Presentation is loading. Please wait.

Presentation is loading. Please wait.

3D Simulations-- the vertical dimension. Representation of hydrogeologic units in MODFLOW88.

Similar presentations


Presentation on theme: "3D Simulations-- the vertical dimension. Representation of hydrogeologic units in MODFLOW88."— Presentation transcript:

1 3D Simulations-- the vertical dimension

2 Representation of hydrogeologic units in MODFLOW88

3 MODFLOW2000

4 In MODFLOW, vertical flow between layers Is governed by vertical conductance.

5 Horizontal Conductance Review

6 Vertical Conductance Terms VCONT = K v /  z = leakance or VCONT = Vertical Conductance / (  x  y) If Kv and  z are constants

7 Vertical Conductance Terms VCONT = K v /  z = leakance = Vertical Conductance / (  x  y) MODFLOW uses special terms (VCONT) to calculate vertical conductance between layers. VCONT values are required in 3D problems. Modflow.exe requires the user to supply values for the VCONT arrays. GW Vistas gives you the option to input the VCONT values, called leakance in GWV, or will compute the values in the VCONT arrays for you.

8 3 layers K= constant =30 m/day 20 m 60 m 20 m L=30/20 L=0 L=30/40 Calculation of leakance for a simple example

9 Leakance between layers where each Layer belongs to a different hydrogeologic unit See A&W, p. 81

10 Leakance between layers where both layers belong to the same hydrogeologic unit See A&W, p. 81

11 “Quasi 3D” Models The effects of confining layers are simulated using leakance terms. The confining layers are not physically represented as model layers. Confining layer

12 8 layer model Example

13 Quasi 3D design – 2 layer model

14 Leakance “Quasi 3D” model See A&W, p. 81

15 980 1000 3D design of the Hubbertsville Problem Raycine’s Problem Three layers 1000 Leakance = K v /  z 1 2 3 Layer 1 = 50/10 Layer 2 = 50/10 Layer 3 = 0 990 But leakance should be calculated based on the saturated thickness of the cell. 1010

16 from GWV

17 Remember: In MODFLOW, a layer is considered “confined” when the head in the cell is above the top of the cell. (If the top layer is specified to be unconfined, it has no top elevation.)

18 3D design of the Hubbertsville Problem Three layers with well nodes in each layer 1000 1 2 3 Need to apportion total well discharge of 20,000 over 3 layers with 20,000/3 to each layer. But then, cells in the top layer go dry and MODFLOW shuts off the well. When this happens the total discharge is less than 20,000.

19 3D design of the Hubbertsville Problem Three layers with well nodes in two layers 1000 1 2 3 Apportion total well discharge of 20,000 to the bottom 2 layers with 10,000 to each layer. Now, heads in layers 2 and 3 are similar to heads in the 2D (one layer) version of the problem.


Download ppt "3D Simulations-- the vertical dimension. Representation of hydrogeologic units in MODFLOW88."

Similar presentations


Ads by Google