Presentation is loading. Please wait.

Presentation is loading. Please wait.

Instructions for using this template. Remember this is Jeopardy, so where I have written “Answer” this is the prompt the students will see, and where.

Similar presentations


Presentation on theme: "Instructions for using this template. Remember this is Jeopardy, so where I have written “Answer” this is the prompt the students will see, and where."— Presentation transcript:

1

2 Instructions for using this template. Remember this is Jeopardy, so where I have written “Answer” this is the prompt the students will see, and where I have “Question” should be the student’s response. To enter your questions and answers, click once on the text on the slide, then highlight and just type over what’s there to replace it. If you hit Delete or Backspace, it sometimes makes the text box disappear. When clicking on the slide to move to the next appropriate slide, be sure you see the hand, not the arrow. (If you put your cursor over a text box, it will be an arrow and WILL NOT take you to the right location.)

3 Click here for Final Jeopardy

4

5 Safety IPM’s for Rodents IPM’s for Rodents FMP’s for Rodents FMP’s for Rodents 1 Point 2 Points 3 Points 4 Points 5 Points 1 Point 2 Points 3 Points 4 Points 5 Points 3 Points 4 Points 5 Points EPA Rule Changes EPA Rule Changes Structural Fumigation Structural Fumigation

6 Aluminum Phosphide must be transported to the jobsite in an approved container. (True or False)

7 True

8 Zinc Phosphide is a Restricted use Fumigant and requires a License to purchase. (True or False)

9 False

10 Monitoring these readings are required when using Aluminum Phosphide.

11 What is Fumigant Concentration Readings?

12 The lowest grain temperature allowed when using aluminum phosphide is.

13 41 Degrees Fahrenheit

14 The formula for finding the volume of a cylinder.

15 3.14 x radius squared x height

16 Name of the area around rodent fumigant application which bystanders and pedestrians must be kept out

17 What is the Buffer Zone?

18 The fumigant gas which smells like garlic.

19 What is phosphine?

20 An applicator, to qualify for wearing respiratory equipment does

21 What are fit test, equipment training, and determined to be physically fit to wear respirator?

22 You need to wear this is concentrations of aluminum phosphide exceed 15 ppm.

23 SCBA

24 5 of the symptoms of exposure to a fumigant

25 What are: Slowed body movements Slurred/slowed speech Dizziness Numbness of hand or feet Coughing Sneezing Nausea Abdominal pain Stimulate drunkenness ?

26 Applications of aluminum phosphide strictly prohibited

27 What are single and multi- family residential properties, nursing homes, schools, day care centers, hospitals?

28 The lower flammable limit of a/p.

29 What is 18,000 ppm?

30 The Short-term exposure limit (STEL) for a/p.

31 What is 1 ppm?

32 Minimum distance from a building where applications of a/p may be made.

33 What is 100 ft?

34 The maximum application rate for burrowing rodents

35 What is 10-20 pellets?

36 Cultural practices that can affect rodent numbers

37 What are – soil tillage/cultivation, crop rotation, irrigation, burning, grazing mgmt?

38 Two types of fumigant used to control rodents

39 What are – ignitable gas cartridges and aluminum phosphide?

40 Prebaiting is necessary for which rodenticide bait

41 What is – Zinc Phosphide

42 The number of applications and time between applications required for Rozol rodenticide baits

43 What is - 2 applications 2 – 3 days apart?

44 Additional information on aluminum and magnesium phosphide can be found at this site

45 What is the EPA website? epa.gov/oppsrrd1/reregistration/alphosphide/

46 When should a Rodent Fumigation Management Plan (FMP) be completed? When should a Rodent Fumigation Management Plan (FMP) be completed?

47 What is - Prior to fumigant application.

48 Is 15-100 ft an acceptable distance from buildings that humans or domestic animals inhabit that Aluminum Phosphide can be applied (True or False)

49 False

50 A commercial applicator applying aluminum phosphide fumigant must provide a copy of the completed FMP to

51 Who is – the customer?

52 Information required on a placards which should be placed at all fumigation sites

53 What are – the signal word DANGER/PELIGRO, skull and crossbones, name and EPA registration number of the fumigant, and a 24 hour Emergency Response number?

54 Timeframe before application for applicators to provide information directly to neighbors?

55 What is 48 hours?

56 Make your wager

57 7 Difficult to Evacuate Sites

58 What are: -Schools (Pre-K - 12) -State licensed daycare centers -Nursing homes -Assisted living facilities -Hospitals -In-patient clinics -Prisons?


Download ppt "Instructions for using this template. Remember this is Jeopardy, so where I have written “Answer” this is the prompt the students will see, and where."

Similar presentations


Ads by Google