Presentation is loading. Please wait.

Presentation is loading. Please wait.

GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 1 The GLAST Silicon Tracker Marcus Ziegler Santa Cruz Institute for Particle Physics University.

Similar presentations


Presentation on theme: "GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 1 The GLAST Silicon Tracker Marcus Ziegler Santa Cruz Institute for Particle Physics University."— Presentation transcript:

1 GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 1 The GLAST Silicon Tracker Marcus Ziegler Santa Cruz Institute for Particle Physics University of California at Santa Cruz GLAST LAT Collaboration ziegler@scipp.ucsc.edu Gamma-ray Large Area Space Telescope

2 GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 2 GLAST LAT Overview e+e+ e–e–  Si Tracker 8.8  10 5 channels 155 Watts 3000 kg, 650 W (allocation) 1.8 m  1.8 m  1.0 m Effective area ~1 m 2 CsI Calorimeter 8.4 radiation lengths 8 × 12 bars ACD Veto Counters Segmented scintillator tiles

3 GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 3 Tracker Construction- Overview Kapton readout cables. 18 19 “trays” stack to form one of 16 Tracker modules. 342 Electronics mount on the tray edges. “Tray” 648 Chip-on-board readout electronics modules. Composite panels, with tungsten foils bonded to the botom face. 342 Tested SSDs procured from Hamamatsu Photonics 4 SSDs bonded in series. 2592 10,368

4 GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 4 Silicon Strip Detector  ~80 m 2 of PIN diodes, with P implants segmented into narrow strips.  Reliable, well-developed technology from particle- physics applications.  Leakage current < 2.5 nA/cm 2  Bad channels < 1/10,000  Full depletion < 100 V. 8.95 cm square Hamamatsu-Photonics SSD before cutting from the 6-inch wafer. The thickness is 400 microns, and the strip pitch is 228 microns.

5 GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 5 Silicon detector GTFE GTRC Binary readout Redundancy scheme Zero suppression Readout Electronics on the Tray

6 GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 6 Readout Electronics Based on 2 ASICs developed exclusively for this project:  64-channel amplifier-discriminator chip (GTFE); 24 per module.  Readout controller chip (GTRC); 2 per module.

7 GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 7 Pulse shape and calibration

8 GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 8 Minitower for taking cosmics data Thanks to Hiro Tajima and Eduardo do Couto e Silva

9 GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 9 Hitmap with Cosmics for three Trays

10 GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 10 Efficiency for cosmic rays


Download ppt "GLAST LAT Silicon Tracker Marcus ZieglerAPS April Meeting 2004 1 The GLAST Silicon Tracker Marcus Ziegler Santa Cruz Institute for Particle Physics University."

Similar presentations