29, 2005."

Similar presentations


Ads by Google